Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 322

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Summary of Results Using the Nucleus CI24M Implant to Record the Electrically Evoked Compound Action Potential

Abbas, Paul J., Brown, Carolyn J., Shallop, Jon K., Firszt, Jill B., Hughes, Michelle L., Hong, Sung H., Staller, Steven J. · 1999 · Ear and Hearing

Abstract

OBJECTIVE: This study outlines a series of experiments using the neural response telemetry (NRT) system of the Nucleus CI24M cochlear implant to measure the electrically evoked compound action potential (EAP). The goal of this investigation was to develop a protocol that allows successful recording of the EAP in a majority of CI24M cochlear implant users. DESIGN: Twenty-six postlingually deafened adults participated in this study. A series of experiments were conducted that allowed us to examine how manipulation of stimulation and recording parameters may affect the morphology of the EAP recorded using the Nucleus NRT system. RESULTS: Results of this study show consistent responses on at least some electrodes from all subjects. Cross-subject and cross electrode variations in both the growth of the response and the temporal refractory properties of the response were observed. The range of stimulus and recording parameters that can be used to record the EAP with the Nucleus NRT system is described. CONCLUSIONS: Using the protocol outlined in this study, it is possible to reliably record EAP responses from most subjects and for most electrodes in Nucleus CI24M cochlear implant users. These responses are robust and recording these responses does not require that the subject sleep or remain still. Based on these results, a specific protocol is proposed for measurement of the EAP using the NRT system of the CI24M cochlear implant. Potential clinical implications of these results are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003446-199902000-00005

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 322

Metadata

Authors
Abbas, P. J., Brown, C. J., Shallop, J. K., Firszt, J. B., Hughes, M. L., Hong, S. H., & Staller, S. J.
Venue
Ear and Hearing
Published
1999-02
Volume
20
Issue
1
Pages
45-59
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2066845395
Cited by
322
References
13
FWCI
6.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Summary of Results Using the Nucleus CI24M Implant to Record the Electrically Evoked Compound Action Potential. https://app.cochat.ai/papers/10.1097/00003446-199902000-00005
The paper
Abbas, P. J., Brown, C. J., Shallop, J. K., Firszt, J. B., Hughes, M. L., Hong, S. H., & Staller, S. J. (1999). Summary of Results Using the Nucleus CI24M Implant to Record the Electrically Evoked Compound Action Potential. Ear and Hearing. https://doi.org/10.1097/00003446-199902000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.