Assessment of Vertebral Bone Mineral Density Using Volumetric Quantitative CT
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this work was to determine the precision and diagnostic efficacy of bone mineral density (BMD) measures based on volumetric quantitative CT (QCT) of the spine. METHOD: Volumetric CT scans of L1 and L2 (GE-9800Q; 80 kVp, 140 mAs, 3 mm slices) were acquired in a cohort of 62 osteoporotic women (mean age 70.4 years, T(DXA hip or spine) < -2.5), of whom 20 had vertebral fractures and 42 were nonfractured control subjects. An image analysis technique delineated trabecular, cortical, and integral regions in reference to a vertebra-fixed coordinate system. We computed precision values and fracture control differences for these new regions and for single-slice QCT and dual X-ray absorptiometry (DXA) measures synthesized from the volumetric data. RESULTS: Volumetric trabecular BMD showed higher precision (1.3%) than the synthesized single-slice measures (2.1-2.8%). Volumetric and single-slice trabecular BMD showed equivalent decrements between fractured and nonfractured subjects (17-19%), with integral BMD showing smaller and less significant differences (7-8%). CONCLUSION: Volumetric and single-slice QCT techniques are equivalent for vertebral fracture risk estimation, but volumetric techniques should be superior for monitoring therapy efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vertebral fracture assessment using a semiquantitative technique
Genant, H. K., Wu, C. Y., van Kuijk, C., & Nevitt, M. C. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080915 · Cited by 3,691
Self-citationGlüer, C. C., Blake, G., Lu, Y., Blunt1, B. A., Jergas1, M., & Genant1, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282
Self-citationNew approaches for interpreting projected bone densitometry data
Professor Carter, D. R., Bouxsein, M. L., & Marcus, R. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070204 · Cited by 1,065
Precise Measurement of Vertebral Mineral Content Using Computed Tomography
Cann, C. E., & Genant, H. K. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198008000-00018 · Cited by 540
Self-citationGrampp, S., Genant, H. K., Mathur, A., Lang, P., Jergas, M., Takada, M., Glüer, C.-C., Lu, Y., & Chavez, M. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.5.697 · Cited by 398
Self-citationQuantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
Self-citationLang, T. F., Keyak, J. H., Heitz, M. W., Augat, P., Lu, Y., Mathur, A., & Genant, H. K. (1997) · Bone · doi:10.1016/s8756-3282(97)00072-0 · Cited by 270
Self-citationEffective dose values in bone mineral measurements by photon absorptiometry and computed tomography
Kalender, W. A. (1992) · Osteoporosis International · doi:10.1007/bf01623841 · Cited by 210
Evaluation of cortical bone by computed tomography
Hangartner, T. N., & Gilsanz, V. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650111019 · Cited by 209
Vertebral bone mineral analysis: an integrated approach with CT.
