Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Powell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Self-citationAccurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Self-citationA technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Self-citationAutomated 3-D registration of MR and CT images of the head
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80011-9 · Cited by 374
Self-citationComparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationEvaluation of ridge seeking operators for multimodality medical image matching
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.491617 · Cited by 189
Self-citationNew approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Self-citationVoxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Self-citation
Cited by
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
“A lot of work has been done on validation of rigid-body registration (the most comprehensive case-study is probably the Vanderbilt University project [207]) while validation of non-linear, local and elastic registration methods is still at the beginning.”
BackgroundMethodNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
“An alternative voxel-based similarity measure is mutual information (MI), which has been independently proposed by Collignon [10] and Viola [11], and which has been shown to align images from different modalities accurately and robustly [29].”
MethodSelf-citationMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
“tration evaluation” (RIRE) project [27], which has ground truth correspondences for the 8 corner points of the images.”
BackgroundSelf-citationMedical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Self-citationAn overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationHill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citationAutomated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Self-citationHighly accurate inverse consistent registration: A robust approach
Reuter, M., Rosas, H. D., & Fischl, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.020 · Cited by 1,388
Survey: interpolation methods in medical image processing
Lehmann, T. M., Gonner, C., & Spitzer, K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816070 · Cited by 1,340
Spatial Normalization of Brain Images with Focal Lesions Using Cost Function Masking
Brett, M., Leff, A. P., Rorden, C., & Ashburner, J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0845 · Cited by 1,025
Multimodal Image Coregistration and Partitioning—A Unified Framework
Ashburner, J., & Friston, K. (1997) · NeuroImage · doi:10.1006/nimg.1997.0290 · Cited by 927
PET-CT image registration in the chest using free-form deformations
Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809072 · Cited by 871
Multi-modality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534053 · Cited by 795
Self-citationA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Amphetamine-induced dopamine release in human ventral striatum correlates with euphoria
Drevets, W. C., Gautier, C., Price, J. C., Kupfer, D. J., Kinahan, P. E., Grace, A. A., Price, J. L., & Mathis, C. A. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01038-6 · Cited by 706
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Self-citationImage registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
Self-citationSynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retraining
Billot, B., Greve, D. N., Puonti, O., Thielscher, A., Van Leemput, K., Fischl, B., Dalca, A. V., & Iglesias, J. E. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102789 · Cited by 641
Heller, N., Isensee, F., Maier-Hein, K. H., Hou, X., Xie, C., Li, F., Nan, Y., Mu, G., Lin, Z., Han, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101821 · Cited by 579
The correlation ratio as a new similarity measure for multimodal image registration
Roche, A., Malandain, G., Pennec, X., & Ayache, N. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056301 · Cited by 542
Self-citationCardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Serial Intraoperative Magnetic Resonance Imaging of Brain Shift
Nabavi, A., Black, P. M., Gering, D. T., Westin, C.-F., Mehta, V., Pergolizzi, R. S., Ferrant, M., Warfield, S. K., Hata, N., Schwartz, R. B., et al. (2001) · Neurosurgery · doi:10.1097/00006123-200104000-00019 · Cited by 461
The distribution of target registration error in rigid-body point-based registration
Fitzpatrick, J. M., & West, J. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952729 · Cited by 457
Self-citationRohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
Self-citationEvaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
Self-citationMedical image registration using mutual information
Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817864 · Cited by 432
Self-citationRohlfing, T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2163944 · Cited by 412
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00066 · Cited by 404
Self-citationMaes, F., Vandermeulen, D., & Suetens, P. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80030-9 · Cited by 397
Self-citationAdaptive Stochastic Gradient Descent Optimisation for Image Registration
Klein, S., Pluim, J. P. W., Staring, M., & Viergever, M. A. (2009) · International Journal of Computer Vision · doi:10.1007/s11263-008-0168-y · Cited by 387
Self-citationSvarer, C., Madsen, K., Hasselbalch, S. G., Pinborg, L. H., Haugbøl, S., Frøkjær, V. G., Holm, S., Paulson, O. B., & Knudsen, G. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.017 · Cited by 386
