Spatiotemporal Quantification of Cerebral Blood Flow during Functional Activation in Rat Somatosensory Cortex using Laser-Speckle Flowmetry
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Laser-speckle flowmetry was used to characterize activation flow coupling after electrical somatosensory stimulation of forepaw and hindpaw in the rat. Quantification of functional activation was made with high transverse spatial (μm) and temporal (msec) resolution. Different activation levels and duration of stimulation were quantitatively investigated, and were in good agreement with previous laser-Doppler measurements. Interestingly, the magnitude but not the overall shape of the response was found to scale with stimulus amplitude and the distance from the activation centroid. The results provide new insights about the spatial characteristics of cerebral blood flow response to functional activation, and the method should lead to improved understanding of the coupling of neuronal activity and hemodynamics under normal and pathologic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 2×
“…(Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is…”
MethodProcessing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763 · cited 2×
“N)] (Bandettini et al., 1993).”
BackgroundFrackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242 · cited 2×
“Thus far numerous methods have been used to measure blood flow changes in brain during functional activation, including positron emission tomography (Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al.”
MethodIntrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214 · cited 2×
“Laser-speckle flowmetry has also been used to measure blood flow in near-surface tissues such as skin (Fujii et al., 1985; Ruth, 1994), retina (Tamaki et al., 1994), optic nerve (Yaoeda et al., 2000), and recently brain ( Bolay et al., 2002; Dunn et al., 2001).”
MethodKim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001 · cited 2×
“…tomography (Frackowiak et al., 1980), single photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but…”
MethodMeasurement of local cerebral blood flow with iodo [14C] antipyrine
Sakurada, O., Kennedy, C., Jehle, J., Brown, J. D., Carbin, G. L., & Sokoloff, L. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.1.h59 · Cited by 926 · cited 2×
“…photon emission computed tomography (Van Heertum and Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is still Received September 8, 2003; final…”
MethodDynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826 · cited 4×
“Recently, Dunn and colleagues have found a high correlation between the two techniques under conditions of spreading depression and ischemia (Dunn et al., 2001).”
BackgroundMethodInfluentialInsulin effects on monovalent cation transport and Na-K-ATPase activity
Hougen, T. J., Hopkins, B. E., & Smith, T. W. (1978) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1978.234.3.c59 · Cited by 696
Briers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686 · cited 1×
“Laser-speckle flowmetry (Briers, 2001; Briers and Webster, 1996) offers high spatiotemporal resolution imaging of CBF, especially for small animal models, and it is closely related to the laser-Doppler technique (Briers, 1996).”
BackgroundLaser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686 · cited 5×
“Laser-speckle flowmetry (Briers, 2001; Briers and Webster, 1996) offers high spatiotemporal resolution imaging of CBF, especially for small animal models, and it is closely related to the laser-Doppler technique (Briers, 1996).”
BackgroundMethodInfluentialBoas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606 · cited 1×
“A variety of methods (Briers, 2001) use this effect for tissue studies, including deep tissue laser-Doppler flowmetry (Bonner and Nossal, 1990) and diffuse correlation spectroscopy (Boas and Yodh, 1997; Cheung et al., 2001; Culver et al., 2003a).”
MethodSelf-citationMapping the body representation in the SI cortex of anesthetized and awake rats
Chapin, J. K., & Lin, C. (1984) · Journal of Comparative Neurology · doi:10.1002/cne.902290206 · Cited by 584 · cited 5×
“The AFC response was well localized and different functional representations of the forepaw and hindpaw were separated by 1.6 to 8 mm, in close agreement with previous results from electrophysiology wherein the areas were determined to be approximately 1.8 mm apart (Chapin and Lin, 1984).”
BackgroundResultInfluentialCoupling of brain activity and cerebral blood flow: basis of functional neuroimaging.
