128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
The authors evaluated the feasibility, clinical yield, and localization precision of high-resolution EEG source imaging of interictal epileptic activity. A consecutive series of 44 patients with intractable epilepsy of various causes, who underwent a comprehensive presurgical epilepsy evaluation, were subjected to a 128-channel EEG recording. A standardized source imaging procedure constrained to the individual gray matter was applied to the averaged spikes of each patient. In 32 patients, the presurgical workup identified a focal epileptogenic area. The 128-channel EEG source imaging correctly localized this area in 30 of these patients (93.7%). Imprecise localization was explained by simplifications of the recordings and analysis procedure, which was accepted for the benefit of speed and standardization. In a subgroup of 24 patients who underwent operations, the sublobar precision of the 128-channel EEG source imaging was evaluated by calculating the distance of the source maximum to the resected area. This analysis revealed zero distance in 19 cases (79%). The authors conclude that high-resolution interictal EEG source imaging is a valuable noninvasive functional neuroimaging technique. The speed, ease, flexibility, and low cost of this technique warrant its use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909 · cited 1×
“It has not been until recently that EEG systems with the same high number of sensors and very fast scalp application have become available (Oostenveld and Praamstra, 2001; Suarez et al., 2000; Tucker, 1993).”
BackgroundPresurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669 · cited 6×
“It has repeatedly been argued that high-density EEG recordings are clinically not feasible because of the lengthy procedure to apply a large number of electrodes (King et al., 2000; Rosenow and Lüders, 2001).”
BackgroundMethodInfluentialSpatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751 · cited 2×
“It has not been until recently that EEG systems with the same high number of sensors and very fast scalp application have become available (Oostenveld and Praamstra, 2001; Suarez et al., 2000; Tucker, 1993).”
BackgroundO'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W. (1998) · Neurology · doi:10.1212/wnl.50.2.445 · Cited by 530 · cited 1×
“Similar sensitivity values are reported for ictal/interictal SPECT comparisons, if subtraction analysis was applied (Kaiboriboon et al., 2002; O’Brien et al., 1998).”
ResultLinear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436 · cited 2×
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413 · cited 7×
“Validation and application of the localization method in epileptic EEG has been shown in previous studies (Grave de Peralta and Gonzalez, 2002; Lantz et al., 2001a, 2003a).”
BackgroundMethodInfluentialSelf-citationThe Relative Contributions of MRI, SPECT, and PET Imaging in Epilepsy
Spencer, S. S. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb05990.x · Cited by 379 · cited 1×
“Studies on its sensitivity revealed values up to 85% (Da Silva et al., 1997), although there is evidence that the yield is less notable if the MRI does not show a structural lesion (Spencer, 1994).”
BackgroundEntorhinal‐Hippocampal Interactions in Medial Temporal Lobe Epilepsy
Spencer, S. S., & Spencer, D. D. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02502.x · Cited by 363
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349 · cited 2×
“EEG source localization precision crucially depends on the number of electrodes, from which the EEG is recorded (Lantz et al., 2003a; Liu et al., 2002).”
BackgroundMenendez, R. G. D. P., Andino, S. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 348 · cited 1×
“…the electrical activity in the brain we used a recently developed distributed linear inverse solution called EPIFOCUS (Grave de Peralta and Gonzalez, 2002; Grave de Peralta et al., 2001), which can be interpreted as the probability of a focal source at any given point in a discrete solution space.”
MethodSelf-citationAlarcon, G., Guy, C. N., Binnie, C. D., Walker, S. R., Elwes, R. D., & Polkey, C. E. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.4.435 · Cited by 319 · cited 2×
“It is well known that propagated sources can already be involved at the time point of the peak of the spike on the scalp (Alarcon et al., 1994, 1997), and it has been shown that best localization is achieved at around 50% of the rising phase of the spike (Huppertz et al., 2001; Scherg et al., 1999).”
BackgroundMagnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304 · cited 3×
“Knowlton et al. (1997) reported 50% yield for temporal lobe epilepsy, and Stefan et al. (2003) reported 86.2% yield.”
