Electronic compliance monitoring in resistant hypertension: the basis for rational therapeutic decisions
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hansson, L., Zanchetti, A., Carruthers, S. G., Dahlöf, B., Elmfeldt, D., Julius, S., Ménard, J., Rahn, K. H., Wedel, H., & Westerling, S. (1998) · The Lancet · doi:10.1016/s0140-6736(98)04311-6 · Cited by 5,728
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
(1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,695
Burt, V. L., Whelton, P., Roccella, E. J., Brown, C., Cutler, J. A., Higgins, M., Horan, M. J., & Labarthe, D. (1995) · Hypertension · doi:10.1161/01.hyp.25.3.305 · Cited by 2,998
How often is medication taken as prescribed? A novel assessment technique
Cramer, J. A. (1989) · JAMA · doi:10.1001/jama.261.22.3273 · Cited by 1,021
Inadequate Management of Blood Pressure in a Hypertensive Population
Berlowitz, D. R., Ash, A. S., Hickey, E. C., Friedman, R. H., Glickman, M., Kader, B., & Moskowitz, M. A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392701 · Cited by 959
Role of Blood Pressure in the Development of Congestive Heart Failure: The Framingham Study
Kannel, W. B., Castelli, W. P., McNamara, P. M., McKee, P. A., & Feinleib, M. (1972) · New England Journal of Medicine · doi:10.1056/nejm197210192871601 · Cited by 603
IMPROVEMENT OF MEDICATION COMPLIANCE IN UNCONTROLLED HYPERTENSION
Haynes, R. B., Gibson, E., Hackett, B., Sackett, D., Taylor, D. W., Roberts, R., & Johnson, A. (1976) · The Lancet · doi:10.1016/s0140-6736(76)91737-2 · Cited by 513
Redon, J., Campos, C., Narciso, M. L., Rodicio, J. L., Pascual, J. M., & Ruilope, L. M. (1998) · Hypertension · doi:10.1161/01.hyp.31.2.712 · Cited by 420
Colhoun, H. M., Dong, W., & Poulter, N. R. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00005 · Cited by 314
Psaty, B. M. (1990) · JAMA · doi:10.1001/jama.263.12.1653 · Cited by 268
Hypertension awareness, treatment and control in the community: is the ‘rule of halves’ still valid?
Marques-Vidal, P., & Tuomilehto, J. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000426 · Cited by 256
The Electronic Medication Event Monitor: Lessons for Pharmacotherapy
Urquhart, J. (1997) · Clinical Pharmacokinetics · doi:10.2165/00003088-199732050-00001 · Cited by 206
Resistant Hypertension in a Tertiary Care Clinic
Yakovlevitch, M. (1991) · Archives of Internal Medicine · doi:10.1001/archinte.151.9.1786 · Cited by 194
Desforges, J. F., Setaro, J. F., & Black, H. R. (1992) · New England Journal of Medicine · doi:10.1056/nejm199208203270808 · Cited by 130
Impact of an Electronic Medication Compliance Aid on Long‐Term Blood Pressure Control
McKenney, J. M., Munroe, W. P., & Wright, J. T. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03837.x · Cited by 120
Compliance with Antihypertensive Therapy
Waeber, B., Burnier, M., & Brunner, H. R. (1999) · Clinical and Experimental Hypertension · doi:10.3109/10641969909061025 · Cited by 99
Self-citationRisk factors for antihypertensive medication refill failure by patients under Medicaid managed care
Bailey, J. E., Lee, M. D., Somes, G. W., & Graham, R. L. (1996) · Clinical Therapeutics · doi:10.1016/s0149-2918(96)80080-4 · Cited by 81
Factors predictive of attendance at clinic and blood pressure control in hypertensive patients.
Patrice Degoulet, A., Ménard, J., Vu, H. A., Golmard, J., Devries, C., Châtellier, G., & Plouin, P. (1983) · BMJ · doi:10.1136/bmj.287.6385.88 · Cited by 74
TREATMENT OF REFRACTORY HYPERTENSION
Swales, J. D., Heagerty, A. M., Russell, G. I., Bing, R. F., Pohl, J., & Thurston, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92162-6 · Cited by 54
Mallion, J. M., Dutrey-Dupagne, C., Vaur, L., Genès, N., Renault, M., Elkik, F., Baguet, P., & Boutelant, S. (1996) · PubMed · Cited by 53
Cited by
Osterberg, L., & Blaschke, T. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050100 · Cited by 7,974
A systematic review of adherence with medications for diabetes
Cramer, J. A. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1218 · Cited by 1,203
Adherence in Hypertension: A Review of Prevalence, Risk Factors, Impact, and Management
Burnier, M., & Egan, B. M. (2019) · Circulation Research · doi:10.1161/circresaha.118.313220 · Cited by 878
Self-citationVrijens, B., Vincze, G., Kristanto, P., Urquhart, J., & Burnier, M. (2008) · BMJ · doi:10.1136/bmj.39553.670231.25 · Cited by 863
Self-citationCramer, J. A., Benedict, Á., Muszbek, N., Keskinaslan, A., & Khan, Z. M. (2007) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2007.01630.x · Cited by 487
Metadata
- Authors
- Burnier, M., Schneider, M. P., Chioléro, A., Stubi, C. L. F., & Brunner, H. R.
- Venue
- Journal of Hypertension
- Published
- 2001-02
- Volume
- 19
- Issue
- 2
- Pages
- 335-341
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2313754305
- Cited by
- 262
- References
- 22
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.