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Why rankings of biomedical image analysis competitions should be interpreted with care
Maier-Hein, L., Eisenmann, M., Reinke, A., Onogur, S., Stankovic, M., Scholz, P., Arbel, T., Bogunovic, H., Bradley, A. P., Carass, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07619-7 · Cited by 380
Global image registration using a symmetric block-matching approach
Modat, M., Cash, D. M., Daga, P., Winston, G. P., Duncan, J. S., & Ourselin, S. (2014) · Journal of Medical Imaging · doi:10.1117/1.jmi.1.2.024003 · Cited by 374
Rohlfing, T., & Maurer, C. R. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.808506 · Cited by 373
Self-citationGering, D. T., Nabavi, A., Kikinis, R., Hata, N., O'Donnell, L. J., Grimson, W. E. L., Jolesz, F. A., Black, P. M., & Wells, W. M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1139 · Cited by 366
Schaap, M., Metz, C. T., van Walsum, T., van der Giessen, A. G., Weustink, A. C., Mollet, N. R., Bauer, C., Bogunović, H., Castro, C., Deng, X., et al. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.06.003 · Cited by 362
A review of cardiac image registration methods
Makela, T., Clarysse, P., Sipila, O., Pauna, N., Pham, Q. C., Katila, T., & Magnin, I. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804441 · Cited by 361
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
A survey of medical image registration – under review
Viergever, M. A., Maintz, J. B. A., Klein, S., Murphy, K., Staring, M., & Pluim, J. P. W. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.030 · Cited by 318
Self-citationMotion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Dual-Modality Imaging: Combining Anatomy and Function
Townsend, D. W. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051276 · Cited by 282
Block Matching: A General Framework to Improve Robustness of Rigid Registration of Medical Images
Ourselin, S., Roche, A., Prima, S., & Ayache, N. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_57 · Cited by 279
A viscous fluid model for multimodal non-rigid image registration using mutual information
D'Agostino, E., Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00039-2 · Cited by 277
Self-citationBrain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Mukherjee, J., Christian, B. T., Dunigan, K. A., Shi, B., Narayanan, T. K., Satter, M., & Mantil, J. (2002) · Synapse · doi:10.1002/syn.10128 · Cited by 270
Deep learning based synthesis of MRI, CT and PET: Review and analysis
Dayarathna, S., Islam, K. T., Uribe, S., Yang, G., Hayat, M., & Chen, Z. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103046 · Cited by 265
Medical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationNonrigid Image Registration Using Conditional Mutual Information
Loeckx, D., Slagmolen, P., Maes, F., Vandermeulen, D., & Suetens, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021843 · Cited by 257
Self-citationInterpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Self-citationSchnabel, J. A., Tanner, C., Castellano-Smith, A. D., Degenhard, A., Leach, M. O., Hose, D. R., Hill, D. L. G., & Hawkes, D. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808367 · Cited by 255
Self-citationHering, A., Hansen, L., Mok, T. C. W., Chung, A. C. S., Siebert, H., Hager, S., Lange, A., Kuckertz, S., Heldmann, S., Shao, W., et al. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3213983 · Cited by 250
“Starting from RIRE [10], which compared rigid-body alignment of head MR (T1, T2), PET and CT, there have been several brain registration benchmarks - most notably the evaluation of 14 nonlinear iterative registration algorithms [11].”
MethodHarris, G., Andreasen, N. C., Cizadlo, T., Bailey, J. M., Bockholt, H. J., Magnotta, V. A., & Arndt, S. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199901000-00030 · Cited by 243
Unifying maximum likelihood approaches in medical image registration
Roche, A., Malandain, G., & Ayache, N. (2000) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(2000)11:1<71::aid-ima8>3.0.co;2-5 · Cited by 223
Self-citationReview and current status of SPECT scatter correction
Hutton, B. F., Buvat, I., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/r01 · Cited by 217
“Similar exercises have proven to be very effective in demonstrating optimal choice of registration algorithms (West et al 1997).”
BackgroundDawant, B. M., Hartmann, S. L., Thirion, J.-P., Maes, F., Vandermeulen, D., & Demaerel, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811271 · Cited by 217
Self-citationSwennen, G. R. J., Mollemans, W., De Clercq, C., Abeloos, J., Lamoral, P., Lippens, F., Neyt, N., Casselman, J., & Schutyser, F. (2009) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e3181996803 · Cited by 216
Image-to-patient registration techniques in head surgery
Eggers, G., Mühling, J., & Marmulla, R. (2006) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2006.09.015 · Cited by 214
Debois, M., Oyen, R., Maes, F., Verswijvel, G., Gatti, G., Bosmans, H., Feron, M., Bellon, E., Kutcher, G., Van Poppel, H., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00288-6 · Cited by 212
Self-citationStandardized evaluation methodology for 2-D-3-D registration
van de Kraats, E. B., Penney, G. P., Tomazevic, D., van Walsum, T., & Niessen, W. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.853240 · Cited by 211
“Previous investigation shows that errors in multi-modality 3-D–3-D registration can be in the order of the voxel size of the images [33].”
