MEG and EEG in Epilepsy
The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Abstract
Both EEG and magnetoencephalogram (MEG), with a time resolution of 1 ms or less, provide unique neurophysiologic data not obtainable by other neuroimaging techniques. MEG has now emerged as a mature clinical technology. While both EEG and MEG can be performed with more than 100 channels, MEG recordings with 100 to 300 channels are more easily done because of the time needed to apply a large number of EEG electrodes. EEG has the advantage of the long-term video EEG recordings, which facilitates extensive temporal sampling across all periods of the sleep/wake cycle. MEG and EEG seem to complement each other for the detection of interictal epileptiform discharges, because some spikes can be recorded only on MEG but not on EEG and vice versa. Most studies indicate that MEG seems to be more sensitive for neocortical spike sources. Both EEG and MEG source localizations show excellent agreement with invasive electrical recordings, clarify the spatial relationship between the irritative zone and structural lesions, and finally, attribute epileptic activity to lobar subcompartments in temporal lobe and to a lesser extent in extratemporal epilepsies. In temporal lobe epilepsy, EEG and MEG can differentiate between patients with mesial, lateral, and diffuse seizure onsets. MEG selectively detects tangential sources. EEG measures both radial and tangential activity, although the radial components dominate the EEG signals at the scalp. Thus, while EEG provides more comprehensive information, it is more complicated to model due to considerable influences of the shape and conductivity of the volume conductor. Dipole localization techniques favor MEG due to the higher accuracy of MEG source localization compared to EEG when using the standard spherical head shape model. However, if special care is taken to address the above issues and enhance the EEG, the localization accuracy of EEG and MEG actually are comparable, although these surface EEG analytic techniques are not typically approved for clinical use in the United States. MEG dipole analysis is approved for clinical use and thus gives information that otherwise usually requires invasive intracranial EEG monitoring. There are only a few dozen whole head MEG units in operation in the world. While EEG is available in every hospital, specialized EEG laboratories capable of source localization techniques are nearly as scarce as MEG facilities. The combined use of whole-head MEG systems and multichannel EEG in conjunction with advanced source modeling techniques is an area of active development and will allow a better noninvasive characterization of the irritative zone in presurgical epilepsy evaluation. Finally, additional information on epilepsy may be gathered by either MEG or EEG analysis of data beyond the usual bandwidths used in clinical practice, namely by analysis of activity at high frequencies and near-DC activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“However, Hämäläinen et al. (1993) pointed out that the current dipoles from the implanted depth electrodes in the study of Cohen et al. (1990) were nearly radial, decreasing the signal-to-noise ratio of MEG.”
BackgroundBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Llinás, R. R., Ribary, U., Jeanmonod, D., Kronberg, E., & Mitra, P. P. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.26.15222 · Cited by 1,388 · cited 2×
“…from MEG and primarily intracranial EEG recordings that higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba…”
BackgroundA standardized boundary element method volume conductor model
Fuchs, M., Kastner, J., Wagner, M., Hawes, S., & Ebersole, J. S. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00030-5 · Cited by 999 · cited 3×
“EEG source localizations can be considerably improved by the use of realistic head shape and brain models, which are especially relevant for epileptic activity arising from the temporal lobes (Ebersole et al., 1996; Fuchs et al., 1998a; Fuchs et al., 2001; Fuchs et al., 2002; Roth et al., 1993; Roth et al., 1997).”
BackgroundMethodCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 1×
“Magnetoencephalographic (MEG) recordings were first made by David Cohen (Cohen, 1968, 1972).”
MethodStaba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666 · cited 1×
“…higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba et al., 2002; Timofeev et al., 1992; Wendling et al., 2003).”
BackgroundCooper, R., Winter, A. L., Crow, H. J., & Walter, W. G. (1965) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(65)90088-x · Cited by 561 · cited 2×
“…to 4 cm2 of synchronized epileptic activity involving the lateral neocortex was necessary to produce a detectable MEG signal at the scalp (Baumgartner et al., 1992; Mikuni et al., 1997; Oishi et al., 2002), which is smaller than the classical 6 cm2 proposed for the scalp-EEG (Cooper et al., 1965).”
BackgroundLinear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436 · cited 5×
“Thus, distributed source models could add additional information on the spatial distribution of the irritative zone (Fuchs et al., 1999; Michel et al., 1999).”
BackgroundInfluentialEffectiveness of Multiple EEGs in Supporting the Diagnosis of Epilepsy: An Operational Curve
Salinsky, M., Kanter, R., & Dasheiff, R. M. (1987) · Epilepsia · doi:10.1111/j.1528-1157.1987.tb03652.x · Cited by 416 · cited 1×
“When interictal epileptiform activity is present, it can be identified in the first EEG in 50%, in 84% by the third EEG, and in 92% by the fourth (Salinsky et al., 1987).”
BackgroundEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413 · cited 4×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
BackgroundInfluentialA study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383 · cited 3×
“Phantom studies reported localization accuracies of 7 to 8 mm for the EEG and of 2 to 4 mm for the MEG (Gharib et al., 1995; Leahy et al., 1998; Yamamoto et al., 1988).”