Villringer, A., & Dirnagl, U. (1995) · PubMed · Cited by 566
Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation
Mandeville, J. B., Marota, J. J. A., Kosofsky, B. E., Keltner, J. R., Weissleder, R., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390415 · Cited by 549 · cited 2×
“It is also qualitatively similar to other hemodynamic measurements, such as those of diffuse optical tomography (Culver et al., 2003b), functional magnetic resonance imaging (Duong et al., 2000; Hyder et al., 1994; Mandeville et al., 1998 ), and optical intrinsic signal imaging (Narayan et al., 1994).”
ResultCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420 · cited 4×
“It is also qualitatively similar to other hemodynamic measurements, such as those of diffuse optical tomography (Culver et al., 2003b), functional magnetic resonance imaging (Duong et al., 2000; Hyder et al., 1994; Mandeville et al., 1998), and optical intrinsic signal imaging (Narayan et al.,…”
BackgroundMethodResultInfluentialSelf-citationDunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Cheung, C., Culver, J. P., Takahashi, K., Greenberg, J. H., & Yodh, A. G. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/302 · Cited by 308 · cited 1×
“A variety of methods (Briers, 2001) use this effect for tissue studies, including deep tissue laser-Doppler flowmetry (Bonner and Nossal, 1990) and diffuse correlation spectroscopy (Boas and Yodh, 1997; Cheung et al., 2001; Culver et al., 2003a).”
MethodSelf-citationThe concept of coupling blood flow to brain function: Revision required?
Lou, H. C., Edvinsson, L., & MacKenzie, E. T. (1987) · Annals of Neurology · doi:10.1002/ana.410220302 · Cited by 301
Duong, T. Q., Silva, A. C., Lee, S.-P., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<383::aid-mrm10>3.0.co;2-q · Cited by 254 · cited 4×
“During functional activation, the AFC response may not extend to the topmost layers, with the maximal response occurring at layers III through IV (approximately 600 m below the cortical surface) (Chapin and Lin, 1984; Coq and Xerri, 1998; Duong et al., 2000 ).”
BackgroundResultInfluentialPhysical model for the spectroscopic analysis of cortical intrinsic optical signals
Kohl, M., Lindauer, U., Royl, G., Kühl, M., Gold, L., Villringer, A., & Dirnagl, U. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/317 · Cited by 176 · cited 2×
“This has been modeled by Monte-Carlo methods revealing that most of the information comes from the top approximately 300 m of the cortical tissue when the illuminating wavelength is 785 nm Kohl et al. (2000).”
MethodDynamic Magnetic Resonance Imaging of the Rat Brain during Forepaw Stimulation
Hyder, F., Behar, K. L., Martin, M. A., Blamire, A. M., & Shulman, R. G. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.81 · Cited by 156 · cited 1×
“…is also qualitatively similar to other hemodynamic measurements, such as those of diffuse optical tomography (Culver et al., 2003b), functional magnetic resonance imaging (Duong et al., 2000; Hyder et al., 1994; Mandeville et al., 1998), and optical intrinsic signal imaging (Narayan et al., 1994).”
ResultCoq, J., & Xerri, C. (1998) · Experimental Brain Research · doi:10.1007/s002210050452 · Cited by 136 · cited 4×
“During functional activation, the AFC response may not extend to the topmost layers, with the maximal response occurring at layers III through IV (approximately 600 m below the cortical surface) (Chapin and Lin, 1984; Coq and Xerri, 1998; Duong et al., 2000).”
BackgroundResultInfluentialAnces, B. M., Buerk, D. G., Greenberg, J. H., & Detre, J. A. (2001) · Neuroscience Letters · doi:10.1016/s0304-3940(01)01868-7 · Cited by 122 · cited 2×
“…-·-·-·-·-·-·-·-·-· ' Current (mA) 2 response (Ances et al., 1998, 1999), modeling the nonlinear effects (Ances et al., 2000), combining with changes in O2 to estimate CMRO2 (Ances et al., 2001a,c), and investigating the effect of carbon dioxide on the CBF response (Ances et al., 2001b).”
