Raman Spectroscopy for Early Detection of Laryngeal Malignancy: Preliminary Results
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Objective Raman spectroscopy, the analysis of scattered photons after monochromatic laser excitation, is well established in nonbiological sciences. Recently this method has been used to differentiate premalignant and malignant lesions from normal tissue. Its application for early diagnosis has been explored in a variety of sites (e.g., esophagus, cervix), but not, to date, in laryngeal cancer. The objective of this study was to perform a feasibility study of the use of Raman spectroscopy for early diagnosis of laryngeal malignancy. Methods Biopsy specimens were snap‐frozen, and top sections were sent for histopathological analysis. Only homogenous samples with clearly defined pathological findings were used in this study: seven histologically normal samples, four exhibiting dysplasia, and four with carcinoma. Samples were defrosted and placed under a Renishaw (Wotton‐Under‐Edge, UK) System 1000 Raman microspectrometer for analysis. Between 5 and 12 spectra were acquired from each sample, with an excitation wavelength of 830 nm. Average characteristic spectra for each disease or condition were compared. Further multivariate statistical analysis of the data was carried out to evaluate and maximize the differences in the spectra for each disease or condition. Results The most visible differences in the spectra occur between 850 and 950 cm−1 and 1200 and 1350 cm−1. The later peaks are directly related to protein conformation and C‐H bond stretch in nucleic acid bases. The relative intensity of the nucleic acid peak increases with progression to malignancy. Use of linear discriminant analysis made it possible to separate the spectra with disease to a greater degree of accuracy than using empirical peak ratio methods alone. Classification results obtained from cross‐validation of the discriminant model showed prediction sensitivities of 83%, 76%, and 92% and specificities of 94%, 91%, and 90% for normal, dysplastic, and squamous cell carcinoma of the larynx, respectively. Conclusions There was strong evidence to support spectral identification of malignancy and earlier abnormal changes. More substantive studies of the spectral differences between malignant and non‐neoplastic tissue are warranted. Raman spectroscopy may become a useful adjunct to pathological diagnosis allowing directed or guided biopsies and assessment of adequacy of resection margins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herne, H., Cooley, W. W., & Lohnes, P. R. (1973) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344428 · Cited by 35,697
(1991) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(91)83004-v · Cited by 791
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475 · cited 2×
“The development of charge coupled device (CCD) detectors and solid-state semiconductor lasers has enabled the development of portable NIR Raman systems that produce spectra with high signal-to-noise ratio in short integration times.(4) Compatibility with fiber optics and the development of new probes is making in vivo…”
BackgroundMultivariate Analysis of Variance.
Morgan, D. D. V., Bray, J. H., & Maxwell, S. E. (1987) · The Statistician · doi:10.2307/2348846 · Cited by 453
Spectroscopy of biological systems
Johnson, P. (1987) · Endeavour · doi:10.1016/0160-9327(87)90264-x · Cited by 412
Histological Typing of Tumours of the Upper Respiratory Tract and Ear
Shanmugaratnam, K. (1991) · Springer eBooks · doi:10.1007/978-3-642-84474-4 · Cited by 375 · cited 1×
“limited numbers of samples, mild, moderate, and severe dysplasia were grouped together.(17) Only homogenous samples with clearly defined diseases or conditions were used in this investi-”
MethodNear‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical Precancers
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujamf, N., Malpica, A., Thomsen, S., Utzinger, U., & Richards‐Kortumt, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb03262.x · Cited by 282
Upper aerodigestive tract cancers
Muir, C., & Weiland, L. (1995) · Cancer · doi:10.1002/1097-0142(19950101)75:1+<147::aid-cncr2820751304>3.0.co;2-u · Cited by 248 · cited 1×
“Delayed diagnosis leading to locoregional failure and a high incidence of second primary malignancy in long-term survivors are the two main reasons for this poor outcome.(2) In addition, laryngeal cancer has the greatest effect on quality of life of any cancer, causing devastating lifestyle changes and resulting in pe…”
BackgroundRaman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170 · cited 2×
“Most biological molecules are Raman active, leading to distinctive spectral signatures (biochemical fingerprints) that represent a true form of optical histochemistry.(8) Suitable molecules for the study of neoplasia, as measured by Raman spectroscopy, include Fig.”
