CoChat

Motion Artifact Suppression Technique (MAST) for MR Imaging

Pattany, Pradip M., Phillips, Jeffrey J., Chiu, Lee C., Lipcamon, James D., Duerk, Jeffrey L., McNally, James M., Mohapatra, Surya N. · 1987 · Journal of Computer Assisted Tomography
Cited by 217

The DOI matches its Crossref record.

Abstract

A technique has been developed that significantly improves the image resolution and reduces motion artifacts in conventional two-dimensional Fourier transform and three-dimensional Fourier transform magnetic resonance imaging sequences. Modifications on the gradient waveforms completely refocus the transverse magnetization at the echo time, regardless of the motion occurring between the time of the 90 degrees radiofrequency excitation and the echo time (within-view). This accomplishes suppression of motion artifacts and regains the signal from flowing blood and CSF. Images of the head, abdomen, chest, and spine are reproduced which show the increase in signal and anatomical detail that would otherwise be degraded and lost in artifact noise. This technique has reduced the practical difficulty of obtaining clinically diagnostic T2-weighted abdominal images. It also has allowed diagnostic quality T1- and T2-weighted images to be obtained with one acquisition per view, thus reducing the total scan time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198705000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N.
Venue
Journal of Computer Assisted Tomography
Published
1987-05
Volume
11
Issue
3
Pages
369-377
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2016838404
Cited by
217
References
0
FWCI
22.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.