128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
The authors evaluated the feasibility, clinical yield, and localization precision of high-resolution EEG source imaging of interictal epileptic activity. A consecutive series of 44 patients with intractable epilepsy of various causes, who underwent a comprehensive presurgical epilepsy evaluation, were subjected to a 128-channel EEG recording. A standardized source imaging procedure constrained to the individual gray matter was applied to the averaged spikes of each patient. In 32 patients, the presurgical workup identified a focal epileptogenic area. The 128-channel EEG source imaging correctly localized this area in 30 of these patients (93.7%). Imprecise localization was explained by simplifications of the recordings and analysis procedure, which was accepted for the benefit of speed and standardization. In a subgroup of 24 patients who underwent operations, the sublobar precision of the 128-channel EEG source imaging was evaluated by calculating the distance of the source maximum to the resected area. This analysis revealed zero distance in 19 cases (79%). The authors conclude that high-resolution interictal EEG source imaging is a valuable noninvasive functional neuroimaging technique. The speed, ease, flexibility, and low cost of this technique warrant its use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909 · cited 1×
“It has not been until recently that EEG systems with the same high number of sensors and very fast scalp application have become available (Oostenveld and Praamstra, 2001; Suarez et al., 2000; Tucker, 1993).”
BackgroundPresurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669 · cited 6×
“It has repeatedly been argued that high-density EEG recordings are clinically not feasible because of the lengthy procedure to apply a large number of electrodes (King et al., 2000; Rosenow and Lüders, 2001).”
BackgroundMethodInfluentialSpatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751 · cited 2×
“It has not been until recently that EEG systems with the same high number of sensors and very fast scalp application have become available (Oostenveld and Praamstra, 2001; Suarez et al., 2000; Tucker, 1993).”
BackgroundO'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W. (1998) · Neurology · doi:10.1212/wnl.50.2.445 · Cited by 530 · cited 1×
“Similar sensitivity values are reported for ictal/interictal SPECT comparisons, if subtraction analysis was applied (Kaiboriboon et al., 2002; O’Brien et al., 1998).”
ResultLinear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436 · cited 2×
“Single-spike EEG source localization is principally feasible and can lead to fairly stable results if the signal-to-noise ratio is sufficient (Fuchs et al., 1999; Lantz et al., 1997a, 2001a, 2003a; Michel et al., 1999; Scherg et al., 1999).”
BackgroundEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413 · cited 7×
“Validation and application of the localization method in epileptic EEG has been shown in previous studies (Grave de Peralta and Gonzalez, 2002; Lantz et al., 2001a, 2003a).”
BackgroundMethodInfluentialSelf-citationThe Relative Contributions of MRI, SPECT, and PET Imaging in Epilepsy
Spencer, S. S. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb05990.x · Cited by 379 · cited 1×
“Studies on its sensitivity revealed values up to 85% (Da Silva et al., 1997), although there is evidence that the yield is less notable if the MRI does not show a structural lesion (Spencer, 1994).”
BackgroundEntorhinal‐Hippocampal Interactions in Medial Temporal Lobe Epilepsy
Spencer, S. S., & Spencer, D. D. (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02502.x · Cited by 363
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349 · cited 2×
“EEG source localization precision crucially depends on the number of electrodes, from which the EEG is recorded (Lantz et al., 2003a; Liu et al., 2002).”
BackgroundMenendez, R. G. D. P., Andino, S. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 348 · cited 1×
“…the electrical activity in the brain we used a recently developed distributed linear inverse solution called EPIFOCUS (Grave de Peralta and Gonzalez, 2002; Grave de Peralta et al., 2001), which can be interpreted as the probability of a focal source at any given point in a discrete solution space.”
MethodSelf-citation
Cited by
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Self-citationTowards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“Source estimation was performed using the linear distributed inverse solution known as LAURA (local autoregressive average; Grave de Peralta et al., 2004; Michel et al., 2004).”
BackgroundMethodInfluentialSelf-citationEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Subcortical electrophysiological activity is detectable with high-density EEG source imaging
Seeber, M., Cantonas, L.-M., Hoevels, M., Sesia, T., Visser-Vandewalle, V., & Michel, C. M. (2019) · Nature Communications · doi:10.1038/s41467-019-08725-w · Cited by 294
Self-citationCombining EEG and fMRI: A multimodal tool for epilepsy research
Gotman, J., Kobayashi, E., Bagshaw, A. P., Bénar, C., & Dubeau, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20577 · Cited by 280
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Evaluation of EEG localization methods using realistic simulations of interictal spikes
Grova, C., Daunizeau, J., Lina, J.-M., Bénar, C. G., Benali, H., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.053 · Cited by 233
Brown, C. A., Seymour, B., Boyle, Y., El-Deredy, W., & Jones, A. K. P. (2008) · Pain · doi:10.1016/j.pain.2007.05.022 · Cited by 218
“Similar estimates have been provided from cross-validation studies of epileptic foci localization (Lantz et al., 2003; Michel et al., 2004), which show strong correspondence with PET data (Zumsteg et al., 2005).”
ResultGrouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199
Self-citationScalp EEG is not a Blur: It Can See High Frequency Oscillations Although Their Generators are Small
Zelmann, R., Lina, J. M., Schulze-Bonhage, A., Gotman, J., & Jacobs, J. (2014) · Brain Topography · doi:10.1007/s10548-013-0321-y · Cited by 163
Neuronal networks in children with continuous spikes and waves during slow sleep
Siniatchkin, M., Groening, K., Moehring, J., Moeller, F., Boor, R., Brodbeck, V., Michel, C. M., Rodionov, R., Lemieux, L., & Stephani, U. (2010) · Brain · doi:10.1093/brain/awq183 · Cited by 160
Self-citationEffect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
“Using such high-density EEG recordings, Michel et al. (2004a) demonstrated correct localization on a lobar level in 93.7% of 32 patients.”
BackgroundInfluentialSelf-citationLu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98
Dynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93
“Studies have demonstrated good correlation between sources of inter-ictal spike and epileptogenic regions (Michel et al., 2004; Knowlton et al., 2008).”
BackgroundSohrabpour, A., Lu, Y., Worrell, G., & He, B. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.05.064 · Cited by 89
“Additionally, determining the number of dipoles to be used in an ECD model is not a straightforward process (Michel et al., 2004b).”
BackgroundMethodInfluentialSohrabpour, A., Ye, S., Worrell, G. A., Zhang, W., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616474 · Cited by 59
“Using high-density measurements, ESI techniques can provide quite robust estimates of the cortical activation [28], [29].”
MethodA review on brain imaging techniques for BCI applications
Bhattacharyya, S., Khasnobish, A., Ghosh, P., Mazumder, A., & Tibarewala, D. N. (2017) · Medical Imaging · doi:10.4018/978-1-5225-0571-6.ch012 · Cited by 8
Metadata
- Authors
- Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2004-03
- Volume
- 21
- Issue
- 2
- Pages
- 71-83
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2084053174
- Cited by
- 183
- References
- 51
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.