BackgroundResultInfluentialIntracranial EEG Substrates of Scalp Ictal Patterns from Temporal Lobe Foci
Pacia, S. V., & Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01233.x · Cited by 253 · cited 1×
“Only if this epileptic activity propagates into the basal temporal cortex, such as the entorhinal cortex, is a sufficient area activated to produce scalp EEG potentials (Pacia and Ebersole, 1997).”
BackgroundAlarcon, G. (1997) · Brain · doi:10.1093/brain/120.12.2259 · Cited by 248 · cited 1×
“It is well known that propagated sources can already be involved at the time point of the peak of the spike on the scalp (Alarcon et al., 1994, 1997), and it has been shown that best localization is achieved at around 50% of the rising phase of the spike (Huppertz et al., 2001; Scherg et al., 1999).”
BackgroundError bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233 · cited 2×
“Because some analysis of real data as well as modeling work suggested that the precision of EEG source localization is similar to or even better than that of the MEG if the same number of sensors are used (Cuffin et al., 1991; Liu et al., 2002; Malmivuo et al., 1997; Mosher et al., 1993), these new, fast, high-density…”
BackgroundDepth electrode investigations in patients with bitemporal epileptiform abnormalities
So, N., Gloor, P., Quesney, L. F., Jones‐Gotman, M., Olivier, A., & Andermann, F. (1989) · Annals of Neurology · doi:10.1002/ana.410250502 · Cited by 219 · cited 1×
“Although the irritative zone in most cases is concordant with the seizure onset zone (Blume et al., 1993; Chung et al., 1991; Lantz et al., 1997b), this is not necessarily always the case (Alarcon et al., 1994; Hirsch et al., 1991; So et al., 1989).”
BackgroundBarkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202 · cited 1×
“Concerning neocortical epilepsy, for which MEG is supposed to be more useful (Barkley and Baumgartner, 2003), 92% yield was reported by Knowlton et al. (1997) (12 patients) and 100% by Stefan et al. (2003) (22 patients).”
BackgroundA Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., et al. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00800.x · Cited by 193 · cited 2×
“al., 2002; Stefan et al., 2000; Wheless et al., 1999), in particular with the development of large-array biomagnetometers that allow quick sampling of the brain magnetic activity with high spatial resolution.”
BackgroundElectromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182 · cited 2×
“2) Transformation of the MRI to the best-fitting sphere using the SMAC method (Spinelli et al., 2000).”
MethodSelf-citationDefining Epileptogenic Foci: Past, Present, Future
Ebersole, J. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199711000-00003 · Cited by 173 · cited 2×
“Nowadays, computer-assisted EEG source analysis methods exist, which allow a more precise determination of the underlying sources than simple visual inspection (Ebersole, 1997).”
BackgroundLantz, G., Spinelli, L., Seeck, M., de Peralta Menendez, R. G., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 170
Self-citationMultiple Source Analysis of Interictal Spikes: Goals, Requirements, and Clinical Value
Scherg, M., Bast, T., & Berg, P. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00003 · Cited by 160 · cited 5×
“During the last decade, such source localization methods have repeatedly been applied to ictal or interictal epileptic activity with remarkable success (Blanke et al., 2000; Boon et al., 2000, 2002; Ebersole, 2000a, b; Fuchs et al., 1999; Krings et al., 1998; Lantz et al., 1997a, 1999, 2001a, b; Merlet and Gotman, 199…”
BackgroundInfluentialSensitivity distributions of EEG and MEG measurements
Malmivuo, J. A., Suihko, V., & Eskola, H. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554766 · Cited by 150 · cited 2×
“Because some analysis of real data as well as modeling work suggested that the precision of EEG source localization is similar to or even better than that of the MEG if the same number of sensors are used (Cuffin et al., 1991; Liu et al., 2002; Malmivuo et al., 1997; Mosher et al., 1993), these new, fast, high-density…”
BackgroundLantz, G., Michel, C. M., Pascual-Marqui, R. D., Spinelli, L., Seeck, M., Seri, S., Landis, T., & Rosén, I. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(96)96551-0 · Cited by 148 · cited 3×
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundSelf-citationReliability of dipole models of epileptic spikes
Merlet, I., & Gotman, J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00062-5 · Cited by 143 · cited 2×
“During the last decade, such source localization methods have repeatedly been applied to ictal or interictal epileptic activity with remarkable success (Blanke et al., 2000; Boon et al., 2000, 2002; Ebersole, 2000a, b; Fuchs et al., 1999; Krings et al., 1998; Lantz et al., 1997a, 1999, 2001a, b; Merlet and Gotman, 199…”
BackgroundEEG Source Localization and Imaging Using Multiple Signal Classification Approaches
Mosher, J. C., Baillet, S., & Leahy, R. M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00004 · Cited by 137
Identification of Frontal Lobe Epileptic Foci in Children Using Positron Emission Tomography
da Silva, E. A., Chugani, D. C., Muzik, O., & Chugani, H. T. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01217.x · Cited by 131 · cited 1×
“Studies on its sensitivity revealed values up to 85% (Da Silva et al., 1997), although there is evidence that the yield is less notable if the MRI does not show a structural lesion (Spencer, 1994).”
