MR Imaging: Clinical Use of the Inversion Recovery Sequence
The DOI matches its Crossref record.
Abstract
The properties of the inversion recovery (IR) sequence are considered and its use in clinical practice is illustrated. The effect of changing repetition time, inversion time (TI), and echo time; the method of data encoding; the type of data collection; and the method of image processing are analysed. Normal appearances and clinical examples in the central nervous system and the remainder of the body are used to illustrate the many options available with this sequence. The short TI IR sequence has advantages in magnetic resonance imaging of the body, and medium TI sequences are of value in localisation in the brain and in demonstrating contrast enhancement. Long TI sequences can be used in pediatrics and for separating tumour and oedema. Suppression or partial suppression of fat and fluid signals are two useful options with IR sequences. Index Terms: Inversion recovery–Nuclear magnetic resonance, techniques–Nuclear magnetic resonance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Horner, R., Mohiaddin, R., Lowell, D., Shea, S., Burman, E., Longmore, D., & Guz, A. (1989) · European Respiratory Journal · doi:10.1183/09031936.93.02070613 · Cited by 521
Fat Suppression in MR Imaging: Techniques and Pitfalls
Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999) · RadioGraphics · doi:10.1148/radiographics.19.2.g99mr03373 · Cited by 487
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Magnetic Resonance Imaging of Short T2 Components in Tissue
Gatehouse, P. D., & Bydder, G. M. (2003) · Clinical Radiology · doi:10.1053/crad.2003.1157 · Cited by 317
Self-citationRyan, C. F., Lowe, L. A., Li, D., & Fleetham, J. A. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.4.939 · Cited by 247
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“It is therefore more common to combine the STIR technique with fast or turbo spin echo pulse sequences in order to reduce the acquisition time to acceptable limits and this technique is often referred to as turboSTIR.”
InfluentialCohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
T2‐weighted cardiovascular magnetic resonance imaging
Abdel‐Aty, H., Simonetti, O., & Friedrich, M. G. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21028 · Cited by 221
“In addition to fat suppression, the short TI inversion pulse has the added benefit of suppressing signal from any tissues with short T1 (20).”
BackgroundReduction of cortical volume in schizophrenia on magnetic resonance imaging
Harvey, I., Ron, M. A., Boulay, G. D., Wicks, D., Lewis, S. W., & Murray, R. M. (1993) · Psychological Medicine · doi:10.1017/s003329170002537x · Cited by 219
MR Artifacts, Safety, and Quality Control
Zhuo, J., & Gullapalli, R. P. (2006) · RadioGraphics · doi:10.1148/rg.261055134 · Cited by 212
MR spectroscopic imaging: Principles and recent advances
Posse, S., Otazo, R., Dager, S. R., & Alger, J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23945 · Cited by 211
“Alternatives are to presaturate regions that would produce large lipid signal or have unacceptable field homogeneity, or to use lipid nulling using the Short T1 Inversion Recovery (STIR) (7).”
MethodBERNSTEIN, M. A., KING, K. F., & ZHOU, X. J. (2004) · Handbook of MRI Pulse Sequences · doi:10.1016/b978-012092861-3/50021-2 · Cited by 209
Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
Conturo, T. E., & Smith, G. D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150308 · Cited by 205
Magnetic Resonance Imaging of the Bone Marrow in Hematologic Malignancies
Moulopoulos, L. A., & Dimopoulos, M. A. (1997) · Blood · doi:10.1182/blood.v90.6.2127 · Cited by 202
Butts, K., Pauly, J., De Crespigny, A., & Moseley, M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380510 · Cited by 160
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
Metadata
- Authors
- Bydder, G. M., & Young, I. R.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1985-07
- Volume
- 9
- Issue
- 4
- Pages
- 659-675
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W4360754819
- Cited by
- 426
- References
- 0
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.