Spatiotemporal Quantification of Cerebral Blood Flow during Functional Activation in Rat Somatosensory Cortex using Laser-Speckle Flowmetry
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Laser-speckle flowmetry was used to characterize activation flow coupling after electrical somatosensory stimulation of forepaw and hindpaw in the rat. Quantification of functional activation was made with high transverse spatial (μm) and temporal (msec) resolution. Different activation levels and duration of stimulation were quantitatively investigated, and were in good agreement with previous laser-Doppler measurements. Interestingly, the magnitude but not the overall shape of the response was found to scale with stimulus amplitude and the distance from the activation centroid. The results provide new insights about the spatial characteristics of cerebral blood flow response to functional activation, and the method should lead to improved understanding of the coupling of neuronal activity and hemodynamics under normal and pathologic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 2×
“…(Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is…”
MethodProcessing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763 · cited 2×
“N)] (Bandettini et al., 1993).”
BackgroundFrackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242 · cited 2×
“Thus far numerous methods have been used to measure blood flow changes in brain during functional activation, including positron emission tomography (Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al.”
MethodIntrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214 · cited 2×
“Laser-speckle flowmetry has also been used to measure blood flow in near-surface tissues such as skin (Fujii et al., 1985; Ruth, 1994), retina (Tamaki et al., 1994), optic nerve (Yaoeda et al., 2000), and recently brain ( Bolay et al., 2002; Dunn et al., 2001).”
MethodKim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001 · cited 2×
“…tomography (Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but…”
MethodMeasurement of local cerebral blood flow with iodo [14C] antipyrine
Sakurada, O., Kennedy, C., Jehle, J., Brown, J. D., Carbin, G. L., & Sokoloff, L. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.1.h59 · Cited by 926 · cited 2×
“…photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is still Received September 8, 2003; final…”
MethodDynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826 · cited 4×
“Recently, Dunn and colleagues have found a high correlation between the two techniques under conditions of spreading depression and ischemia (Dunn et al., 2001).”
BackgroundMethodInfluentialInsulin effects on monovalent cation transport and Na-K-ATPase activity
Hougen, T. J., Hopkins, B. E., & Smith, T. W. (1978) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1978.234.3.c59 · Cited by 696
Briers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686 · cited 1×
“Laser-speckle flowmetry (Briers, 2001; Briers and Webster, 1996) offers high spatiotemporal resolution imaging of CBF, especially for small animal models, and it is closely related to the laser-Doppler technique (Briers, 1996).”
BackgroundLaser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686 · cited 5×
“Laser-speckle flowmetry (Briers, 2001; Briers and Webster, 1996) offers high spatiotemporal resolution imaging of CBF, especially for small animal models, and it is closely related to the laser-Doppler technique (Briers, 1996).”
BackgroundMethodInfluential
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationLaser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Cerebral blood flow during exercise: mechanisms of regulation
Ogoh, S., & Ainslie, P. N. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00573.2009 · Cited by 502
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Robust flow measurement with multi-exposure speckle imaging
Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K. (2008) · Optics Express · doi:10.1364/oe.16.001975 · Cited by 367
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Laser Speckle Contrast Imaging of Cerebral Blood Flow
Dunn, A. K. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0469-0 · Cited by 278
Anesthesia and the Quantitative Evaluation of Neurovascular Coupling
Masamoto, K., & Kanno, I. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.50 · Cited by 273
Laser Speckle Contrast Imaging: Theory, Instrumentation and Applications
Senarathna, J., Rege, A., Li, N., & Thakor, N. V. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243140 · Cited by 269
Roche‐Labarbe, N., Carp, S. A., Surova, A., Patel, M., Boas, D. A., Grant, P. E., & Franceschini, M. A. (2010) · Human Brain Mapping · doi:10.1002/hbm.20868 · Cited by 236
“Although measurements of relative changes in blood flow index have previously been reported, for example during functional measurements [Durduran et al., 2004b] or cancer therapy monitoring [Zhou et al., 2007], the present work is one of the first attempts to use DCS to obtain absolute blood flow…”
MethodInfluentialZhou, C., Yu, G., Furuya, D., Greenberg, J. H., Yodh, A. G., & Durduran, T. (2006) · Optics Express · doi:10.1364/oe.14.001125 · Cited by 232
Self-citationCan laser speckle flowmetry be made a quantitative tool?
Duncan, D. D., & Kirkpatrick, S. J. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.002088 · Cited by 219
Diffuse correlation spectroscopy for measurement of cerebral blood flow: future prospects
Buckley, E. M., Parthasarathy, A. B., Grant, P. E., Yodh, A. G., & Franceschini, M. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011009 · Cited by 216
Self-citationThe effect of different anesthetics on neurovascular coupling
Franceschini, M. A., Radhakrishnan, H., Thakur, K., Wu, W., Ruvinskaya, S., Carp, S., & Boas, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.060 · Cited by 173
“The instrument we used in our experiments is similar to the system developed by Dr. Arjun Yodh at the University of Pennsylvania (Durduran et al., 2004b) and tested in several animal (Cheung et al., 2001; Culver et al., 2003a; Durduran et al., 2004a; Zhou et al., 2009) and human experiments (Durduran et al., 2004b; Du…”
MethodInfluentialNoninvasive detection of functional brain activity with near-infrared diffusing-wave spectroscopy
Li, J., Dietsche, G., Iftime, D., Skipetrov, S. E., Maret, G., Elbert, T., Rockstroh, B., & Gisler, T. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2007987 · Cited by 166
“This technique has been used for the study of hemodynamic changes in exposed rat brains during cortical spreading depression(19,20) and somato-sensory activation.(21) On the other hand, measurements of the temporal autocor-”
MethodPain, F., L’Heureux, B., & Gurden, H. (2011) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0708-4 · Cited by 161
“Several groups have used the spatial [118–122] and temporal contrast [123] to map relative blood flow changes in the somatosensory cortex, but the technique has not yet been applied to the MOB.”
Method
Metadata
- Authors
- Durduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2004-05
- Volume
- 24
- Issue
- 5
- Pages
- 518-525
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2071994625
- Cited by
- 168
- References
- 32
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.