Usefulness of home blood pressure measurements in assessing the effect of treatment in a single-blind placebo-controlled open trial
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Reproducibility of home blood pressure measurements (HBP), and the placebo effect on HBP, were examined to establish the number of subjects required in order to observe a significant antihypertensive effect of a drug for a comparative study between placebo and active treatment. METHODS: Reproducibility of HBP (n = 172 for systolic blood pressure and n = 137 for diastolic blood pressure) and the placebo effect on HBP (n = 35 for systolic and n = 42 for diastolic blood pressure) were examined using a semi-automatic electronic device on untreated hypertensive subjects during 21 consecutive days of measurements. From these two studies, the number of subjects required in order to observe a significant antihypertensive drug effect was assessed. In both studies, measurements from the first 3 days were excluded from the analysis. RESULTS: Reproducibility, defined as the difference between the initial 5 day average (days 4-8) and the last 5 day average (days 17-21) was -1.9 +/- 7.0/-1.4 +/- 4.8 mmHg (mean +/- SD), indicating high reproducibility with a minimal regression to the mean effect. A placebo was administered after the 8 day run-in period. The difference between the initial 5 day average (days 4-8) and the last 5 day average (days 17-21) was compared. The mean difference was 1.1 +/- 6.2/0.2 +/- 5.7 mmHg, suggesting that there was a minimal, if any, placebo effect. As determined by the power calculations, based on the standard deviations of the tests for reproducibility and the placebo effect, nine of 13 subjects are required to show that a 9/5 mmHg decrease in systolic HBP/diastolic HBP (50% of estimated effective decrease in systolic HBP/diastolic HBP according to the guidelines for clinical trials in Japan) is statistically significant CONCLUSIONS: The results suggest that the HBP measurement is highly reproducible and that there is a minimal, if any, placebo effect. These characteristics of HBP contribute to minimizing the number of subjects necessary for assessment of antihypertensive drug effects in comparative studies between an active treatment and placebo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Feasibility Study of N-of-1 Trials With Blood Pressure Self-Monitoring in Hypertension
Chatellier, G., Day, M., Bobrie, G., & Menard, J. (1995) · Hypertension · doi:10.1161/01.hyp.25.2.294 · Cited by 72
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Self-citationO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Seppo, L., Jauhiainen, T., Poussa, T., & Korpela, R. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.2.326 · Cited by 666
Metadata
- Authors
- Imai, Y., Ohkubo, T., Hozawa, A., Tsuji, I., Matsubara, M., Araki, T., Chonan, K., Kikuya, M., Satoh, H., Hisamichi, S., & Nagai, K.
- Venue
- Journal of Hypertension
- Published
- 2001-02
- Volume
- 19
- Issue
- 2
- Pages
- 179-185
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2054275230
- Cited by
- 103
- References
- 3
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Usefulness of home blood pressure measurements in assessing the effect of treatment in a single-blind placebo-controlled open trial. https://app.cochat.ai/papers/10.1097/00004872-200102000-00003
- The paper
- Imai, Y., Ohkubo, T., Hozawa, A., Tsuji, I., Matsubara, M., Araki, T., Chonan, K., Kikuya, M., Satoh, H., Hisamichi, S., & Nagai, K. (2001). Usefulness of home blood pressure measurements in assessing the effect of treatment in a single-blind placebo-controlled open trial. Journal of Hypertension. https://doi.org/10.1097/00004872-200102000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.