Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision

Michel, Christoph M., Lantz, Göran, Spinelli, Laurent, de Peralta, Rolando Grave, Landis, Theodor, Seeck, Margitta·2004·Journal of Clinical Neurophysiology

Abstract

The authors evaluated the feasibility, clinical yield, and localization precision of high-resolution EEG source imaging of interictal epileptic activity. A consecutive series of 44 patients with intractable epilepsy of various causes, who underwent a comprehensive presurgical epilepsy evaluation, were subjected to a 128-channel EEG recording. A standardized source imaging procedure constrained to the individual gray matter was applied to the averaged spikes of each patient. In 32 patients, the presurgical workup identified a focal epileptogenic area. The 128-channel EEG source imaging correctly localized this area in 30 of these patients (93.7%). Imprecise localization was explained by simplifications of the recordings and analysis procedure, which was accepted for the benefit of speed and standardization. In a subgroup of 24 patients who underwent operations, the sublobar precision of the 128-channel EEG source imaging was evaluated by calculating the distance of the source maximum to the resected area. This analysis revealed zero distance in 19 cases (79%). The authors conclude that high-resolution interictal EEG source imaging is a valuable noninvasive functional neuroimaging technique. The speed, ease, flexibility, and low cost of this technique warrant its use in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004691-200403000-00001

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 183

Metadata

Authors
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M.
Venue
Journal of Clinical Neurophysiology
Published
2004-03
Volume
21
Issue
2
Pages
71-83
ISSN
0736-0258 (ISSN-L)
OpenAlex
W2084053174
Cited by
183
References
1
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision. https://app.cochat.ai/papers/10.1097/00004691-200403000-00001
The paper
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004). 128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-200403000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.