MEG and EEG in Epilepsy
The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Abstract
Both EEG and magnetoencephalogram (MEG), with a time resolution of 1 ms or less, provide unique neurophysiologic data not obtainable by other neuroimaging techniques. MEG has now emerged as a mature clinical technology. While both EEG and MEG can be performed with more than 100 channels, MEG recordings with 100 to 300 channels are more easily done because of the time needed to apply a large number of EEG electrodes. EEG has the advantage of the long-term video EEG recordings, which facilitates extensive temporal sampling across all periods of the sleep/wake cycle. MEG and EEG seem to complement each other for the detection of interictal epileptiform discharges, because some spikes can be recorded only on MEG but not on EEG and vice versa. Most studies indicate that MEG seems to be more sensitive for neocortical spike sources. Both EEG and MEG source localizations show excellent agreement with invasive electrical recordings, clarify the spatial relationship between the irritative zone and structural lesions, and finally, attribute epileptic activity to lobar subcompartments in temporal lobe and to a lesser extent in extratemporal epilepsies. In temporal lobe epilepsy, EEG and MEG can differentiate between patients with mesial, lateral, and diffuse seizure onsets. MEG selectively detects tangential sources. EEG measures both radial and tangential activity, although the radial components dominate the EEG signals at the scalp. Thus, while EEG provides more comprehensive information, it is more complicated to model due to considerable influences of the shape and conductivity of the volume conductor. Dipole localization techniques favor MEG due to the higher accuracy of MEG source localization compared to EEG when using the standard spherical head shape model. However, if special care is taken to address the above issues and enhance the EEG, the localization accuracy of EEG and MEG actually are comparable, although these surface EEG analytic techniques are not typically approved for clinical use in the United States. MEG dipole analysis is approved for clinical use and thus gives information that otherwise usually requires invasive intracranial EEG monitoring. There are only a few dozen whole head MEG units in operation in the world. While EEG is available in every hospital, specialized EEG laboratories capable of source localization techniques are nearly as scarce as MEG facilities. The combined use of whole-head MEG systems and multichannel EEG in conjunction with advanced source modeling techniques is an area of active development and will allow a better noninvasive characterization of the irritative zone in presurgical epilepsy evaluation. Finally, additional information on epilepsy may be gathered by either MEG or EEG analysis of data beyond the usual bandwidths used in clinical practice, namely by analysis of activity at high frequencies and near-DC activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“However, Hämäläinen et al. (1993) pointed out that the current dipoles from the implanted depth electrodes in the study of Cohen et al. (1990) were nearly radial, decreasing the signal-to-noise ratio of MEG.”
BackgroundBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Llinás, R. R., Ribary, U., Jeanmonod, D., Kronberg, E., & Mitra, P. P. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.26.15222 · Cited by 1,388 · cited 2×
“…from MEG and primarily intracranial EEG recordings that higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba…”
BackgroundA standardized boundary element method volume conductor model
Fuchs, M., Kastner, J., Wagner, M., Hawes, S., & Ebersole, J. S. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00030-5 · Cited by 999 · cited 3×
“EEG source localizations can be considerably improved by the use of realistic head shape and brain models, which are especially relevant for epileptic activity arising from the temporal lobes (Ebersole et al., 1996; Fuchs et al., 1998a; Fuchs et al., 2001; Fuchs et al., 2002; Roth et al., 1993; Roth et al., 1997).”
BackgroundMethodCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 1×
“Magnetoencephalographic (MEG) recordings were first made by David Cohen (Cohen, 1968, 1972).”
MethodStaba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666 · cited 1×
“…higher frequency activity is associated with cognitive processing (Kissler et al., 2000; Llinas et al., 1999; Stam et al., 2002; Tallon-Baudry et al., 1997) and epilepsy (Allen et al., 1992; Bragin et al., 1999; Fisher et al., 1992; Staba et al., 2002; Timofeev et al., 1992; Wendling et al., 2003).”
BackgroundCooper, R., Winter, A. L., Crow, H. J., & Walter, W. G. (1965) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(65)90088-x · Cited by 561 · cited 2×
“…to 4 cm2 of synchronized epileptic activity involving the lateral neocortex was necessary to produce a detectable MEG signal at the scalp (Baumgartner et al., 1992; Mikuni et al., 1997; Oishi et al., 2002), which is smaller than the classical 6 cm2 proposed for the scalp-EEG (Cooper et al., 1965).”
