Blood Flow Imaging by Cine Magnetic Resonance
The DOI matches its Crossref record.
Abstract
A technique for measuring blood flow by whole body nuclear magnetic resonance is described. This method uses imaging gradient profiles that combine even echo rephasing with a field echo sequence to overcome the problem of signal loss from flowing blood. The flow velocity component in any desired direction may be measured by appropriate gradient profile modifications, producing velocity dependent phase shifts that can be displayed by phase mapping. The sequence allows for fast repetition so that flow information may be acquired rapidly from many points in the cardiac cycle and has been used in this mode to observe and measure blood flow in the heart chambers and great vessels. Flow measurements in the femoral artery were also carried out using the same technique; these were compared with similar measurements obtained by Doppler ultrasound. The technique can readily be applied using standard imaging equipment and should prove useful in the clinical assessment of many diseases of the cardiovascular system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Fast, automated, N‐dimensional phase‐unwrapping algorithm
Jenkinson, M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10354 · Cited by 695
Kilner, P. J., Yang, G. Z., Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Circulation · doi:10.1161/01.cir.88.5.2235 · Cited by 592
Self-citationConcomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Encoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
Greitz, D., Wirestam, R., Franck, A., Nordell, B., Thomsen, C., & St�hlberg, F. (1992) · Neuroradiology · doi:10.1007/bf00596493 · Cited by 416
Gaynor, S. L., Diodato, M. D., Prasad, S. M., Ishii, Y., Schuessler, R. B., Bailey, M. S., Damiano, N. R., Bloch, J. B., Moon, M. R., & Damiano, R. J. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.02.044 · Cited by 331
Caruthers, S. D., Lin, S. J., Brown, P., Watkins, M. P., Williams, T. A., Lehr, K. A., & Wickline, S. A. (2003) · Circulation · doi:10.1161/01.cir.0000095268.47282.a1 · Cited by 294
Stanković, Z. B., Allen, B. D., García, J., Jarvis, K., & Markl, M. (2014) · PubMed · doi:10.3978/j.issn.2223-3652.2014.01.02 · Cited by 281
Kim, W. Y., Walker, P. G., Pedersen, E. M., Poulsen, J. K., Oyre, S., Houlind, K., & Yoganathan, A. P. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00141-l · Cited by 274
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Gatehouse, P. D., Rolf, M. P., Graves, M. J., Hofman, M. B., Totman, J., Werner, B., Quest, R. A., Liu, Y., von Spiczak, J., Dieringer, M., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-5 · Cited by 234
“Phase contrast cardiovascular magnetic resonance (CMR) [1] measurements of flow through planes transecting the great arteries are used clinically for calculations of cardiac output, shunt flow [2,3] or aortic or pulmonary regurgitation [4,5].”
Self-citationCaprihan, A., & Fukushima, E. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90046-5 · Cited by 234
Edelman, R. R., & Warach, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281008 · Cited by 213
Estimation of 3-D left ventricular deformation from medical images using biomechanical models
Papademetris, X., Sinusas, A. J., Dione, D. P., Constable, R. T., & Duncan, J. S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801163 · Cited by 212
“While the basic ideas were first suggested by van Dijk [52] and Nayler [33], it was Pelc and his team [39]–[41] that first bridged the technique to conventional cine”
Flow Measurement by Magnetic Resonance: A Unique Asset Worth Optimising
Kilner, P. J., Gatehouse, P. D., & Firmin, D. N. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701465090 · Cited by 205
“Phase contrast CMR measurement of blood flow has been available for over 20 years (1), and there have been publications reporting its use in a range of clinical applications.”
BackgroundSelf-citationCardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
“Gradient-echo sequences can also be used to measure blood flow velocity using a technique known as phase contrast velocity mapping [31-34].”
MethodSelf-citationMotion in Cardiovascular MR Imaging
Scott, A. D., Keegan, J., & Firmin, D. N. (2009) · Radiology · doi:10.1148/radiol.2502071998 · Cited by 175
Self-citationHemodynamics in the carotid artery bifurcation:
Botnar, R., Rappitsch, G., Beat Scheidegger, M., Liepsch, D., Perktold, K., & Boesiger, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00164-5 · Cited by 169
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22199 · Cited by 166
“While most clinical applications of MRA rely on the application of Gadolinium (Gd) contrast agent (CA), three-dimensional (3D) phase contrast (PC)-MRA based on velocity-encoded 3D MRI with encoding in three directions has proven to be a useful alternative (8-11).”
Background
Metadata
- Authors
- Nayler, G. L., Firmin, D. N., & Longmore, D. B.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1986-09
- Volume
- 10
- Issue
- 5
- Pages
- 715-722
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2008281673
- Cited by
- 634
- References
- 0
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.