BackgroundNeuromagnetic Recordings in Temporal Lobe Epilepsy
Baumgartner, C., Pataraia, E., Lindinger, G., & Deecke, L. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200003000-00007 · Cited by 130 · cited 2×
“Source localization with magnetoencephalography (MEG) has received somewhat more attention (Baumgartner et al., 2000a, b; King et al.,”
BackgroundChung, M., Walczak, T. S., Lewis, D. V., Dawson, D. V., & Radtke, R. A. (1991) · Epilepsia · doi:10.1111/j.1528-1157.1991.tb05244.x · Cited by 128 · cited 1×
“Although the irritative zone in most cases is concordant with the seizure onset zone (Blume et al., 1993; Chung et al., 1991; Lantz et al., 1997b), this is not necessarily always the case (Alarcon et al., 1994; Hirsch et al., 1991; So et al., 1989).”
BackgroundTests of EEG localization accuracy using implanted sources in the human brain
Cuffin, B. N., Cohen, D., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J. R., Kennedy, J. G., & Schomer, D. L. (1991) · Annals of Neurology · doi:10.1002/ana.410290204 · Cited by 124 · cited 2×
“…suggested that the precision of EEG source localization is similar to or even better than that of the MEG if the same number of sensors are used (Cuffin et al., 1991; Liu et al., 2002; Malmivuo et al., 1997; Mosher et al., 1993), these new, fast, high-density EEG systems present an interesting…”
BackgroundSpatiotemporal EEG Analysis and Distributed Source Estimation in Presurgical Epilepsy Evaluation
Michel, C. M., de Peralta, R. G., Lantz, G., Andino, S. G., Spinelli, L., Blanke, O., Landis, T., & Seeck, M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00005 · Cited by 118 · cited 3×
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundSelf-citationNoninvasive Localization of Epileptogenic Foci by EEG Source Modeling
Ebersole, J. S. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01531.x · Cited by 104 · cited 2×
“As suggested by Ebersole (2000b), one must check whether different voltage topographies appear over the course of the spike, indicating propagation.”
BackgroundResultComparison of bitemporal and unitemporal epilepsy defined by depth electroencephalography
Hirsch, L. J., Spencer, S. S., Williamson, P. D., et al. (1991) · Annals of Neurology · doi:10.1002/ana.410300305 · Cited by 87 · cited 1×
“Although the irritative zone in most cases is concordant with the seizure onset zone (Blume et al., 1993; Chung et al., 1991; Lantz et al., 1997b), this is not necessarily always the case (Alarcon et al., 1994; Hirsch et al., 1991; So et al., 1989).”
