The DOI matches its Crossref record.
Comparison of EAP Thresholds with MAP Levels in the Nucleus 24 Cochlear Implant: Data from Children
Abstract
OBJECTIVE: The purpose of this study is to examine the relationship between the electrically evoked compound action potential (EAP) thresholds and the MAP thresholds (T-levels) and maximum comfort levels (C-levels) in children implanted with the Nucleus 24 device. DESIGN: EAP thresholds were measured using the Neural Response Telemetry system of the Nucleus 24 device. Twenty children implanted with the Nucleus 24 cochlear implant participated in this study. EAP thresholds were compared with the behavioral measures of T- and C-level used to construct the MAP these children used on a daily basis. For these subjects, both EAP and MAP T- and C-levels were obtained the same visit, which occurred at 3 to 5 mo postconnection. RESULTS: EAP thresholds were shown to fall between MAP T- and C-level for 18 of 20 subjects tested; however, considerable variability across subjects was noted. On average, EAP thresholds fell at 53% of the MAP dynamic range. Correlations between EAP threshold and MAP T- and C-level improved substantially when combined with behavioral measures obtained from one electrode in the array. CONCLUSIONS: Moderate correlations were found between EAP thresholds and MAP T- and C-levels for the children participating in this study. However, a technique is described for improving the accuracy of predictions of MAP T- and C-levels based on EAP data combined with a small amount of behavioral information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hughes, M. L., Vander Werff, K. R., Brown, C. J., Abbas, P. J., Kelsay, D. M. R., Teagle, H. F. B., & Lowder, M. W. (2001) · Ear and Hearing · doi:10.1097/00003446-200112000-00004 · Cited by 271
Self-citationCan ECAP measures be used for totally objective programming of cochlear implants?
McKay, C. M., Chandan, K., Akhoun, I., Siciliano, C., & Kluk, K. (2013) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-013-0417-9 · Cited by 81
Visram, A. S., Innes-Brown, H., El-Deredy, W., & McKay, C. M. (2015) · Hearing Research · doi:10.1016/j.heares.2015.04.012 · Cited by 54
Deprez, H., Gransier, R., Hofmann, M., van Wieringen, A., Wouters, J., & Moonen, M. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2622979 · Cited by 15
Guenser, G., Laudanski, J., Phillipon, B., Backus, B. C., Bordure, P., Romanet, P., & Parietti-Winkler, C. (2015) · Cochlear Implants International · doi:10.1179/1754762814y.0000000082 · Cited by 11
Metadata
- Authors
- Hughes, M. L., Brown, C. J., Abbas, P. J., Wolaver, A. A., & Gervais, J. P.
- Venue
- Ear and Hearing
- Published
- 2000-04
- Volume
- 21
- Issue
- 2
- Pages
- 164-174
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2014766277
- Cited by
- 185
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of EAP Thresholds with MAP Levels in the Nucleus 24 Cochlear Implant: Data from Children. https://app.cochat.ai/papers/10.1097/00003446-200004000-00010
- The paper
- Hughes, M. L., Brown, C. J., Abbas, P. J., Wolaver, A. A., & Gervais, J. P. (2000). Comparison of EAP Thresholds with MAP Levels in the Nucleus 24 Cochlear Implant: Data from Children. Ear and Hearing. https://doi.org/10.1097/00003446-200004000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.