BackgroundLinear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436 · cited 5×
“Thus, distributed source models could add additional information on the spatial distribution of the irritative zone (Fuchs et al., 1999; Michel et al., 1999).”
BackgroundInfluentialEffectiveness of Multiple EEGs in Supporting the Diagnosis of Epilepsy: An Operational Curve
Salinsky, M., Kanter, R., & Dasheiff, R. M. (1987) · Epilepsia · doi:10.1111/j.1528-1157.1987.tb03652.x · Cited by 416 · cited 1×
“When interictal epileptiform activity is present, it can be identified in the first EEG in 50%, in 84% by the third EEG, and in 92% by the fourth (Salinsky et al., 1987).”
BackgroundEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413 · cited 4×
“…reported accurate localization of the irritative zone in patients with extratemporal epilepsies using source localization techniques (Boon et al., 1997a; Boon et al., 1997b; Lantz et al., 1994; Lantz et al., 2003; Merlet and Gotman, 1999; Ochi et al., 2000; Ochi et al., 2001a; Shindo et al., 1998).”
BackgroundInfluential
Cited by
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Herbet, G., & Duffau, H. (2020) · Physiological Reviews · doi:10.1152/physrev.00033.2019 · Cited by 295
Goldenholz, D. M., Ahlfors, S. P., Hämäläinen, M. S., Sharon, D., Ishitobi, M., Vaina, L. M., & Stufflebeam, S. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20571 · Cited by 266
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
“The system could also have significant clinical application, coupling reduced operating costs with the potential to provide improved assessment of the development of diseases, such as epilepsy and schizophrenia (Barkley and Baumgartner, 2003; Robson et al., 2016).”
BackgroundDiagnostic test utilization in evaluation for resective epilepsy surgery in children
Jayakar, P., Gaillard, W. D., Tripathi, M., Libenson, M. H., Mathern, G. W., Cross, J. H., & The Task Force for Paediatric Epilepsy Surgery, C. F. P. (2014) · Epilepsia · doi:10.1111/epi.12544 · Cited by 223
“In general, EEG source imaging and MEG have been shown to be complementary, with MEG being more sensitive to tangential sources and EEG to radially oriented sources.(17,18) MEG is able to define smaller foci (4–8 cm(2)) compared to EEG (10–15 cm(2)).”
BackgroundFull-band EEG (FbEEG): an emerging standard in electroencephalography
Vanhatalo, S., Voipio, J., & Kaila, K. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.09.015 · Cited by 196
128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
“Concerning neocortical epilepsy, for which MEG is supposed to be more useful (Barkley and Baumgartner, 2003), 92% yield was reported by Knowlton et al. (1997) (12 patients) and 100% by Stefan et al. (2003) (22 patients).”
BackgroundThe value of multichannel MEG and EEG in the presurgical evaluation of 70 epilepsy patients
Knake, S., Halgren, E., Shiraishi, H., Hara, K., Hamer, H. M., Grant, P. E., Carr, V. A., Foxe, D., Camposano, S., Busa, E., et al. (2006) · Epilepsy Research · doi:10.1016/j.eplepsyres.2006.01.001 · Cited by 165
“The evolution of MEG over the last decade, especially the advent of whole-head systems, has provided additional ability to define the irritative zone (Barkley and Baumgartner, 2003; Pataraia et al., 2004; Baumgartner, 2004).”
BackgroundWearable OPM-MEG: a changing landscape for epilepsy
Pedersen, M., Abbott, D. F., & Jackson, G. D. (2022) · Epilepsia · doi:10.1111/epi.17368 · Cited by 68
Elisevich, K., Shukla, N., Moran, J. E., Smith, B., Schultz, L., Mason, K., Barkley, G. L., Tepley, N., Gumenyuk, V., & Bowyer, S. M. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.02990.x · Cited by 66
Self-citationFull-Band EEG (FbEEG): A New Standard for Clinical Electroencephalography
Vanhatalo, S., Voipio, J., & Kaila, K. (2005) · Clinical EEG and Neuroscience · doi:10.1177/155005940503600411 · Cited by 47
Metadata
- Authors
- Barkley, G. L., & Baumgartner, C.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-05
- Volume
- 20
- Issue
- 3
- Pages
- 163-178
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2042578958
- Cited by
- 202
- References
- 92
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.