BackgroundMethodMonte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349 · cited 3×
“…the greater depth and orientation sensitivity of the EEG. Combining EEG and MEG produced the best accuracy for the same number of total sensors, and the most significant gains in localization could be achieved by combining a small number of EEG and a large number of MEG channels (Liu et al., 2002).”
BackgroundInfluentialStam, C. J., van Cappellen van Walsum, A. M., Pijnenburg, Y. A. L., Berendse, H. W., de Munck, J. C., Scheltens, P., & van Dijk, B. W. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200212000-00010 · Cited by 303 · cited 2×
“…intracranial EEG recordings that higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba et al., 2002;…”
BackgroundDemonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300 · cited 1×
“(6) In contrast to EEG, MEG is reference-free (Barth et al., 1986a; Cohen and Cuffin, 1983).”
BackgroundAn improved boundary element method for realistic volume-conductor modeling
Fuchs, M., Drenckhahn, R., Wischmann, H., & Wagner, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704867 · Cited by 299 · cited 4×
“Some authors concluded that both techniques were complementary, and the combination of both techniques yielded information not available from either technique alone (Baillet et al., 1999; Baillet et al., 2002; Fuchs et al., 1998b).”
BackgroundMethodInfluentialLocalization of Temporal Lobe Foci by Ictal EEG Patterns
Ebersole, J. S., & Pacia, S. V. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb00577.x · Cited by 278
Epileptic fast intracerebral EEG activity: evidence for spatial decorrelation at seizure onset
Wendling, F., Bartolomei, F., Bellanger, J. J., Bourien, J., & Chauvel, P. (2003) · Brain · doi:10.1093/brain/awg144 · Cited by 273 · cited 1×
“…higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba et al., 2002; Timofeev et al., 1992; Wendling et al., 2003).”
BackgroundFunctional imaging and localization of electromagnetic brain activity
Scherg, M. (1992) · Brain Topography · doi:10.1007/bf01129037 · Cited by 253 · cited 1×
“Thus, dipoles should be viewed as useful mathematical abstractions rather than as real neuronal elements (Romani and Rossini, 1988; Scherg, 1992; Scherg and Ebersole, 1993).”
BackgroundMagnetoencephalographic fields from patients with spontaneous and induced migraine aura
Bowyer, S. M., Aurora, S. K., Moran, J. E., Tepley, N., & Welch, K. M. A. (2001) · Annals of Neurology · doi:10.1002/ana.1293 · Cited by 251 · cited 1×
“In humans, DC-MEG has been used to demonstrate similar findings in migraine (Barkley et al., 1990, Bowyer et al., 2001), familial hemiplegic migraine (Gutschalk et al., 2002), and slow shifts produced by evoked responses in normal subjects (Mackert et al., 1999, 2001).”
Improving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239 · cited 4×
“Some authors concluded that both techniques were complementary, and the combination of both techniques yielded information not available from either technique alone (Baillet et al., 1999; Baillet et al., 2002; Fuchs et al., 1998b).”
BackgroundMethodInfluentialNeuromagnetic Localization of Epileptiform Spike Activity in the Human Brain
Barth, D. S., Sutherling, W., Engel, J., & Beatty, J. (1982) · Science · doi:10.1126/science.6813968 · Cited by 229
Model Studies of the Magnetocardiogram
Grynszpan, F., & Geselowitz, D. B. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86034-5 · Cited by 226 · cited 1×
“The ECD is not a physical point, but it represents the activity of a small collection of synchronously firing neurons (Grynszpan and Geselowitz, 1973).”
BackgroundMagnetic localization of neuronal activity in the human brain.
Yamamoto, T., Williamson, S. J., Kaufman, L., Nicholson, C., & Llinás, R. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.22.8732 · Cited by 205 · cited 1×
“Phantom studies reported localization accuracies of 7 to 8 mm for the EEG and of 2 to 4 mm for the MEG (Gharib et al., 1995; Leahy et al., 1998; Yamamoto et al., 1988).”
BackgroundBarth, D. S., Sutherling, W., Engle, J., & Beatty, J. (1984) · Science · doi:10.1126/science.6422552 · Cited by 199 · cited 1×
“…close proximity to various structural lesions, which helped to better define the spatial relationship between these lesions and the irritative zone (Barth et al., 1984a; Baumgartner et al., 2000b; Knowlton et al., 1997; Morioka et al., 1999; Morioka et al., 2000; Ricci et al., 1985; Stefan et al.,…”
BackgroundA Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., et al. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00800.x · Cited by 193 · cited 3×
“…have addressed the question of the diagnostic yield of MEG, because most commonly only those patients who actually exhibited spikes on MEG were presented (Lamusuo et al., 1999) or only patients with frequent interictal spikes on scalp-EEG were referred for MEG recordings (Wheless et al., 1999).”
BackgroundMikuni, N., Nagamine, T., Ikeda, A., Terada, K., Taki, W., Kimura, J., Kikuchi, H., & Shibasaki, H. (1997) · NeuroImage · doi:10.1006/nimg.1997.0272 · Cited by 190 · cited 3×
“…the detection sensitivity of EEG and MEG include the geometry and orientation of the sources, the amplitude of the signal, the degree of vertical, intracortical synchronization, and finally, technical aspects, such as the design of the sensors (Baumgartner et al., 1992; Mikuni et al., 1997).”
