NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
Abstract
The variation with field strength or interecho interval of the T1 and T2 relaxation times of oxyhemoglobin (HbO2), deoxyhemoglobin (Hb), and methemoglobin (MHb) in either intact or lysed red blood cells was studied with a variable field (0.19–1.4 T) nuclear magnetic resonance spectroscopy unit. The T2 relaxation time of intracellular HbO2 decreased slightly with increasing field strength and interecho interval. The T2 relaxation times of intracellular Hb and MHb decreased markedly with increasing field strength and interecho interval. This T2 proton relaxation enhancement increased as the square of the applied field strength and was 1.6 times stronger for intracellular MHb than for intracellular Hb. The T2 relaxation enhancement is secondary to the loss of transverse phase coherence of water protons that diffuse across cellular magnetic field gradients. These field gradients occur when an external field is applied to a region with gradients of magnetic susceptibility. The heterogeneity of magnetic susceptibility is caused by the heterogeneous distribution (only intracellular) of the paramagnetic molecules (Hb or MHb). The T2 relaxation times of red cell lysates (homogeneous magnetic susceptibility) were independent of field strength or interecho interval. There was a decrease in the T1 relaxation times when the red cells were lysed. This may be due to an increase in the slow motional components of water molecules, because of the decrease in the average distance between water and hemoglobin molecules in the lysate. The Tl relaxation times of all the MHb samples were shortened because of proton-electron dipolar-dipolar relaxation enhancement. All the Tl relaxation times increased with increasing field strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
van Zijl, P. C. M., Eleff, S. M., Ulatowski, J. A., Oja, J. M. E., Uluǧ, A. M., Traystman, R. J., & Kauppinen, R. A. (1998) · Nature Medicine · doi:10.1038/nm0298-159 · Cited by 501
Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1072 · Cited by 461
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Clinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Metadata
- Authors
- Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-07
- Volume
- 11
- Issue
- 4
- Pages
- 684-690
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W4293245246
- Cited by
- 195
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity. https://app.cochat.ai/papers/10.1097/00004728-198707000-00025
- The paper
- Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987). NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198707000-00025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.