Kalender, W. A., Klotz, E., & Suess, C. (1987) · Radiology · doi:10.1148/radiology.164.2.3602380 · Cited by 204
Cited by
Black, D. M., Greenspan, S. L., Ensrud, K. E., Palermo, L., McGowan, J. A., Lang, T. F., Garnero, P., Bouxsein, M. L., Bilezikian, J. P., & Rosen, C. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031975 · Cited by 1,174
Self-citationRiggs, B. L., Melton, L. J., Robb, R. A., Camp, J. J., Atkinson, E. J., Peterson, J. M., Rouleau, P. A., McCollough, C. H., Bouxsein, M. L., & Khosla, S. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040916 · Cited by 925
“Although skeletal QCT measurements have been available for almost 30 years, recent innovations in instrumentation and software have improved resolution and precision.((12,17)) Nonetheless, only a few large studies on skeletal changes with aging have been previously reported using QCT, and only two of them assessed cha…”
MethodCortical and Trabecular Bone Mineral Loss From the Spine and Hip in Long-Duration Spaceflight
Lang, T., LeBlanc, A., Evans, H., Lu, Y., Genant, H., & Yu, A. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040307 · Cited by 828
“CT images were transferred to a computer workstation and processed to extract measures of vBMD and bone size using analysis techniques described previously.((7,8)) The processing task included calibration of the CT images from the native scanner Hounsfield Units to equivalent concentration (g/cm(3)) of calcium hydroxy…”
MethodSelf-citationClinical Use of Bone Densitometry: Scientific Review
Cummings, S. R., Bates, D., & Black, D. M. (2002) · JAMA · doi:10.1001/jama.288.15.1889 · Cited by 817
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
One Year of Alendronate after One Year of Parathyroid Hormone (1–84) for Osteoporosis
Black, D. M., Bilezikian, J. P., Ensrud, K. E., Greenspan, S. L., Palermo, L., Hue, T., Lang, T. F., McGowan, J. A., & Rosen, C. J. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050336 · Cited by 614
Self-citationCrawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Quantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 453
Low Magnitude Mechanical Loading Is Osteogenic in Children With Disabling Conditions
Ward, K., Alsop, C., Caulton, J., Rubin, C., Adams, J., & Mughal, Z. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040129 · Cited by 432
Greenspan, S. L., Bone, H. G., Ettinger, M. P., Hanley, D. A., Lindsay, R., Zanchetta, J. R., Blosch, C. M., Mathisen, A. L., Morris, S. A., Marriott, T. B., et al. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-5-200703060-00005 · Cited by 427
Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
Yu, E. W., Thomas, B. J., Brown, J. K., & Finkelstein, J. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.506 · Cited by 300
“Moreover, with multislice helical acquisition, a newer CT technique for measuring BMD, the precision of QCT measurements is similar to that of DXA.((11,12)) Importantly, QCT can accurately distinguish soft tissue compartments while calculating bone density, and software corrections for beam-hardening theoretically min…”
ResultInfluentialBone quality: where do we go from here?
Bouxsein, M. L. (2003) · Osteoporosis International · doi:10.1007/s00198-003-1489-x · Cited by 264
Miller, P. D., Delmas, P. D., Lindsay, R., Watts, N. B., Luckey, M., Adachi, J., Saag, K., Greenspan, S. L., Seeman, E., Boonen, S., et al. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0353 · Cited by 222
Self-citationAdvanced CT bone imaging in osteoporosis
Genant, H. K., Engelke, K., & Prevrhal, S. (2008) · Rheumatology · doi:10.1093/rheumatology/ken180 · Cited by 196
Self-citationLiu, X. S., Cohen, A., Shane, E., Yin, P. T., Stein, E. M., Rogers, H., Kokolus, S. L., McMahon, D. J., Lappe, J. M., Recker, R. R., et al. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.111 · Cited by 186
“5-mm slice thickness, pitch1⁄4 1, standard reconstruction algorithm) were carried out at Columbia University/New York Presbyterian Hospital (GE CTi and GE Light Speed VCT 64, General Electric Medical Systems, Milwaukee, WI, USA) and Creighton University (Siemens Somatom Plus 4, Siemens Medical Systems, Iselin, NJ, USA…”
BackgroundMethodSelf-citation(2012) · Radiology · doi:10.1148/radiol.2633201203 · Cited by 173
Schafer, A. L., Weaver, C. M., Black, D. M., Wheeler, A. L., Chang, H., Szefc, G. V., Stewart, L., Rogers, S. J., Carter, J. T., Posselt, A. M., et al. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2467 · Cited by 172
“USA).((21,22)) Visceral adipose tissue area (cm(2)) was measured by CT using a single axial slice at the mid-L4 vertebra.”
MethodMastmeyer, A., Engelke, K., Fuchs, C., & Kalender, W. A. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.05.005 · Cited by 162
Metadata
- Authors
- Lang, T. F., Li, J., Harris, S. T., & Genant, H. K.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1999-01
- Volume
- 23
- Issue
- 1
- Pages
- 130-137
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1986290839
- Cited by
- 162
- References
- 19
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.