The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The Relationship Between EAP and EABR Thresholds and Levels Used to Program the Nucleus 24 Speech Processor: Data from Adults
Abstract
OBJECTIVE: The objective of this study was to determine the relationship between electrically evoked whole nerve action potential (EAP) and electrical auditory brain stem response (EABR) thresholds and MAP threshold (T-level) and maximum comfort level (C-level) for subjects who use the Nucleus 24 cochlear implant system. DESIGN: Forty-four adult Nucleus 24 cochlear implant users participated in this study. EAP thresholds were recorded using the Neural Response Telemetry System developed by Cochlear Corporation. EABR thresholds were measured for a subset of 14 subjects using standard evoked potential techniques. These physiologic thresholds were collected on a set of five electrodes spaced across the cochlea, and were then compared with behavioral measures of T-level and C-level used to program the speech processor. RESULTS: EAP thresholds were correlated with MAP T- and C-levels; however, the correlation was not strong. A technique for improving the correlation by combining measures of T- and C-levels made on one electrode with the EAP thresholds was presented. Correlations between predicted and measured T- and C-levels using this technique were 0.83 and 0.77, respectively. Similar results were obtained using the EABR thresholds for a smaller set of subjects. In general, EABR thresholds were recorded at levels that were approximately 4.7 programming units lower than EAP thresholds. CONCLUSIONS: Either EAP or EABR thresholds can be used in combination with a limited amount of behavioral information to predict MAP T- and C-levels with reasonable accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abbas, P. J., Brown, C. J., Shallop, J. K., Firszt, J. B., Hughes, M. L., Hong, S. H., & Staller, S. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00005 · Cited by 322
Self-citationElectrically evoked whole-nerve action potentials: Data from human cochlear implant users
Brown, C. J., Abbas, P. J., & Gantz, B. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399716 · Cited by 303
Self-citationPreliminary experience with neural response telemetry in the nucleus CI24M cochlear implant.
Brown, C., Abbas, P. J., & Gantz, B. J. (1998) · PubMed · Cited by 127
Self-citationBrown, C., Abbas, P. J., Fryauf-Bertschy, H., et al. (1994) · Ear and Hearing · doi:10.1097/00003446-199404000-00006 · Cited by 110
Self-citationBrown, C., Abbas, P. J., Borland, J., & Bertschy, M. (1996) · Journal of Speech Language and Hearing Research · doi:10.1044/jshr.3903.453 · Cited by 102
Self-citation
Cited by
Hughes, M. L., Vander Werff, K. R., Brown, C. J., Abbas, P. J., Kelsay, D. M. R., Teagle, H. F. B., & Lowder, M. W. (2001) · Ear and Hearing · doi:10.1097/00003446-200112000-00004 · Cited by 271
Self-citationCochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
Visram, A. S., Innes-Brown, H., El-Deredy, W., & McKay, C. M. (2015) · Hearing Research · doi:10.1016/j.heares.2015.04.012 · Cited by 54
Deprez, H., Gransier, R., Hofmann, M., van Wieringen, A., Wouters, J., & Moonen, M. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2622979 · Cited by 15
Guenser, G., Laudanski, J., Phillipon, B., Backus, B. C., Bordure, P., Romanet, P., & Parietti-Winkler, C. (2015) · Cochlear Implants International · doi:10.1179/1754762814y.0000000082 · Cited by 11
Metadata
- Authors
- Brown, C. J., Hughes, M. L., Luk, B., Abbas, P. J., Wolaver, A., & Gervais, J.
- Venue
- Ear and Hearing
- Published
- 2000-04
- Volume
- 21
- Issue
- 2
- Pages
- 151-163
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2023088562
- Cited by
- 275
- References
- 5
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relationship Between EAP and EABR Thresholds and Levels Used to Program the Nucleus 24 Speech Processor: Data from Adults. https://app.cochat.ai/papers/10.1097/00003446-200004000-00009
- The paper
- Brown, C. J., Hughes, M. L., Luk, B., Abbas, P. J., Wolaver, A., & Gervais, J. (2000). The Relationship Between EAP and EABR Thresholds and Levels Used to Program the Nucleus 24 Speech Processor: Data from Adults. Ear and Hearing. https://doi.org/10.1097/00003446-200004000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.