BackgroundResultCascino, G. D., Trenerry, M. R., So, E. L., Sharbrough, F. W., Shin, C., Lagerlund, T. D., Zupanc, M. L., & Jack, C. R. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb00629.x · Cited by 177 · cited 1×
“In one study, the diagnostic yield of routine-EEG was 77.4%, while long-term EEG monitoring revealed interictal epileptiform discharges in an additional 15.1% of patients (Cascino et al., 1996).”
BackgroundInfluentialBoundary element method volume conductor models for EEG source reconstruction
Fuchs, M., Wagner, M., & Kastner, J. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00589-2 · Cited by 165 · cited 3×
“EEG source localizations can be considerably improved by the use of realistic head shape and brain models, which are especially relevant for epileptic activity arising from the temporal lobes (Ebersole et al., 1996; Fuchs et al., 1998a; Fuchs et al., 2001; Fuchs et al., 2002; Roth et al., 1993; Roth et al., 1997).”
BackgroundMethodKissler, J. M., Müller, M. M., Fehr, T., Rockstroh, B. S., & Elbert, T. R. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00425-9 · Cited by 164 · cited 1×
“…however, it is known from MEG and primarily intracranial EEG recordings that higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999;…”
BackgroundMEG Predicts Epileptic Zone in Lesional Extrahippocampal Epilepsy: 12 Pediatric Surgery Cases
Otsubo, H., Ochi, A., Elliott, I., Chuang, S. H., Rutka, J. T., Jay, V., Aung, M., Sobel, D. F., & Snead, O. C. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.16701.x · Cited by 161 · cited 2×
“Finally, resection of the MEG-defined irritative spike zone had prognostic implications on postoperative seizure control (Otsubo et al., 2001).”
BackgroundMethodEpileptic Spikes: Magnetoencephalography versus Simultaneous Electrocorticography
Oishi, M., Otsubo, H., Kameyama, S., Morota, N., Masuda, H., Kitayama, M., & Tanaka, R. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.10702.x · Cited by 158 · cited 2×
“…to 4 cm2 of synchronized epileptic activity involving the lateral neocortex was necessary to produce a detectable MEG signal at the scalp (Baumgartner et al., 1992; Mikuni et al., 1997; Oishi et al., 2002), which is smaller than the classical 6 cm2 proposed for the scalp-EEG (Cooper et al., 1965).”
BackgroundTimofeev, I., Grenier, F., & Steriade, M. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.3.1495 · Cited by 153
How well does a three-sphere model predict positions of dipoles in a realistically shaped head?
Roth, B. J., Balish, M., Gorbach, A. M., & Sato, S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90017-p · Cited by 152 · cited 2×
“The localization could be considerably improved by the application of realistically shaped brain and head models as mentioned above (Ebersole et al., 1996; Fuchs et al., 1998a; Fuchs et al., 2001; Fuchs et al., 2002; Roth et al., 1993; Roth et al., 1997).”
BackgroundMethodStefan, H., Schneider, S., Feistel, H., Pawlik, G., Schüler, P., Abraham‐Fuchs, K., Schlegel, T., Neubauer, U., & Huk, W. J. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb02195.x · Cited by 149 · cited 2×
“…EEG recordings (Ebersole, 1999; Ko et al., 1998; Knowlton et al., 1997; Minassian et al., 1999; Morioka et al., 2000; Nakasoto et al., 1994; Otsubo et al., 1999; Paetau et al., 1994; Rose et al., 1987; Smith et al., 1995b; Stefan et al., 1992; Sutherling et al., 1987; Sutherling et al., 1988a).”
BackgroundLantz, G., Michel, C. M., Pascual-Marqui, R. D., Spinelli, L., Seeck, M., Seri, S., Landis, T., & Rosén, I. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(96)96551-0 · Cited by 148 · cited 2×
“Recently distributed inverse solutions, which estimate three-dimensional current density distributions rather than dipolar sources, were applied to interictal EEG data (Fuchs et al., 1999; Lantz et al., 1997; Lantz et al., 2001; Michel et al., 1999).”
BackgroundReliability of dipole models of epileptic spikes
Merlet, I., & Gotman, J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00062-5 · Cited by 143 · cited 7×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
BackgroundMethodResultInfluentialSpike voltage topography identifies two types of frontotemporal epileptic foci
Ebersole, J. S., & Wade, P. B. (1991) · Neurology · doi:10.1212/wnl.41.9.1425 · Cited by 142 · cited 1×
“Ebersole and Wade (1991) were the first to differentiate spikes based on their voltage topography.”
BackgroundScherg, M., & Ebersole, J. S. (1993) · Brain Topography · doi:10.1007/bf01128700 · Cited by 135 · cited 3×
“While source modeling techniques can equally be applied to the scalp-EEG as well (Scherg and Ebersole, 1993), EEG software of this type is typically sold as a research tool and, in the United States, does not carry Food and Drug Administration approval for source analysis of clinical data in…”
BackgroundMethodMagnetic localization of a dipolar current source implanted in a sphere and a human cranium
Barth, D. S., Sutherling, W. W., Broffman, J., & Beatty, J. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90094-5 · Cited by 134 · cited 1×
“(6) In contrast to EEG, MEG is reference-free (Barth et al., 1986a; Cohen and Cuffin, 1983).”
BackgroundEEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132 · cited 2×
“…in a large number of studies (Baumgartner et al., 1995; Baumgartner et al., 1996; Boon et al., 1997a; Boon et al., 1997b; Boon and D’Have, 1995; Ebersole, 1991, 1994; Ebersole, 2000; Ebersole et al., 1996; Huppertz et al., 2001; Merlet et al., 1996; Merlet et al., 1998; Merlet and Gotman,…”
BackgroundSmith, M. L., Elliott, I., & Lach, L. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.26101.x · Cited by 124 · cited 1×
“The utility of MEG in three patients with localization-related epilepsy arising from the operculum and no lesions on MRI has also been reported (Elisevich and Smith, 2002; Smith et al., 2002).”
BackgroundThe magnetic field of complex partial seizures agrees with intracranial localizations
Sutherling, W. W., Crandall, P. H., Engel, J., Darcey, T. M., Cahan, L. D., & Barth, D. S. (1987) · Annals of Neurology · doi:10.1002/ana.410210605 · Cited by 119 · cited 2×
“Furthermore, MEG dipole localizations showed good agreement with the results obtained from invasive EEG recordings (Ebersole, 1999; Ko et al., 1998; Knowlton et al., 1997; Minassian et al., 1999; Morioka et al., 2000; Nakasoto et al., 1994; Otsubo et al., 1999; Paetau et al., 1994; Rose et al., 1987; Smith et al., 199…”
BackgroundResultSpatiotemporal EEG Analysis and Distributed Source Estimation in Presurgical Epilepsy Evaluation
Michel, C. M., de Peralta, R. G., Lantz, G., Andino, S. G., Spinelli, L., Blanke, O., Landis, T., & Seeck, M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00005 · Cited by 118 · cited 4×
“Recently distributed inverse solutions, which estimate three-dimensional current density distributions rather than dipolar sources, were applied to interictal EEG data (Fuchs et al., 1999; Lantz et al., 1997; Lantz et al., 2001; Michel et al., 1999).”
BackgroundInfluentialCombined EEG and MEG recordings of visual 40 Hz responses to illusory triangles in human
Tallon-Baudry, C., Bertrand, O., Wienbruch, C., Ross, B., & Pantev, C. (1997) · NeuroReport · doi:10.1097/00001756-199703240-00008 · Cited by 116 · cited 2×
“These frequencies are rarely analyzed in clinical practice; however, it is known from MEG and primarily intracranial EEG recordings that higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al.”
BackgroundPresurgical localization of functional cortex using magnetic source imaging
Gallen, C. C., Schwartz, B. J., Bucholz, R. D., Malik, G. M., Barkley, G. L., Smith, J. A. J., Tung, H., Copeland, B. R., Bruno, L. A., Assam, S., et al. (1995) · Journal of neurosurgery · doi:10.3171/jns.1995.82.6.0988 · Cited by 115 · cited 2×
“The single equivalent dipole model is well suited for mapping the localization of short latency evoked responses and can easily and noninvasively be used to identify eloquent cortex such as the visual, somatosensory, or auditory cortex (Gallen et al., 1995).”
BackgroundSelf-citationSutherling, W. W., & Barth, D. S. (1989) · Annals of Neurology · doi:10.1002/ana.410250409 · Cited by 114 · cited 2×
“…suggested that it is possible to record deep sources on scalp-EEG (Smith et al., 1985) and spikes arising from the mesiobasal temporal lobe on MEG (Sutherling and Barth, 1989; Stefan et al., 1992), others could not record spikes restricted to mesial temporal structures on scalp-EEG (Fernandez…”
BackgroundCombined MEG and EEG source imaging by minimization of mutual information
Baillet, S., Garnero, L., Marin, G., & Hugonin, J.-P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759053 · Cited by 113 · cited 1×
“Some authors concluded that both techniques were complementary, and the combination of both techniques yielded information not available from either technique alone (Baillet et al., 1999; Baillet et al., 2002; Fuchs et al., 1998b).”
BackgroundPropagation of interictal epileptic activity in temporal lobe epilepsy
Baumgartner, C., Lindinger, G., Ebner, A.-S., Aull, S., Serles, W., Olbrich, A., Lurger, S., Czech, T., Burgess, R. C., & Luders, H. O. (1995) · Neurology · doi:10.1212/wnl.45.1.118 · Cited by 110 · cited 3×
“Other laboratories subsequently confirmed these findings (Baumgartner et al., 1995; Boon et al., 1997a; Boon and D’Have, 1995; Lantz et al., 1996; Merlet et al., 1996).”
BackgroundResultSelf-citationIctal magnetic source imaging as a localizing tool in partial epilepsy
Eliashiv, D. S., Elsas, S., Squires, K. C., Fried, I., & Engel, J. (2002) · Neurology · doi:10.1212/01.wnl.0000032493.83875.0b · Cited by 105 · cited 1×
“While most reports of ictal MEG are of isolated seizures, Eliashiv et al. (2002) made a systematic attempt to record seizures in a group of patients with neocortical epilepsy undergoing evaluation for epilepsy surgery.”