BackgroundAtlas-Based Segmentation of Pathological MR Brain Images Using a Model of Lesion Growth
BachCuadra, M., Pollo, C., Bardera, A., Cuisenaire, O., Villemure, J.-G., & Thiran, J.-P. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.834618 · Cited by 209
“The validation of registration between healthy subjects is a very active research area [16]–[18].”
BackgroundLoubele, M., Van Assche, N., Carpentier, K., Maes, F., Jacobs, R., van Steenberghe, D., & Suetens, P. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2007.05.004 · Cited by 208
Self-citationPositron Emission Tomography/Computed Tomography
Townsend, D. W. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.003 · Cited by 206
Retrospective evaluation of intersubject brain registration
Hellier, P., Barillot, C., Corouge, I., Gibaud, B., Le Goualher, G., Collins, D. L., Evans, A., Malandain, G., Ayache, N., Christensen, G. E., et al. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816961 · Cited by 200
“This evaluation project was inspired by the Vanderbilt evaluation project [45], [46] in which all participants downloaded the data and performed the registration processes in their laboratory without knowing the evaluation criteria.”
BackgroundMethodSelf-citationThe role of image registration in brain mapping
Toga, A. W., & Thompson, P. M. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00055-x · Cited by 198
“Meanwhile, automated methods were rapidly being developed to register new MRI and PET data into a common space (see [36] [37], for a comparative study and a review).”
MethodReduced GABAA benzodiazepine receptor binding in veterans with post-traumatic stress disorder
Geuze, E., van Berckel, B. N. M., Lammertsma, A. A., Boellaard, R., de Kloet, C. S., Vermetten, E., & Westenberg, H. G. M. (2008) · Molecular Psychiatry · doi:10.1038/sj.mp.4002054 · Cited by 198
Changes in the normal appearing brain tissue and cognitive impairment in multiple sclerosis
Filippi, M. (2000) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.68.2.157 · Cited by 195
Maurer, C. R., Hill, D. L. G., Martin, A. J., Liu, H., McCue, M., Rueckert, D., Lloret, D., Hall, W. A., Maxwell, R. E., Hawkes, D. J., et al. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736050 · Cited by 195
Self-citationWeltens, C., Menten, J., Feron, M., Bellon, E., Demaerel, P., Maes, F., Van den Bogaert, W., & van der Schueren, E. (2001) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00371-1 · Cited by 187
Self-citationZen and the art of medical image registration: correspondence, homology, and quality
Crum, W. R., Griffin, L. D., Hill, D. L. G., & Hawkes, D. J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.014 · Cited by 186
“Furthermore, we suggest that in the present climate, clinical studies whose results rely heavily on registration techniques of questionable validity should be treated with suspicion.”
BackgroundSelf-citationLaser Surface Scanning for Patient Registration in Intracranial Image-guided Surgery
Raabe, A., Krishnan, R., Wolff, R., Hermann, E., Zimmermann, M., & Seifert, V. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00021 · Cited by 185
Mapping of functional organization in human visual cortex: Electrical cortical stimulation
Lee, H. W., Hong, S. B., Seo, D. W., Tae, W. S., & Hong, S. C. (2000) · Neurology · doi:10.1212/wnl.54.4.849 · Cited by 184
Atrophy rates of entorhinal cortex in AD and normal aging
Du, A. T., Schuff, N., Zhu, X. P., Jagust, W. J., Miller, B. L., Reed, B. R., Kramer, J. H., Mungas, D., Yaffe, K., Chui, H. C., et al. (2003) · Neurology · doi:10.1212/01.wnl.0000044400.11317.ec · Cited by 184
Quo Vadis, Atlas-Based Segmentation?
Rohlfing, T., Brandt, R., Menzel, R., Russakoff, D. B., & Maurer, C. R. (2005) · Handbook of Biomedical Image Analysis · doi:10.1007/0-306-48608-3_11 · Cited by 183
“[76] has been found to produce highly accurate (rigid) transformation in an independent, blinded evaluation study [88].”