BackgroundSelf-citationAnces, B. M., Zarahn, E., Greenberg, J. H., & Detre, J. A. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200006000-00004 · Cited by 76
Self-citationAnces, B. M., Wilson, D. F., Greenberg, J. H., & Detre, J. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200105000-00005 · Cited by 72 · cited 1×
“…-·-·-·-·-·-·-·-·-· ' Current (mA) 2 response (Ances et al., 1998, 1999), modeling the nonlinear effects (Ances et al., 2000), combining with changes in O2 to estimate CMRO2 (Ances et al., 2001a,c), and investigating the effect of carbon dioxide on the CBF response (Ances et al., 2001b).”
BackgroundSelf-citationLaminar Analysis of Cerebral Blood Flow in Cortex of Rats by Laser-Doppler Flowmetry: A Pilot Study
Fabricius, M., Akgören, N., Dirnagl, U., & Lauritzen, M. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199712000-00008 · Cited by 71 · cited 2×
“Laser-Doppler flowmetry, with near-infrared source wavelengths, was shown to be highly sensitive to layer IV, but had lower sensitivity to shallower levels (Fabricius et al., 1997).”
BackgroundDetre, J. A., Ances, B. M., Takahashi, K., & Greenberg, J. H. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00322-9 · Cited by 71 · cited 7×
“However, the peak blood-flow response measured with speckle-contrast imaging is approximately 30% lower than that measured previously with laser-Doppler flowmetry (Detre et al., 1998).”
BackgroundMethodInfluentialSelf-citationLaser Doppler Imaging of Activation-Flow Coupling in the Rat Somatosensory Cortex
Ances, B. M., Greenberg, J. H., & Detre, J. A. (1999) · NeuroImage · doi:10.1006/nimg.1999.0510 · Cited by 67 · cited 4×
“…Tikofsky, 2000), magnetic resonance imaging (Kim, 1995; Kwong et al., 1992), autoradiography (Sakurada et al., 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is still Received September 8, 2003; final version received December 24, 2003; accepted January…”
BackgroundInfluentialSelf-citationYu, G., Durduran, T., Furuya, D., Greenberg, J. H., & Yodh, A. G. (2003) · Applied Optics · doi:10.1364/ao.42.002931 · Cited by 60 · cited 2×
“…be combined with other optical techniques including optical intrinsic imaging (Dunn et al., 2003), diffuse optical tomography (Culver et al., 2003b; Yu et al., 2003), and diffuse correlation tomography (Culver et al., 2003a) for simultaneous measurement of tissue oxygen saturation, total…”
BackgroundSelf-citationRuth, B. (1994) · Medical Engineering & Physics · doi:10.1016/1350-4533(94)90023-x · Cited by 53 · cited 2×
“Laser-speckle flowmetry has also been used to measure blood flow in near-surface tissues such as skin (Fujii et al., 1985; Ruth, 1994), retina (Tamaki et al.”
MethodScanning Laser-Doppler Flowmetry of Rat Cerebral Circulation during Cortical Spreading Depression
Nielsen, A. N., Fabricius, M. E., & Lauritzen, M. (2000) · Journal of Vascular Research · doi:10.1159/000054084 · Cited by 49 · cited 2×
“, 1978), and laser-Doppler flowmetry (Ances et al., 1999; Nielsen et al., 2000), but there is still a need for relatively simple and inexpensive techniques”
BackgroundAnces, B. M., Greenberg, J. H., & Detre, J. A. (2001) · Brain Research · doi:10.1016/s0006-8993(01)02721-4 · Cited by 32 · cited 1×
“…-·-·-·-·-·-·-·-·-· ' Current (mA) 2 response (Ances et al., 1998, 1999), modeling the nonlinear effects (Ances et al., 2000), combining with changes in O2 to estimate CMRO2 (Ances et al., 2001a,c), and investigating the effect of carbon dioxide on the CBF response (Ances et al., 2001b).”
BackgroundSelf-citation
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationLaser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Cerebral blood flow during exercise: mechanisms of regulation
Ogoh, S., & Ainslie, P. N. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00573.2009 · Cited by 502
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Metadata
- Authors
- Durduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2004-05
- Volume
- 24
- Issue
- 5
- Pages
- 518-525
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2071994625
- Cited by
- 168
- References
- 32
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.