Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Partial volume effects in positron emission tomography (PET) lead to quantitative under- and over-estimations of the regional concentrations of radioactivity in reconstructed images and corresponding errors in derived functional or parametric images. The limited resolution of PET leads to “tissue-fraction” effects, reflecting underlying tissue heterogeneity, and “spillover” effects between regions. Addressing the former problem in general requires supplementary data, for example, coregistered high-resolution magnetic resonance images, whereas the latter effect can be corrected for with PET data alone if the point-spread function of the tomograph has been characterized. Analysis of otherwise homogeneous region-of-interest data ideally requires a combination of tissue classification and correction for the point-spread function. The formulation of appropriate algorithms for partial volume correction (PVC) is dependent on both the distribution of the signal and the distribution of the underlying noise. A mathematical framework has therefore been developed to accommodate both of these factors and to facilitate the development of new PVC algorithms based on the description of the problem. Several methodologies and algorithms have been proposed and implemented in the literature in order to address these problems. These methods do not, however, explicitly consider the noise model while differing in their underlying assumptions. The general theory for estimation of regional concentrations, associated error estimation, and inhomogeneity tests are presented in a weighted least squares framework. The analysis has been validated using both simulated and real PET data sets. The relations between the current algorithms and those published previously are formulated and compared. The incorporation of tensors into the formulation of the problem has led to the construction of computationally rapid algorithms taking into account both tissue-fraction and spillover effects. The suitability of their application to dynamic and static images is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
(2005) · Statistics for Biology and Health · doi:10.1007/0-387-27255-0_9 · Cited by 20,133
McCullagh, P., & Nelder, J. A. (1989) · doi:10.1007/978-1-4899-3242-6 · Cited by 16,836
Lohrli, A. (1985) · Notes and Queries · doi:10.1093/notesj/32.3.377-a · Cited by 4,352
Generalized Inverse of Matrices and Its Applications
Banerjee, K. S. (1973) · Technometrics · doi:10.1080/00401706.1973.10489026 · Cited by 2,310
Axelsson, O. (1994) · Cambridge University Press eBooks · doi:10.1017/cbo9780511624100 · Cited by 2,085
Nonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884 · cited 2×
“This was performed using linear and nonlinear transformations (Ashburner and Friston, 1999) with parameters derived from the MRI data set associated with the template (Hammers et al.”
MethodEnhancement of MR Images Using Registration for Signal Averaging
Holmes, C. J., Hoge, R., Collins, L., Woods, R., Toga, A. W., & Evans, A. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00032 · Cited by 1,417
Self-citationQuantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143 · cited 2×
“The second is the “point-spread effect,” or spillover between regions, again reflecting the limited resolution of the tomograph (Hoffman et al., 1979; Mazziotta et al., 1981; Leahy and Qi, 2000).”
BackgroundCorrection for partial volume effects in PET: principle and validation.
ROUSSET, O. G., Ma, Y., & Evans, A. C. (1998) · PubMed · Cited by 1,062
Self-citation
Cited by
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Latent feature representation with stacked auto-encoder for AD/MCI diagnosis
Initiative, T. A. D. N., Suk, H.-I., Lee, S.-W., & Shen, D. (2015) · Brain Structure and Function · doi:10.1007/s00429-013-0687-3 · Cited by 526
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Imaging dopamine receptors in humans with [11C]-(+)-PHNO: Dissection of D3 signal and anatomy
Tziortzi, A. C., Searle, G. E., Tzimopoulou, S., Salinas, C., Beaver, J. D., Jenkinson, M., Laruelle, M., Rabiner, E. A., & Gunn, R. N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.044 · Cited by 452
Self-citationEnsembles of Deep Learning Architectures for the Early Diagnosis of the Alzheimer’s Disease
Ortiz, A., Munilla, J., Górriz, J. M., & Ramírez, J. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500258 · Cited by 403
Daisne, J.-F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., & Grégoire, V. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00270-6 · Cited by 380
