Efficient method for calculating kinetic parameters using T1‐weighted dynamic contrast‐enhanced magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
It has become increasingly important to quantitatively estimate tissue physiological parameters such as perfusion, capillary permeability, and the volume of extravascular‐extracellular space (EES) using T1‐weighted dynamic contrast‐enhanced MRI (DCE‐MRI). A linear equation was derived by integrating the differential equation describing the kinetic behavior of contrast agent (CA) in tissue, from which K1 (rate constant for the transfer of CA from plasma to EES), k2 (rate constant for the transfer from EES to plasma), and Vp (plasma volume) can be easily obtained by the linear least‐squares (LLSQ) method. The usefulness of this method was investigated by means of computer simulations, in comparison with the nonlinear least‐squares (NLSQ) method. The new method calculated the above parameters faster than the NLSQ method by a factor of approximately 6, and estimated them more accurately than the NLSQ method at a signal‐to‐noise ratio (SNR) of < ∼10. This method will be useful for generating functional images of K1, k2, and Vp from DCE‐MRI data. Magn Reson Med 51:858–862, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659 · cited 1×
“[5] can be easily solved for the elements of B using the conventional linear least-squares (LLSQ) method, and finally K1, k2, and Vp can be easily obtained from the elements.”
MethodFunctional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439 · cited 2×
“[2] with the assumption that the initial conditions are zero yields”
BackgroundLarsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431 · cited 1×
“Equation [4] can be given in a matrix form as”
BackgroundCerebral [ 15 O]Water Clearance in Humans Determined by PET: I. Theory and Normal Values
Ohta, S., Meyer, E., Fujita, H., Reutens, D. C., Evans, A. C., & GJEDDE, A. H. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00002 · Cited by 154
Cited by
Pang, Y., Turkbey, B., Bernardo, M., Kruecker, J., Kadoury, S., Merino, M. J., Wood, B. J., Pinto, P. A., & Choyke, P. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24277 · Cited by 189
Benou, A., Veksler, R., Friedman, A., & Riklin Raviv, T. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.006 · Cited by 91
Metadata
- Authors
- Murase, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-03-26
- Volume
- 51
- Issue
- 4
- Pages
- 858-862
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2066037527
- Cited by
- 170
- References
- 8
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient method for calculating kinetic parameters using T1‐weighted dynamic contrast‐enhanced magnetic resonance imaging. https://app.cochat.ai/papers/10.1002/mrm.20022
- The paper
- Murase, K. (2004). Efficient method for calculating kinetic parameters using T1‐weighted dynamic contrast‐enhanced magnetic resonance imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.