Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 271

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

A Longitudinal Study of Electrode Impedance, the Electrically Evoked Compound Action Potential, and Behavioral Measures in Nucleus 24 Cochlear Implant Users

Hughes, Michelle L., Vander Werff, Kathy R., Brown, Carolyn J., Abbas, Paul J., Kelsay, Danielle M. R., Teagle, Holly F. B., Lowder, Mary W. · 2001 · Ear and Hearing

Abstract

OBJECTIVE: The primary goal of this study was to examine changes that may occur in electrode impedance, electrically evoked compound action potential (EAP) threshold and slope of the EAP growth function, and behavioral measures of threshold T-level) and maximum comfort (C-level) over time in both adult and child cochlear implant users. Secondary goals were to determine whether changes in these measures are consistent between children and adults, and to determine whether behavioral measures (MAP T- and C-levels) and electrophysiologic measures (EAP thresholds) exhibit the same trends over time. DESIGN: Thirty-five children and 33 adults implanted with the Nucleus CI24M between November 1996 and August 1999 participated in this study. Subjects were included in this study if 1) they had used their implant for at least 1 yr after device connection, and 2) they had participated in the necessary data collection at a minimum number of the time intervals assessed in this study. EAP threshold, slope of the EAP growth function, and common ground electrode impedance measures were collected intraoperatively, at initial stimulation, and at several subsequent visits up to 2 yr post initial stimulation. MAP T- an d C-levels weremeasured at initial stimulation and at the same time intervals as described above. RESULTS: Changes in electrode impedance, EAP thresholds, and slope of the EAP growth function from measures made intraoperatively, at initial stimulation, and at 1 to 2 mo post initial stimulation were similar in both children and adults. Beyond the 1- to 2-mo visit, children exhibited significant increases in electrode impedance, EAP thresholds, slope, and MAP T-levels, whereas these samemeasures in adults remained relatively stable. EAP thresholds in children stabilized by the 3- to 8-mo visit, and electrode impedance stabilized by the 6- to 8-mo visit, while slope of the EAP growth function, MAP T-levels,and MAP C-levels werestable by 1 yr post initial stimulation. C-levels in adults increased up to 1 yr post initial stimulation; however, the amount of increase was much smaller than that seen in children. In both children and adults, longitudinal trends in EAP thresholds mirrored T-level more closely than C-level. CONCLUSIONS: The results of this study suggest that peripheral changes occur in many children that do not generally occur in adults within the first year of cochlear implant use. One implication of these results is that if EAP thresholds are to be used to assist in programming the speech processor for children, it is best to make those measures at the same time interval as device programming rather than using measures made intraoperatively or at the initial programming session to set MAP levels at later visits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003446-200112000-00004

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 271

Metadata

Authors
Hughes, M. L., Vander Werff, K. R., Brown, C. J., Abbas, P. J., Kelsay, D. M. R., Teagle, H. F. B., & Lowder, M. W.
Venue
Ear and Hearing
Published
2001-12
Volume
22
Issue
6
Pages
471-486
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2044326168
Cited by
271
References
17
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Longitudinal Study of Electrode Impedance, the Electrically Evoked Compound Action Potential, and Behavioral Measures in Nucleus 24 Cochlear Implant Users. https://app.cochat.ai/papers/10.1097/00003446-200112000-00004
The paper
Hughes, M. L., Vander Werff, K. R., Brown, C. J., Abbas, P. J., Kelsay, D. M. R., Teagle, H. F. B., & Lowder, M. W. (2001). A Longitudinal Study of Electrode Impedance, the Electrically Evoked Compound Action Potential, and Behavioral Measures in Nucleus 24 Cochlear Implant Users. Ear and Hearing. https://doi.org/10.1097/00003446-200112000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.