BackgroundNoninvasive Localization of Epileptogenic Foci by EEG Source Modeling
Ebersole, J. S. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01531.x · Cited by 104 · cited 1×
“…in a large number of studies (Baumgartner et al., 1995; Baumgartner et al., 1996; Boon et al., 1997a; Boon et al., 1997b; Boon and D’Have, 1995; Ebersole, 1991, 1994; Ebersole, 2000; Ebersole et al., 1996; Huppertz et al., 2001; Merlet et al., 1996; Merlet et al., 1998; Merlet and Gotman, 1999).”
BackgroundMerlet, I., García-Larrea, L., Grégoire, M., Lavenne, F., & Mauguìere, F. (1996) · Brain · doi:10.1093/brain/119.2.377 · Cited by 100 · cited 4×
“…in a large number of studies (Baumgartner et al., 1995; Baumgartner et al., 1996; Boon et al., 1997a; Boon et al., 1997b; Boon and D’Have, 1995; Ebersole, 1991, 1994; Ebersole, 2000; Ebersole et al., 1996; Huppertz et al., 2001; Merlet et al., 1996; Merlet et al., 1998; Merlet and Gotman, 1999).”
BackgroundResultInfluentialContinuous Source Imaging of Scalp Ictal Rhythms in Temporal Lobe Epilepsy
Assaf, B. A., & Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01201.x · Cited by 85
Accuracy of EEG dipole source localization using implanted sources in the human brain
Krings, T., Chiappa, K. H., Cuffin, B. N., Cochius, J. I., Connolly, S., & Cosgrove, G. R. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00106-0 · Cited by 82 · cited 1×
“EEG localization accuracy was improved from 17 mm with 21 EEG channels to 13 mm when 41 EEG channels were used (Krings et al., 1999).”
MethodLocalization of magnetic interictal discharges in temporal lobe epilepsy
Rose, D. F., Sato, S., Smith, P. D., Porter, R. J., Theodore, W. H., Friauf, W. S., Bonner, R. F., & Jabbari, B. (1987) · Annals of Neurology · doi:10.1002/ana.410220311 · Cited by 81 · cited 1×
“…EEG recordings (Ebersole, 1999; Ko et al., 1998; Knowlton et al., 1997; Minassian et al., 1999; Morioka et al., 2000; Nakasoto et al., 1994; Otsubo et al., 1999; Paetau et al., 1994; Rose et al., 1987; Smith et al., 1995b; Stefan et al., 1992; Sutherling et al., 1987; Sutherling et al., 1988a).”
BackgroundDipole localization in patients with epilepsy using the relistically shaped head model
Roth, B. J., Ko, D., von Albertini-Carletti, I., Scaffidi, D., & Sato, S. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95111-5 · Cited by 80 · cited 2×
“The localization could be considerably improved by the application of realistically shaped brain and head models as mentioned above (Ebersole et al., 1996; Fuchs et al., 1998a; Fuchs et al., 2001; Fuchs et al., 2002; Roth et al., 1993; Roth et al., 1997).”
BackgroundMethodMagnetoencephalography in presurgical epilepsy evaluation
Pataraia, E., Baumgartner, C., Lindinger, G., & Deecke, L. (2002) · Neurosurgical Review · doi:10.1007/s10143-001-0197-2 · Cited by 80 · cited 2×
“Both EEG and MEG today can be performed with more than 100 channels providing adequate spatial sampling (Lantz et al., 2003; Pataraia et al., 2002; ).”
BackgroundSelf-citationMagnetoencephalographic localization of epileptic cortex—impact on surgical treatment
Paetau, R., Kajola, M., Karhu, J., Nousiainen, U., Partanen, J. V., Tiihonen, J., Vapalahti, M. P., & Hari, R. (1992) · Annals of Neurology · doi:10.1002/ana.410320119 · Cited by 78 · cited 1×
“…recordings (Ebersole et al., 1995; Knowlton et al., 1997; Minassian et al., 1999; Nakasoto et al., 1994; Otsubo et al., 1999; Otsubo et al., 2001; Paetau et al., 1992; Paetau et al., 1994; Shiraishi et al., 2001; Smith et al., 1994; Smith et al., 1995a; Smith et al., 2000; Stefan et al., 2000;…”
BackgroundDipole Modeling in Epilepsy Surgery Candidates
Boon, P., D’Havé, M., Adam, C., Vonck, K. E. J., Baulac, M., Vandekerckhove, T., & Reuck, J. D. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01099.x · Cited by 78 · cited 6×
“Other laboratories subsequently confirmed these findings (Baumgartner et al., 1995; Boon et al., 1997a; Boon and D’Have, 1995; Lantz et al., 1996; Merlet et al., 1996).”
BackgroundMethodResultInfluentialMagnetoencephalography in Extratemporal Epilepsy
Stefan, H., Hummel, C., Hopfengärtner, R., Pauli, E., Tilz, C., Ganslandt, O., Kober, H., Möller, M., & Buchfelder, M. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200003000-00008 · Cited by 74 · cited 4×
“…structural lesions, which helped to better define the spatial relationship between these lesions and the irritative zone (Barth et al., 1984a; Baumgartner et al., 2000b; Knowlton et al., 1997; Morioka et al., 1999; Morioka et al., 2000; Ricci et al., 1985; Stefan et al., 1990; Stefan et al., 2000).”
