Simultaneous monitoring of heart rate and motion to assess energy expenditure
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Measurement of energy expenditure in free-living individuals represents a methodologic challenge in epidemiologic research. Heart rate monitors, while closely tied to energy expenditure at high levels of energy output, provide much less predictive power at low levels; however, measurement of motion may improve the predictive ability. This study was undertaken to determine the usefulness of simultaneously monitoring heart rate and motion for the estimation of energy expenditure. Ten subjects were studied during simulated activities of daily living (ADLC) and submaximal treadmill tests. Compared to direct measurement, the motion sensor predicted oxygen consumption poorly (r2 = 0.53) for both tests. Heart rate measured simultaneously yielded an r2 of 0.81 for ADLC and 0.90 for the treadmill. Addition of motion data increased the r2 value for the ADLC for all but one individual and increased the group mean from 0.81 to 0.86. This improvement was not observed for the treadmill, confirming the hypothesis that the principle value of monitoring motion occurs at lower heart rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paffenbarger, R. S., Hyde, R. T., Wing, A. L., Lee, I.-M., Jung, D. L., & Kampert, J. B. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302253280804 · Cited by 1,972
Physical activity and reduced occurrence of non–insulin-dependent diabetes mellitus
Helmrich, S. P., Ragland, D. R., Leung, R. W., & Paffenbarger, R. S. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107183250302 · Cited by 1,634
Cited by
Heart Rate Monitoring: Applications and Limitations
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,166
Measurement Issues in the Assessment of Physical Activity in Children
Welk, G. J., Corbin, C. B., & Dale, D. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082788 · Cited by 782
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Esliger, D. W., Copeland, J. L., Barnes, J. D., & Tremblay, M. S. (2005) · Journal of Physical Activity and Health · doi:10.1123/jpah.2.3.366 · Cited by 388
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336
Prediction of energy expenditure from heart rate monitoring during submaximal exercise
Keytel, L., Goedecke, J., Noakes, T., Hiiloskorpi, H., Laukkanen, R., van der Merwe, L., & Lambert, E. (2005) · Journal of Sports Sciences · doi:10.1080/02640410470001730089 · Cited by 331
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
“Thus, some researchers have proposed the use of HR and accelerometry in combination to improve the estimate of physical activity energy expenditure (Haskell et al., 1993; Moon and Butte, 1996; Luke et al., 1997; Rennie et al., 2000; Strath et al., 2001; Brage et al., 2004).”
BackgroundImproving Energy Expenditure Estimation for Physical Activity
ZHANG, K., PI-SUNYER, F. X., & BOOZER, C. N. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126585.40962.22 · Cited by 180
“(14) pointed out, the accurate measurement of PA and EE is problematic, and all of the existing measurement techniques have significant limitations.”
BackgroundMeasurement Methods for Physical Activity and Energy Expenditure: a Review
Ndahimana, D., & Kim, E.-K. (2017) · Clinical Nutrition Research · doi:10.7762/cnr.2017.6.2.68 · Cited by 179
“However, this correlation is low in case of sedentary and light activities, and it remains one of the limitations of heart rate monitors [68,70,71].”
BackgroundWristband-type wearable health devices to measure construction workers' physical demands
Hwang, S., & Lee, S. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.06.003 · Cited by 168
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Simultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Integration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
A combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
“Correlations using both heart rate and motion sensors for activities at low-to-moderate heart rates compared to heart rate alone increased by up to 0.13 on an individual basis (Luke et al, 1997).”
MethodInfluentialOccupational physical activity in brewery and office workers
Thompson, J. F., Severson, R. L., & Rosecrance, J. C. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1492136 · Cited by 9
Metadata
- Authors
- LUKE, A., MAKI, K. C., BARKEY, N., COOPER, R., & McGEE, D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-01
- Volume
- 29
- Issue
- 1
- Pages
- 144-148
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2089786860
- Cited by
- 97
- References
- 2
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.