MethodSelf-citationComparison of fMRI motion correction software tools
Oakes, T. R., Johnstone, T., Ores Walsh, K. S., Greischar, L. L., Alexander, A. L., Fox, A. S., & Davidson, R. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.058 · Cited by 182
A magnetization transfer histogram study of normal-appearing brain tissue in MS
Tortorella, C., Viti, B., Bozzali, M., Sormani, M. P., Rizzo, G., Gilardi, M. F., Comi, G., & Filippi, M. (2000) · Neurology · doi:10.1212/wnl.54.1.186 · Cited by 181
Registration of stereo and temporal images of the retina
Ritter, N., Owens, R., Cooper, J., Eikelboom, R. H., & Van Saarloos, P. P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774168 · Cited by 181
Validation of medical image processing in image-guided therapy
Jannin, P., Fitzpatrick, J. M., Hawkes, D. J., Pennec, X., Shahidl, R., & Vannier, M. W. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806568 · Cited by 177
Self-citation3D/2D registration and segmentation of scoliotic vertebrae using statistical models
Benameur, S., Mignotte, M., Parent, S., Labelle, H., Skalli, W., & de Guise, J. (2003) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(03)00019-3 · Cited by 175
Evaluation of Six Registration Methods for the Human Abdomen on Clinically Acquired CT
Xu, Z., Lee, C. P., Heinrich, M. P., Modat, M., Rueckert, D., Ourselin, S., Abramson, R. G., & Landman, B. A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2574816 · Cited by 175
Fast and robust registration of PET and MR images of human brain
Čı́žek, J., Herholz, K., Vollmar, S., Schrader, R., Klein, J., & Heiss, W.-D. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.01.016 · Cited by 172
Microglial activation in Alzheimer's disease: an (R)-[11C]PK11195 positron emission tomography study
Schuitemaker, A., Kropholler, M. A., Boellaard, R., van der Flier, W. M., Kloet, R. W., van der Doef, T. F., Knol, D. L., Windhorst, A. D., Luurtsema, G., Barkhof, F., et al. (2013) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2012.04.021 · Cited by 171
“For each subject, PET and MRI scans were coregistered using the software package MIRIT (Maes et al., 1997; West et al., 1997).”
MethodOu, Y., Akbari, H., Bilello, M., Da, X., & Davatzikos, C. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2330355 · Cited by 171
“, [10]), for skull-stripped images only (e.”
InfluentialImage Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00010 · Cited by 170
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
“It has been clear for some time that intensity-based cost functions outperform landmark and fiducial-marker-based approaches [35], [36].”
BackgroundStudies of Neuroplasticity With Transcranial Magnetic Stimulation
Cohen, L. G., Ziemann, U., Chen, R., Classen, J., Hallett, M., Gerloff, C., & Butefisch, C. (1998) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199807000-00003 · Cited by 169
Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study
Loubele, M., Maes, F., Schutyser, F., Marchal, G., Jacobs, R., & Suetens, P. (2006) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2005.10.039 · Cited by 168
Self-citation3-D/2-D registration of CT and MR to X-ray images
Tomazevic, D., Likar, B., Slivnik, T., & Pernus, F. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819277 · Cited by 167
“The rotation error was determined by decomposing TRE to translation and rotation components [28].”
MethodAccurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
Studholme, C., Constable, R. T., & Duncan, J. S. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896788 · Cited by 167
Self-citationOnline resource for validation of brain segmentation methods
Shattuck, D. W., Prasad, G., Mirza, M., Narr, K. L., & Toga, A. W. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.066 · Cited by 166
Chen, H.-M., & Varshney, P. K. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816949 · Cited by 165
A STUDY OF THE ACCURACY OF CYBERKNIFE SPINAL RADIOSURGERY USING SKELETAL STRUCTURE TRACKING
Ho, A. K., Fu, D., Cotrutz, C., Hancock, S. L., Chang, S. D., Gibbs, I. C., Maurer, C. R., & Adler, J. R. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000249248.55923.ec · Cited by 163
Self-citation
Metadata
- Authors
- West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., Maes, F., Suetens, P., Vandermeulen, D., van den Elsen, P. A., Napel, S., Sumanaweera, T. S., Harkness, B., Hemler, P. F., Hill, D. L. G., Hawkes, D. J., Studholme, C., Maintz, J. B. A., Viergever, M. A., Malandain, G., Pennec, X., Noz, M. E., Maguire, G. Q., Pollack, M., Pelizzari, C. A., Robb, R. A., Hanson, D., & Woods, R. P.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1997-07
- Volume
- 21
- Issue
- 4
- Pages
- 554-568
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2134165173
- Cited by
- 884
- References
- 14
- FWCI
- 49.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.