CoChat

Substrate utilization and glucose turnover during exercise of varying intensities in individuals with NIDDM

KANG, JIE, KELLEY, DAVID E., ROBERTSON, ROBERT J., GOSS, FREDRIC L., SUMINSKI, RICHARD R., UTTER, ALAN C., DASILVA, SERGIO G. · 1999 · Medicine & Science in Sports & Exercise
Cited by 70

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: This investigation was undertaken to examine substrate utilization and glucose turnover during exercise of varying intensities in NIDDM patients. METHODS: Six male NIDDM patients (N) and six male controls (C) of similar age, body weight, % body fat, and VO2peak were studied in two experimental sessions administered in a randomized counterbalanced order. During each session the subjects cycled at a power output corresponding to 50% of VO2peak or 70% of VO2peak. Duration of exercise was adjusted so that energy expenditure (EE) was equal in both the 50% and 70% trials. Isotope infusion technique and indirect calorimetry were used to assess substrate utilization and glucose turnover during exercise. RESULTS: Rates of carbohydrate (CHO) and lipid oxidation increased (P < 0.05) during both the 50% and 70% trials. Rates of CHO oxidation were greater (P < 0.05) during the 70% than during the 50% trial. However, rates of lipid oxidation were similar in the two trials. No differences in rates of CHO and lipid oxidation were observed in N and C. Rates of hepatic glucose production (Ra) and plasma glucose utilization (Rd) increased (P < 0.05) during exercise, and the increases were similar in the 50% and 70% trials. Ra did not differ between N and C. However, Rd was greater (P < 0.05) in N than in C. Plasma glucose concentration decreased (P < 0.05) in N, with the decrease being similar in the 50% and 70% trials. In contrast, plasma glucose concentration remained unchanged during both the 50% and 70% trials in C. CONCLUSIONS: Exercise results in a greater increase in plasma glucose utilization in patients with NIDDM compared with that in normal individuals, and this increase mediates the decline in plasma glucose concentrations in patients with NIDDM. Under isocaloric conditions, the changes in plasma glucose utilization and plasma glucose concentrations are similar during exercise of varying intensities. Despite a greater glucose utilization, carbohydrate and fat oxidation are similar in the two groups and their relations to exercise intensity are not altered by NIDDM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199901000-00014

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 70

Metadata

Authors
KANG, J., KELLEY, D. E., ROBERTSON, R. J., GOSS, F. L., SUMINSKI, R. R., UTTER, A. C., & DASILVA, S. G.
Venue
Medicine & Science in Sports & Exercise
Published
1999-01
Volume
31
Issue
1
Pages
82-89
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2010219645
Cited by
70
References
7
FWCI
5.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Substrate utilization and glucose turnover during exercise of varying intensities in individuals with NIDDM. https://app.cochat.ai/papers/10.1097/00005768-199901000-00014
The paper
KANG, J., KELLEY, D. E., ROBERTSON, R. J., GOSS, F. L., SUMINSKI, R. R., UTTER, A. C., & DASILVA, S. G. (1999). Substrate utilization and glucose turnover during exercise of varying intensities in individuals with NIDDM. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199901000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.