BackgroundInfluentialInterictal and Ictal Magnetoencephalographic Study in Patients with Medial Frontal Lobe Epilepsy
Shiraishi, H., Watanabe, Y., Watanabe, M., Inoue, Y., Fujiwara, T., & Yagi, K. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.042007875.x · Cited by 73 · cited 1×
“…et al., 1995; Knowlton et al., 1997; Minassian et al., 1999; Nakasoto et al., 1994; Otsubo et al., 1999; Otsubo et al., 2001; Paetau et al., 1992; Paetau et al., 1994; Shiraishi et al., 2001; Smith et al., 1994; Smith et al., 1995a; Smith et al., 2000; Stefan et al., 2000; Wheless et al., 1999).”
Lantz, G., Menéndez, R. G. D. P., Andino, S. L. G., & Michel, C. M. (2001) · Brain Topography · doi:10.1023/a:1012996930489 · Cited by 72 · cited 3×
“Recently distributed inverse solutions, which estimate three-dimensional current density distributions rather than dipolar sources, were applied to interictal EEG data (Fuchs et al., 1999; Lantz et al., 1997; Lantz et al., 2001; Michel et al., 1999).”
BackgroundTopographical reliability of mesio-temporal sources of interictal spikes in temporal lobe epilepsy
Merlet, I., Garcı́a-Larrea, L., Ryvlin, P., Isnard, J., Sindou, M., & Mauguı̀ere, F. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00055-8 · Cited by 72 · cited 4×
“Similar to the results obtained for the MEG, EEG dipole sources could be localized adjacent to structural lesions (Huppertz et al., 2001) and corresponded well with invasive EEG recordings (Kobayashi et al., 2001; Lantz et al., 1996; Merlet et al., 1998; Merlet and Gotman, 1999).”
BackgroundResultInfluentialBenefit of Simultaneous Recording of EEG and MEG in Dipole Localization
Yoshinaga, H., Nakahori, T., Ohtsuka, Y., Oka, E., Kitamura, Y., Kiriyama, H., Kinugasa, K., Miyamoto, K., & Hoshida, T. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.42901.x · Cited by 65 · cited 13×
“Because magnetic fields are less distorted than electrical fields by the resistive properties of the skull and scalp, localization accuracy has been considered as one of the major advantages of MEG compared to scalpEEG.”
BackgroundInfluentialOtsubo, H., Sharma, R., Elliott, I., Holowka, S. A., Rutka, J. T., & Snead, O. C. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb05563.x · Cited by 64 · cited 2×
“…EEG recordings (Ebersole, 1999; Ko et al., 1998; Knowlton et al., 1997; Minassian et al., 1999; Morioka et al., 2000; Nakasoto et al., 1994; Otsubo et al., 1999; Paetau et al., 1994; Rose et al., 1987; Smith et al., 1995b; Stefan et al., 1992; Sutherling et al., 1987; Sutherling et al.,…”
BackgroundKirchberger, K., Hummel, C., & Stefan, H. (1998) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1998.tb07370.x · Cited by 61 · cited 1×
“…longer and/or multiple MEG measurements, Some authors successfully provoked epileptiform activity during MEG recordings by the application of proconvulsant drugs such as methohexital or clonidine (Brockhaus et al., 1997; Kirchberger et al., 1998a; Kirchberger et al., 1998b; Wienbruch et al., 1995).”
BackgroundZijlmans, M., Huiskamp, G. J. M., Leijten, F. S. S., der Meij, W. V., Wieneke, G. H., & van Huffelen, A. C. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200206000-00001 · Cited by 60 · cited 2×
“In addition, different aspects of a complex source can be revealed (Zijlmans et al., 2002).”
BackgroundMagnetoencephalography in Focal Epilepsy
Baumgartner, C., Pataraia, E., Lindinger, G., & Deecke, L. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01533.x · Cited by 59 · cited 7×
“Thus, the diagnostic yield was 92% for neocortical epilepsy versus 50% for mesial temporal lobe epilepsy in one study (Knowlton et al., 1997) and 73.3% for neocortical versus 42.3% for mesial temporal lobe epilepsy in another (Baumgartner et al., 2000b).”
BackgroundMethodInfluentialSelf-citationBowyer, S. M., Okada, Y. C., Papuashvili, N., Moran, J. E., Barkley, G. L., Welch, K. M. A., & Tepley, N. (1999) · Brain Research · doi:10.1016/s0006-8993(99)01892-2 · Cited by 57 · cited 1×
“In animals, DC-MEG has been used to demonstrate spreading cortical depression (Bowyer et al., 1999; Gardner-Medwin et al., 1991) as well as anoxic depolarization (Takanashi et al., 1991).”
MethodSelf-citationDipole‐Source Analysis in a Realistic Head Model in Patients with Focal Epilepsy
Herrendorf, G., Steinhoff, B. J., Kolle, R., Baudewig, J., Waberski, T. D., Buchner, H., & Paulus, W. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01508.x · Cited by 54 · cited 1×
“These latter models, however, provide more accurate solutions and can especially improve the accuracy of the solution for the EEG inverse problem in the temporal region (Fuchs et al., 1999; Hämäläinen and Sarvas, 1989; Herrendorf et al., 2000; Waberski et al., 1998, 2000).”