BackgroundGniadecka, M., Wulf, H. C., Nielsen, O. F., Christensen, D. H., & Hercogova, J. (1997) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1997.tb03167.x · Cited by 167 · cited 1×
“Indeed, recent studies have confirmed the feasibility of Raman spectroscopy for in vitro diagnosis of malignancy in skin, brain, breast, colon, and cervix.(8,10,14) These studies relied on changes in relative protein-to-lipid content (breast, cervix) or changes in protein structure and hydrogen bonding of proteins and…”
Background
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Self-citationNear‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Raman spectroscopy for identification of epithelial cancers
Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H. (2004) · Faraday Discussions · doi:10.1039/b304992b · Cited by 768
Self-citationMicro-Raman Spectroscopy Detects Individual Neoplastic and Normal Hematopoietic Cells
Chan, J. W., Taylor, D. S., Zwerdling, T., Lane, S. M., Ihara, K., & Huser, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.066761 · Cited by 679
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472
Self-citationFeng, S., Chen, R., Lin, J., Pan, J., Chen, G., Li, Y., Cheng, M., Huang, Z., Chen, J., & Zeng, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.033 · Cited by 450
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Gniadecka, M., Philipsen, P. A., Wessel, S., Gniadecki, R., Wulf, H. C., Sigurdsson, S., Nielsen, O. F., Christensen, D. H., Hercogova, J., Rossen, K., et al. (2004) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2004.22208.x · Cited by 350
Discriminating Basal Cell Carcinoma from its Surrounding Tissue by Raman Spectroscopy
Bakker Schut, T. C., Caspers, P. J., Puppels, G. J., Nijssen, A., Heule, F., Neumann, M. H. A., & Hayes, D. P. (2002) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2002.01807.x · Cited by 346
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Self-citationDiscrimination between ricin and sulphur mustard toxicity in vitro using Raman spectroscopy
Notingher, I., Green, C., Dyer, C., Perkins, E., Hopkins, N., Lindsay, C., & Hench, L. L. (2004) · Journal of The Royal Society Interface · doi:10.1098/rsif.2004.0008 · Cited by 291
Medical applications of Raman spectroscopy: From proof of principle to clinical implementation
Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J. (2002) · Biopolymers · doi:10.1002/bip.10064 · Cited by 280
Self-citationKendall, C., Stone, N., Shepherd, N., Geboes, K., Warren, B., Bennett, R., & Barr, H. (2003) · The Journal of Pathology · doi:10.1002/path.1376 · Cited by 245
Self-citationRaman microspectroscopy: a noninvasive tool for studies of individual living cells in vitro
Notingher, I., & Hench, L. L. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.2.215 · Cited by 230
Teh, S. K., Zheng, W., Ho, K. Y., Teh, M., Yeoh, K. G., & Huang, Z. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604176 · Cited by 230
“…respectively, also showed lower percentage signals for dysplasia tissue compared with the normal tissue, suggesting a decrease in the percentage of phospholipids, phenylalanine, and tryptophan relative to the total Raman-active constituents in the dysplasia (Stone et al, 2000; Huang et al, 2003).”
BackgroundMethodInfluentialFeng, S., Chen, R., Lin, J., Pan, J., Wu, Y., Li, Y., Chen, J., & Zeng, H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.020 · Cited by 224
“…SERS signals of human blood plasma, Table S2 lists tentative assignments for the observed SERS bands according to literature (Han et al., 2009; Uzunbajakava et al., 2003; Liu et al., 1992; Andrade et al., 2007; Stone et al., 2000; Gelder et al., 2007; Lyng et al., 2007; Movasaghi et al., 2007).”
BackgroundStone, N., Baker, R., Rogers, K., Parker, A. W., & Matousek, P. (2007) · The Analyst · doi:10.1039/b705029a · Cited by 195
Self-citationThe use of Raman spectroscopy to identify and grade prostatic adenocarcinoma in vitro
Crow, P., Stone, N., Kendall, C. A., Uff, J. S., Farmer, J. A. M., Barr, H., & Wright, M. P. J. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6601059 · Cited by 189
“Biopsies were classified as benign prostatic hyperplasia (BPH) or adenocarcinoma, with the adenocarcinoma group further split into three groups depending on Gleason score (GS less than seven, GS equal to seven and GS greater than seven).”
MethodResultSelf-citationAdvances in the clinical application of Raman spectroscopy for cancer diagnostics
Kallaway, C., Almond, L. M., Barr, H., Wood, J., Hutchings, J., Kendall, C., & Stone, N. (2013) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2013.01.008 · Cited by 186
“Raman spectroscopy (RS) is suitable for use with fibre-optic probes making it potentially ideal as a medical diagnostic tool for assessment of hollow organs [5—10].”
MethodSelf-citationLau, D. P., Huang, Z., Lui, H., Man, C. S., Berean, K., Morrison, M. D., & Zeng, H. (2003) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10084 · Cited by 185
“The use of RS for differentiating premalignant and malignant lesions from normal tissue has been studied for various sites including the brain [4], breast [5–8], gastro-intestinal tract [9–11], gynecologic tract [12–14], larynx [15], and skin [16].”
BackgroundMethodInfluentialRaman's “Effect” on Molecular Imaging
Zavaleta, C. L., Kircher, M. F., & Gambhir, S. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.087775 · Cited by 88
“In the head and neck region, Raman spectroscopy was able to discriminate between normal, dysplastic, and malignant changes in squamous epithelial cells of the larynx (94%, 91%, and 90% specificity, respectively, and 83%, 76%, and 92% sensitivity, respectively) (21) and has shown promise in differentiating benign from…”
BackgroundLloyd, G. R., Orr, L. E., Christie-Brown, J., McCarthy, K., Rose, S., Thomas, M., & Stone, N. (2013) · The Analyst · doi:10.1039/c2an36579k · Cited by 83
Self-citation
Metadata
- Authors
- Stone, N., Stavroulaki, P., Kendall, C., Birchall, M., & Barr, H.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2000-10
- Volume
- 110
- Issue
- 10
- Pages
- 1756-1763
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2007576973
- Cited by
- 228
- References
- 18
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.