NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
The DOI matches its Crossref record.
Abstract
The variation with field strength or interecho interval of the T1 and T2 relaxation times of oxyhemoglobin (HbO2), deoxyhemoglobin (Hb), and methemoglobin (MHb) in either intact or lysed red blood cells was studied with a variable field (0.19–1.4 T) nuclear magnetic resonance spectroscopy unit. The T2 relaxation time of intracellular HbO2 decreased slightly with increasing field strength and interecho interval. The T2 relaxation times of intracellular Hb and MHb decreased markedly with increasing field strength and interecho interval. This T2 proton relaxation enhancement increased as the square of the applied field strength and was 1.6 times stronger for intracellular MHb than for intracellular Hb. The T2 relaxation enhancement is secondary to the loss of transverse phase coherence of water protons that diffuse across cellular magnetic field gradients. These field gradients occur when an external field is applied to a region with gradients of magnetic susceptibility. The heterogeneity of magnetic susceptibility is caused by the heterogeneous distribution (only intracellular) of the paramagnetic molecules (Hb or MHb). The T2 relaxation times of red cell lysates (homogeneous magnetic susceptibility) were independent of field strength or interecho interval. There was a decrease in the T1 relaxation times when the red cells were lysed. This may be due to an increase in the slow motional components of water molecules, because of the decrease in the average distance between water and hemoglobin molecules in the lysate. The Tl relaxation times of all the MHb samples were shortened because of proton-electron dipolar-dipolar relaxation enhancement. All the Tl relaxation times increased with increasing field strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
van Zijl, P. C. M., Eleff, S. M., Ulatowski, J. A., Oja, J. M. E., Uluǧ, A. M., Traystman, R. J., & Kauppinen, R. A. (1998) · Nature Medicine · doi:10.1038/nm0298-159 · Cited by 501
Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1072 · Cited by 461
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Clinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
Bandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070104 · Cited by 349
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Twenty years of functional MRI: The science and the stories
Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.026 · Cited by 265
Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 Tesla
Silvennoinen, M. J., Clingman, C. S., Golay, X., Kauppinen, R. A., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10355 · Cited by 219
Sehgal, V., Delproposto, Z., Haddar, D., Haacke, E. M., Sloan, A. E., Zamorano, L. J., Barger, G., Hu, J., Xu, Y., Prabhakaran, K. P., et al. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20598 · Cited by 204
“While the apparent edema signal is not as high as in a true FLAIR sequence, the combination of T2* and edema effects within a single image improves lesion detection even without a contrast agent.”
BackgroundInfluentialClinical applications of susceptibility weighted MR imaging of the brain – a pictorial review
Thomas, B., Somasundaram, S., Thamburaj, K., Kesavadas, C., Gupta, A. K., Bodhey, N. K., & Kapilamoorthy, T. R. (2008) · Neuroradiology · doi:10.1007/s00234-007-0316-z · Cited by 180
“Deoxyhemoglobin causes a reduction in T2* as well as a phase difference between the vessel and its surrounding parenchyma [12–14].”
BackgroundField dependent transverse relaxation rate increase may be a specific measure of tissue iron stores
Bartzokis, G., Aravagiri, M., Oldendorf, W. H., Mintz, J., & Marder, S. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290406 · Cited by 172
Hammond, K. E., Lupo, J. M., Xu, D., Metcalf, M., Kelley, D. A. C., Pelletier, D., Chang, S. M., Mukherjee, P., Vigneron, D. B., & Nelson, S. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.037 · Cited by 166
“It has been reported that the high paramagnetic susceptibility of clotted hematoma initially drops as the red blood cells are destroyed (Gomori et al., 1987) and later returns when ferritin and hemosiderin are formed (Sehgal et al.”
InfluentialPedersen, M., Dissing, T. H., Merkenborg, J., Stedkilde-Jergensen, H., Hansen, L. H., Pedersen, L. B., Grenier, N., & Frekiaer, J. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.00334.x · Cited by 166
“This technique is based on diamagnetic properties of oxyhemoglobin whereas deoxyhemoglobin has paramagnetic properties in a magnetic fiel”
MethodNMR relaxation in tissues with weak magnetic inhomogeneities
Jensen, J. H., & Chandra, R. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<144::aid-mrm21>3.0.co;2-o · Cited by 153
Iron imaging reveals tumor and metastasis macrophage hemosiderin deposits in breast cancer
Leftin, A., Ben-Chetrit, N., Klemm, F., Joyce, J. A., & Koutcher, J. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184765 · Cited by 36
Leftin, A., Zhao, H., Turkekul, M., de Stanchina, E., Manova, K., & Koutcher, J. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-11899-2 · Cited by 33
Metadata
- Authors
- Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1987-07
- Volume
- 11
- Issue
- 4
- Pages
- 684-690
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W4293245246
- Cited by
- 195
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.