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Brain Serotonin and Dopamine Transporter Bindings in Adults With High-Functioning Autism
Nakamura, K., Sekine, Y., Ouchi, Y., Tsujii, M., Yoshikawa, E., Futatsubashi, M., Tsuchiya, K. J., Sugihara, G., Iwata, Y., Suzuki, K., et al. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2009.137 · Cited by 352
Thomas, B. A., Erlandsson, K., Modat, M., Thurfjell, L., Vandenberghe, R., Ourselin, S., & Hutton, B. F. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1745-9 · Cited by 316
Tziortzi, A. C., Haber, S. N., Searle, G. E., Tsoumpas, C., Long, C. J., Shotbolt, P., Douaud, G., Jbabdi, S., Behrens, T. E. J., Rabiner, E. A., et al. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhs397 · Cited by 315
Self-citationBoileau, I., Dagher, A., Leyton, M., Gunn, R. N., Baker, G. B., Diksic, M., & Benkelfat, C. (2006) · Archives of General Psychiatry · doi:10.1001/archpsyc.63.12.1386 · Cited by 305
Self-citationRegression algorithm correcting for partial volume effects in arterial spin labeling MRI
Asllani, I., Borogovac, A., & Brown, T. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21670 · Cited by 241
“M ri Pj ri mj ri [6]”
Boileau, I., Dagher, A., Leyton, M., Welfeld, K., Booij, L., Diksic, M., & Benkelfat, C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.4370-06.2007 · Cited by 222
“To minimize the regional point-spread and tissue-fraction effects resulting from the limited resolution of the PET camera, a partial volume effect correction was performed (Aston et al., 2002).”
MethodThomas, B. A., Cuplov, V., Bousse, A., Mendes, A., Thielemans, K., Hutton, B. F., & Erlandsson, K. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/22/7975 · Cited by 196
Partial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190
“tion with an SD of a few percent in both phantom and simulation studies [25,29,37,81].”
BackgroundMethodResultInfluentialTOORNVLIET, R., VANBERCKEL, B., LUURTSEMA, G., LUBBERINK, M., GELDOF, A., BOSCH, T., OERLEMANS, R., LAMMERTSMA, A., & FRANSSEN, E. (2006) · Clinical Pharmacology & Therapeutics · doi:10.1016/j.clpt.2006.02.004 · Cited by 188
Kagawa, K., Chugani, D. C., Asano, E., Juhász, C., Muzik, O., Shah, A., Shah, J., Sood, S., Kupsky, W. J., Mangner, T. J., et al. (2005) · Journal of Child Neurology · doi:10.1177/08830738050200050701 · Cited by 175
Barrett, S. P., Boileau, I., Okker, J., Pihl, R. O., & Dagher, A. (2004) · Synapse · doi:10.1002/syn.20066 · Cited by 173
“BP values were extracted from each ROI and corrected for partial volume effects using a method that takes into account the noise and resolution characteristics of the scanner (Aston et al., 2002).”
MethodZaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108
“As for the overall performance, in the absence of major sources of registration or segmentation errors, partial volume corrected estimates have been found to be typically within 5–10% of true tracer concentration with a standard deviation of a few percent in both phantom and simulation studies (Rousset et al., 1998; S…”
BackgroundPET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“misregistration and mis-segmentation) [75, 76].”
Lehnert, W., Gregoire, M.-C., Reilhac, A., & Meikle, S. R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.032 · Cited by 52
Amphetamine-induced dopamine release and neurocognitive function in treatment-naive adults with ADHD
Cherkasova, M. V., Faridi, N., Casey, K. F., O'Driscoll, G. A., Hechtman, L., Joober, R., Baker, G. B., Palmer, J., Dagher, A., Leyton, M., et al. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2013.349 · Cited by 49
Livingston, N. R., Calsolaro, V., Hinz, R., Nowell, J., Raza, S., Gentleman, S., Tyacke, R. J., Myers, J., Venkataraman, A. V., Perneczky, R., et al. (2022) · Molecular Psychiatry · doi:10.1038/s41380-021-01429-y · Cited by 44
“Partial Volume Correction (PVC) was not performed as PVC can increase noise within the data [28], leading to further signal leakage between regions and tissue classes which cannot be corrected for [29].”
BackgroundSelf-citation
Metadata
- Authors
- Aston, J. A. D., Cunningham, V. J., Asselin, M.-C., Hammers, A., Evans, A. C., & Gunn, R. N.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2002-08
- Volume
- 22
- Issue
- 8
- Pages
- 1019-1034
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2120892458
- Cited by
- 180
- References
- 37
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.