BackgroundMagnetoencephalography in presurgical epilepsy evaluation
Pataraia, E., Baumgartner, C., Lindinger, G., & Deecke, L. (2002) · Neurosurgical Review · doi:10.1007/s10143-001-0197-2 · Cited by 80 · cited 1×
“Source localization with magnetoencephalography (MEG) has received somewhat more attention (Baumgartner et al., 2000a, b; King et al., 2000; Knowlton et al., 1997; Paetau et al., 1992; Pataraia et al., 2002; Stefan et al., 2000; Wheless et al., 1999), in particular with the development of large-array biomagnetometers…”
BackgroundMagnetoencephalographic localization of epileptic cortex—impact on surgical treatment
Paetau, R., Kajola, M., Karhu, J., Nousiainen, U., Partanen, J. V., Tiihonen, J., Vapalahti, M. P., & Hari, R. (1992) · Annals of Neurology · doi:10.1002/ana.410320119 · Cited by 78 · cited 1×
“Source localization with magnetoencephalography (MEG) has received somewhat more attention (Baumgartner et al., 2000a, b; King et al., 2000; Knowlton et al., 1997; Paetau et al., 1992; Pataraia et al., 2002; Stefan et al., 2000; Wheless et al., 1999), in particular with the development of large-array biomagnetometers…”
BackgroundHuppertz, H., Hof, E., Klisch, J., Wagner, M., Lücking, C. H., & Kristeva-Feige, R. (2001) · NeuroImage · doi:10.1006/nimg.2000.0680 · Cited by 74 · cited 4×
“realistic head models, EEG source localization in epilepsy is now possible with very high localizing precision (Herrendorf et al., 2000; Huppertz et al., 2001; Lantz et al., 2003a; Waberski et al., 2000).”
BackgroundInfluentialKaiboriboon, K., Lowe, V. J., Chantarujikapong, S., & Hogan, R. E. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.21201.x · Cited by 74 · cited 1×
“Similar sensitivity values are reported for ictal/interictal SPECT comparisons, if subtraction analysis was applied (Kaiboriboon et al., 2002; O’Brien et al., 1998).”
ResultMagnetoencephalography in Extratemporal Epilepsy
Stefan, H., Hummel, C., Hopfengärtner, R., Pauli, E., Tilz, C., Ganslandt, O., Kober, H., Möller, M., & Buchfelder, M. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200003000-00008 · Cited by 74 · cited 2×
“al., 2002; Stefan et al., 2000; Wheless et al., 1999), in particular with the development of large-array biomagnetometers that allow quick sampling of the brain magnetic activity with high spatial resolution.”
BackgroundLantz, G., Menéndez, R. G. D. P., Andino, S. L. G., & Michel, C. M. (2001) · Brain Topography · doi:10.1023/a:1012996930489 · Cited by 72 · cited 1×
“…the electrical activity in the brain we used a recently developed distributed linear inverse solution called EPIFOCUS (Grave de Peralta and Gonzalez, 2002; Grave de Peralta et al., 2001), which can be interpreted as the probability of a focal source at any given point in a discrete solution space.”
MethodSelf-citationIctal Source Localization in Presurgical Patients With Refractory Epilepsy
Boon, P., D’Havé, M., Vanrumste, B., Hoey, G. V., Vonck, K. E. J., Walleghem, P. V., Caemaert, J., Achten, E., & Reuck, J. D. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00009 · Cited by 67 · cited 1×
“Boon et al. (2002) reported around 9 hours of calculation time with specific software on dedicated hardware to localize single equivalent dipoles of ictal activity and the authors correctly asked the question of whether it is feasible to invest such efforts on a routine basis.”
BackgroundTemporal and spatial determination of EEG-seizure onset in the frequency domain
Blanke, O., Lantz, G., Seeck, M., Spinelli, L., de Peralta, R. G., Thut, G., Landis, T., & Michel, C. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00251-0 · Cited by 65 · cited 1×
“However, direct source analysis of the seizure EEG, as we proposed in earlier studies (Blanke et al., 2000; Lantz et al., 1999, 2001b), and comparison with the localization of the interictal activity would be preferable.”
MethodSelf-citationMagnetoencephalography in Focal Epilepsy
Baumgartner, C., Pataraia, E., Lindinger, G., & Deecke, L. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01533.x · Cited by 59 · cited 2×
“Source localization with magnetoencephalography (MEG) has received somewhat more attention (Baumgartner et al., 2000a, b; King et al.,”
BackgroundDipole‐Source Analysis in a Realistic Head Model in Patients with Focal Epilepsy
Herrendorf, G., Steinhoff, B. J., Kolle, R., Baudewig, J., Waberski, T. D., Buchner, H., & Paulus, W. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01508.x · Cited by 54 · cited 2×
“realistic head models, EEG source localization in epilepsy is now possible with very high localizing precision (Herrendorf et al., 2000; Huppertz et al., 2001; Lantz et al., 2003a; Waberski et al., 2000).”