Background[18F]FDG‐PET and Whole‐Scalp MEG Localization of Epileptogenic Cortex
Lamusuo, S., Forss, N., Ruottinen, H., Bergman, J., Mäkelä, J. P., Mervaala, E., Solin, O. H., Rinne, J. K., Ruotsalainen, U., Ylinen, A., et al. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00799.x · Cited by 54 · cited 1×
“…have addressed the question of the diagnostic yield of MEG, because most commonly only those patients who actually exhibited spikes on MEG were presented (Lamusuo et al., 1999) or only patients with frequent interictal spikes on scalp-EEG were referred for MEG recordings (Wheless et al., 1999).”
BackgroundWaberski, T. D., Buchner, H., Lehnertz, K., Hufnagel, A., Fuchs, M., Beckmann, R., & Rienäcker, A. (1998) · Brain Topography · doi:10.1023/a:1022275024069 · Cited by 52 · cited 1×
“These latter models, however, provide more accurate solutions and can especially improve the accuracy of the solution for the EEG inverse problem in the temporal region (Fuchs et al., 1999; Hämäläinen and Sarvas, 1989; Herrendorf et al., 2000; Waberski et al., 1998, 2000).”
BackgroundNeuromagnetic functional localization: principles, state of the art, and perspectives
Romani, G. L., & Rossini, P. (1988) · Brain Topography · doi:10.1007/bf01129335 · Cited by 51 · cited 1×
“Thus, dipoles should be viewed as useful mathematical abstractions rather than as real neuronal elements (Romani and Rossini, 1988; Scherg, 1992; Scherg and Ebersole, 1993).”
BackgroundLocalization of epileptic foci using a large‐area magnetometer and functional brain anatomy
Tiihonen, J., Hari, R., Kajola, M., Nousiainen, U., & Vapalahti, M. P. (1990) · Annals of Neurology · doi:10.1002/ana.410270310 · Cited by 50
Ko, D., Kufta, C. V., Scaffidi, D., & Sato, S. (1998) · Neurosurgery · doi:10.1097/00006123-199802000-00142 · Cited by 49 · cited 3×
“…obtained from simultaneous EEG and MEG re- cordings yielded controversial results (Baillet et al., 2002; Diekmann et al., 1995; Ebersole, 1997; Ebersole et al., 1993; Ko et al., 1995; Ko et al., 1998; Merlet et al., 1997; Nakasoto et al., 1992; Nakasoto et al., 1994; Sutherling et al., 1988a).”
BackgroundResultStefan, H., Schneider, S., Abraham‐Fuchs, K., Pawlik, G., Feistel, H., Bauer, J. M., Neubauer, U., Huk, W. J., & Holthoff‐Detto, V. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90150-3 · Cited by 49 · cited 2×
“, 1989) and to document spike propagation between mesiobasal and lateral temporal lobe structures noninvasively (Stefan et al., 1991; Sutherling and Barth, 1989).”
BackgroundFast and Slow Magnetic Phenomena in Focal Epileptic Seizures
Barth, D. S., Sutherling, W. W., & Beatty, J. (1984) · Science · doi:10.1126/science.6436979 · Cited by 46 · cited 1×
“…close proximity to various structural lesions, which helped to better define the spatial relationship between these lesions and the irritative zone (Barth et al., 1984a; Baumgartner et al., 2000b; Knowlton et al., 1997; Morioka et al., 1999; Morioka et al., 2000; Ricci et al., 1985; Stefan et al.,…”
BackgroundThe Functional Organization of the Interictal Spike Complex in Benign Rolandic Epilepsy
Baumgartner, C., Graf, M. R., Doppelbauer, A., Serles, W., Lindinger, G., Olbrich, A., Bacher, J., Pataraia, E., Almer, G., & Lischka, A. J. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb00548.x · Cited by 43 · cited 1×
“Conversely, scalp-EEG dipole modeling of interictal spikes has been applied successfully in a large number of studies (Baumgartner et al., 1995; Baumgartner et al., 1996; Boon et al., 1997a; Boon et al., 1997b; Boon and D’Have, 1995; Ebersole, 1991, 1994; Ebersole, 2000; Ebersole et al., 1996;…”
Self-citationMackert, B., Wübbeler, G., Burghoff, M., Marx, P., Trahms, L., & Curio, G. (1999) · Neuroscience Letters · doi:10.1016/s0304-3940(99)00657-6 · Cited by 42 · cited 1×
“In humans, DC-MEG has been used to demonstrate similar findings in migraine (Barkley et al., 1990, Bowyer et al., 2001), familial hemiplegic migraine (Gutschalk et al., 2002), and slow shifts produced by evoked responses in normal subjects (Mackert et al., 1999, 2001).”
