Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Powell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Self-citationAccurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Self-citationA technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Self-citationAutomated 3-D registration of MR and CT images of the head
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80011-9 · Cited by 374
Self-citationComparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationEvaluation of ridge seeking operators for multimodality medical image matching
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.491617 · Cited by 189
Self-citationNew approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Self-citationVoxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Self-citation
Cited by
Items 101–116 of 116
Maurer, C. R., Maciunas, R. J., & Fitzpatrick, J. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736031 · Cited by 163
Self-citationIntroduction to the Non-rigid Image Registration Evaluation Project (NIREP)
Christensen, G. E., Geng, X., Kuhl, J. G., Bruss, J., Grabowski, T. J., Pirwani, I. A., Vannier, M. W., Allen, J. S., & Damasio, H. (2006) · Lecture Notes in Computer Science · doi:10.1007/11784012_16 · Cited by 161
“The Nonrigid Image Registration Evaluation Project (NIREP) will build upon these earlier projects and provide a rich set of metrics for evaluating registration performance.”
BackgroundInfluentialMedical image registration with partial data
Periaswamy, S., & Farid, H. (2006) · Medical Image Analysis · doi:10.1016/j.media.2005.03.006 · Cited by 159
Tsao, J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815077 · Cited by 158
“In recent years, MI has become the match metric of choice due to its wide applicability and overall accuracy [19].”
BackgroundRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Self-citationMicroglial activation in healthy aging
Schuitemaker, A., van der Doef, T. F., Boellaard, R., van der Flier, W. M., Yaqub, M., Windhorst, A. D., Barkhof, F., Jonker, C., Kloet, R. W., Lammertsma, A. A., et al. (2012) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.09.016 · Cited by 142
Amphetamine-induced displacement of [18F] fallypride in striatum and extrastriatal regions in humans
Riccardi, P., Li, R., Ansari, M. S., Zald, D., Park, S., Dawant, B., Anderson, S., Doop, M., Woodward, N., Schoenberg, E., et al. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300916 · Cited by 134
Self-citationCAI4CAI: The Rise of Contextual Artificial Intelligence in Computer Assisted Interventions
Vercauteren, T., Unberath, M., Padoy, N., & Navab, N. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2946993 · Cited by 125
“Because of the seminal work of the Retrospective Registration Evaluation Project (RREP) [7], it is also clear that preoperative rigid registration of different imaging modalities, such as MR and CT, provides a robust means of fusing soft tissue contrast information with accurate bone delineation for neurosurgical plan…”
BackgroundZollei, L., Grimson, E., Norbash, A., & Wells, W. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.991032 · Cited by 120
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Nakamoto, Y., Chin, B. B., Kraitchman, D. L., Lawler, L. P., Marshall, L. T., & Wahl, R. L. (2003) · Radiology · doi:10.1148/radiol.2273020299 · Cited by 111
Klumpers, U. M. H., Veltman, D. J., Drent, M. L., Boellaard, R., Comans, E. F. I., Meynen, G., Lammertsma, A. A., & Hoogendijk, W. J. G. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1292-9 · Cited by 95
“MRI scans were coregistered with summed [C]FMZ images (10–60 min after injection) [38, 39].”
MethodMulti-modal image registration based on gradient orientations of minimal uncertainty
De Nigris, D., Collins, D. L., & Arbel, T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2218116 · Cited by 73
Multi-Modal Medical Image Registration with Full or Partial Data: A Manifold Learning Approach
Bashiri, F. S., Baghaie, A., Rostami, R., Yu, Z., & D’Souza, R. M. (2018) · Journal of Imaging · doi:10.3390/jimaging5010005 · Cited by 46
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
Self-citationSo, R. W. K., & Chung, A. C. S. (2017) · Pattern Recognition · doi:10.1016/j.patcog.2016.09.004 · Cited by 36
“The rigid registration experiments including six sets of clinical brain X-ray Computed Tomography (CT) and T1-weighted magnetic resonance (T1) image pairs from the Retrospective Image Registration Evaluation (RIRE) project [20].”
MethodInfluentialThe truth is hard to make: Validation of medical image registration
Pluim, J. P. W., Muenzing, S. E. A., Eppenhof, K. A. J., & Murphy, K. (2016) · 2016 23rd International Conference on Pattern Recognition (ICPR) · doi:10.1109/icpr.2016.7899978 · Cited by 34
“The Retrospective Registration Evaluation Project by Vanderbilt University challenged researchers to rigidly register multimodal brain images [22].”
Background
Metadata
- Authors
- West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., Maes, F., Suetens, P., Vandermeulen, D., van den Elsen, P. A., Napel, S., Sumanaweera, T. S., Harkness, B., Hemler, P. F., Hill, D. L. G., Hawkes, D. J., Studholme, C., Maintz, J. B. A., Viergever, M. A., Malandain, G., Pennec, X., Noz, M. E., Maguire, G. Q., Pollack, M., Pelizzari, C. A., Robb, R. A., Hanson, D., & Woods, R. P.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1997-07
- Volume
- 21
- Issue
- 4
- Pages
- 554-568
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2134165173
- Cited by
- 884
- References
- 14
- FWCI
- 49.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.