BackgroundKrings, T., Chiappa, K. H., Cuffin, B. N., Buchbinder, B. R., & Cosgrove, G. R. (1998) · Annals of Neurology · doi:10.1002/ana.410440114 · Cited by 51 · cited 3×
“The point-to-set distance was calculated as the Euclidian distance of the solution point with the source maximum to the closest point within the resected area (Krings et al., 1998; Lantz et al., 2003a).”
BackgroundMethodSpace-oriented segmentation and 3-dimensional source reconstruction of ictal EEG patterns
Lantz, G., Michel, C. M., Seeck, M., Blanke, O., Spinelli, L., Thut, G., Landis, T., & Rosén, I. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00479-5 · Cited by 49 · cited 5×
“2 in Lantz et al., 2001c).”
BackgroundMethodInfluentialSelf-citationSeri, S., Cerquiglini, A., Pisani, F., Michel, C. M., Pascual-Marqui, R. D., & Curatolo, P. (1998) · Journal of Child Neurology · doi:10.1177/088307389801300106 · Cited by 43 · cited 2×
“During the last decade, such source localization methods have repeatedly been applied to ictal or interictal epileptic activity with remarkable success (Blanke et al., 2000; Boon et al., 2000, 2002; Ebersole, 2000a, b; Fuchs et al., 1999; Krings et al., 1998; Lantz et al., 1997a, 1999, 2001a, b; Merlet and Gotman, 199…”
BackgroundSelf-citationSource Reconstruction of Mesial‐Temporal Epileptiform Activity: Comparison of Inverse Techniques
Waberski, T. D., Gobbelé, R., Herrendorf, G., Steinhoff, B. J., Kolle, R., Fuchs, M., Paulus, W., & Buchner, H. (2000) · Epilepsia · doi:10.1111/j.1499-1654.2000.001574.x · Cited by 38 · cited 2×
“realistic head models, EEG source localization in epilepsy is now possible with very high localizing precision (Herrendorf et al., 2000; Huppertz et al., 2001; Lantz et al., 2003a; Waberski et al., 2000).”
BackgroundDipole reconstruction as a method for identifying patients with mesolimbic epilepsy
Lantz, G., Ryding, E., & Rosén, I. (1997) · Seizure · doi:10.1016/s1059-1311(97)80078-7 · Cited by 26 · cited 3×
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundSelf-citationGenetic Localization of the Ca2+ Channel Gene CACNG2 Near SCA10 on Chromosome 22q13
Burgess, D. L., Matsuura, T., Ashizawa, T., & Noebels, J. L. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01500.x · Cited by 22
Categorization of interictal epileptiform potentials using a graph-theoretic method
Lantz, G., Wahlberg, P., Salomonsson, G., & Rosén, I. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00081-9 · Cited by 7 · cited 1×
“Automatic spike detection (Gotman, 1985) and spike classification (Lantz et al., 1998) algorithms could further facilitate the task.”
BackgroundSelf-citationLocalisation de sources distribuées et comparaison avec PIRM fonctionnelle
Lantz, G., Spinelli, L., Menéndez, R. G. D. P., Seeck, M., & Michel, C. M. (2001) · Epileptic Disorders · doi:10.1684/j.1950-6945.2001.tb00411.x · Cited by 2 · cited 5×
“2 in Lantz et al., 2001c).”
BackgroundMethodInfluentialSelf-citation
Cited by
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Self-citationTowards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“Source estimation was performed using the linear distributed inverse solution known as LAURA (local autoregressive average; Grave de Peralta et al., 2004; Michel et al., 2004).”
BackgroundMethodInfluentialSelf-citationEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Metadata
- Authors
- Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2004-03
- Volume
- 21
- Issue
- 2
- Pages
- 71-83
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2084053174
- Cited by
- 183
- References
- 51
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.