Neuromagnetic field modeling of multiple brain regions producing interictal spikes in human epilepsy
Barth, D. S., Baumgartner, C., & Sutherling, W. W. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90088-6 · Cited by 38 · cited 1×
“Furthermore, MEG was useful to study the spatiotemporal organization of the interictal spike complex in patients with temporal lobe epilepsy (Barth et al., 1989) and to document spike propagation between mesiobasal and lateral temporal lobe structures noninvasively (Stefan et al., 1991; Sutherling…”
MethodSelf-citationShindo, K., Ikeda, A., Musha, T., Terada, K., Fukuyama, H., Taki, W., Kimura, J., & Shibasaki, H. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01389.x · Cited by 37 · cited 2×
“Thus, in frontal lobe epilepsy, EEG was accurate on a lobar level but not on a sublobar level (Shindo et al., 1998).”
BackgroundMethodLantz, G., Ryding, E., & Rosén, I. (1994) · Journal of Epilepsy · doi:10.1016/0896-6974(94)90009-4 · Cited by 37 · cited 3×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
BackgroundOchi, A., Otsubo, H., Shirasawa, A., Hunjan, A., Sharma, R. K., Bettings, M., Rutka, J. T., Kamijo, K., Yamazaki, T., Wilson, S. B., et al. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00208-4 · Cited by 36 · cited 1×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
Intracellular currents of interictal penicillin spikes: Evidence from neuromagnetic mapping
Barth, D. S., Sutherling, W. W., & Beatty, J. (1986) · Brain Research · doi:10.1016/0006-8993(86)91040-1 · Cited by 34 · cited 1×
“(6) In contrast to EEG, MEG is reference-free (Barth et al., 1986a; Cohen and Cuffin, 1983).”
BackgroundMackert, B., Wübbeler, G., Leistner, S., Trahms, L., & Curio, G. (2001) · Neuroreport · doi:10.1097/00001756-200106130-00034 · Cited by 33 · cited 1×
“In humans, DC-MEG has been used to demonstrate similar findings in migraine (Barkley et al., 1990, Bowyer et al., 2001), familial hemiplegic migraine (Gutschalk et al., 2002), and slow shifts produced by evoked responses in normal subjects (Mackert et al., 1999, 2001).”
A New Surgical Method for the Treatment of Hemispheric Dysplastic Lesions.
Shimizu, H., Maehara, T., & Arai, N. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb01860.x · Cited by 26
Techniques for DC Magnetoencephalography
Barkley, G. L., Moran, J. E., Takanashi, Y., & Tepley, N. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00006 · Cited by 25 · cited 1×
“MEG does not have this problem, and with care, DC-MEG recordings can be routinely performed (Barkley et al., 1991).”
BackgroundSelf-citationDipole modelling and intracranial EEG recording: Correlation between dipole and ictal onset zone
Boon, P., D’Havé, M., Vandekerckhove, T., Achten, E., Adam, C., Clémenceau, S., Baulac, M., Goossens, L., Calliauw, L., & Reuck, J. D. (1997) · Acta Neurochirurgica · doi:10.1007/bf01412000 · Cited by 25 · cited 6×
“Other laboratories subsequently confirmed these findings (Baumgartner et al., 1995; Boon et al., 1997a; Boon and D’Have, 1995; Lantz et al., 1996; Merlet et al., 1996).”
BackgroundMethodResultInfluentialN-acetyltransferase-2 polymorphism in Parkinson's disease: the Rotterdam study
Harhangi, B. S., Oostra, B. A., Heutink, P., van Duijn, C. M., Albert Hofman, D., & Breteler, M. M. B. (1999) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.67.4.518 · Cited by 25
Ochi, A., Otsubo, H., Chitoku, S., Hunjan, A., Sharma, R. K., Rutka, J. T., Chuang, S. H., Kamijo, K., Yamazaki, T., & Snead, O. C. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.27000.x · Cited by 23 · cited 3×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
BackgroundTwo Dimensional Inverse Imaging (2DII) of Current Sources in Magnetoencephalography
Moran, J. E., & Tepley, N. (2000) · Brain Topography · doi:10.1023/a:1023441924015 · Cited by 19 · cited 1×
“Recently distributed source models calculating the three-dimensional current density distribution have become available, which provide information on the spatial extent of epileptic activity (Fuchs et al., 1999; Michel et al., 1999, Moran and Tepley, 2000).”
BackgroundMagnetoencephalography in clinical epileptology and Epilepsy research
Baumgartner, C., & Deecke, L. (1990) · Brain Topography · doi:10.1007/bf01140589 · Cited by 16
Self-citationLangston, J. W., Forno, L. S., Tetrud, J., Reeves, A. G., Kaplan, J. A., & Karluk, D. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199910)46:4 · Cited by 1 · cited 2×
“…localizations showed good agreement with the results obtained from invasive EEG recordings (Ebersole, 1999; Ko et al., 1998; Knowlton et al., 1997; Minassian et al., 1999; Morioka et al., 2000; Nakasoto et al., 1994; Otsubo et al., 1999; Paetau et al., 1994; Rose et al., 1987; Smith et al.,…”
BackgroundResult
Cited by
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Herbet, G., & Duffau, H. (2020) · Physiological Reviews · doi:10.1152/physrev.00033.2019 · Cited by 295
Metadata
- Authors
- Barkley, G. L., & Baumgartner, C.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-05
- Volume
- 20
- Issue
- 3
- Pages
- 163-178
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2042578958
- Cited by
- 202
- References
- 92
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.