Brain Lab VectorVision Neuronavigation System: Technology and Clinical Experiences in 131 Cases
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The BrainLab VectorVision neuronavigation system was used in 131 cases of different brain pathological conditions. The neuronavigation system was used without problems in 125 cases. These cases included 114 microsurgical operations, 4 endoscopic procedures, 4 frameless stereotactic biopsies, and 3 catheter placements. METHODS: The BrainLab VectorVision neuronavigation system is an intraoperative, image-guided, frameless, localization system. The system consists of a computer workstation for registration of images and physical spaces, an intraoperative localization device, and a computer image display. The system provides real-time responses regarding the locations of surgical instruments. VectorVision is based on passive reflections of infrared flashes. Universal adapters with reflective markers for surgical instruments, endoscopes, and the operating microscope are used. RESULTS: In six cases, the system could not be used because of system failure or mishandling. In 125 neurosurgical cases, the neuronavigation system was useful, with a target-localizing accuracy of 4+/-1.4 mm (mean+/-standard deviation). For small cerebral lesions, we never performed an exploration with negative results. CONCLUSION: The BrainLab neuronavigation system has been shown to be very helpful and user-friendly for routine neurosurgical interventions. Its advantage lies in its mobility, based on wireless reflective adapters for surgical instruments, endoscopes, and the operating microscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stereotaxic Apparatus for Operations on the Human Brain
Spiegel, E. A., Wycis, H. T., Marks, M., & Lee, A. J. (1947) · Science · doi:10.1126/science.106.2754.349 · Cited by 982
THE STRUCTURE AND FUNCTIONS OF THE CEREBELLUM EXAMINED BY A NEW METHOD.
HORSLEY, V., & CLARKE, R. H. (1908) · Brain · doi:10.1093/brain/31.1.45 · Cited by 783
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Frameless stereotaxic integration of CT imaging data: accuracy and initial applications.
Zinreich, S. J., Tebo, S. A., Long, D. M., Brem, H., Mattox, D. E., Loury, M. E., vander Kolk, C. A., Koch, W. M., Kennedy, D. W., & Bryan, R. N. (1993) · Radiology · doi:10.1148/radiology.188.3.8351341 · Cited by 244
Interactive image-guided neurosurgery
Galloway, R. L., Maciunas, R. J., & Edwards, C. A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184698 · Cited by 229
Smith, K. R., Frank, K. J., & Bucholz, R. D. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90049-3 · Cited by 166
Frameless neuronavigation in modern neurosurgery
Spetzger, U., Laborde, G., & Gilsbach, J. (1995) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2008-1053478 · Cited by 107
Cited by
Duffau, H. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70140-x · Cited by 683
Current Clinical Brain Tumor Imaging
Villanueva-Meyer, J. E., Mabray, M. C., & Cha, S. (2017) · Neurosurgery · doi:10.1093/neuros/nyx103 · Cited by 453
Structural Brain Alterations following 5 Days of Intervention: Dynamic Aspects of Neuroplasticity
May, A., Hajak, G., Gänßbauer, S., Steffens, T., Langguth, B., Kleinjung, T., & Eichhammer, P. (2007) · Cerebral Cortex · doi:10.1093/cercor/bhj138 · Cited by 344
Deep brain stimulation for Parkinson's disease: Surgical technique and perioperative management
Machado, A., Rezai, A. R., Kopell, B. H., Gross, R. E., Sharan, A. D., & Benabid, A.-L. (2006) · Movement Disorders · doi:10.1002/mds.20959 · Cited by 324
Brain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Computer assisted oral and maxillofacial surgery – a review and an assessment of technology
Hassfeld, S., & Mühling, J. (2001) · International Journal of Oral and Maxillofacial Surgery · doi:10.1054/ijom.2000.0024 · Cited by 263
Unsgaard, G., Ommedal, S., Muller, T., Gronningsaeter, A., & Nagelhus Hernes, T. A. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00022 · Cited by 262
Mabray, M. C., Barajas, R. F., & Cha, S. (2015) · Brain Tumor Research and Treatment · doi:10.14791/btrt.2015.3.1.8 · Cited by 237
“High-resolution iso-volumetric sequences such as high-resolution 3D T2 sequences and postgadolinium T1 spoiled gradient recalled acquisition (SPGR) or similar sequences are generally performed preoperatively with fiducials in place for use with intraoperative navigational software [64,65].”
Image-to-patient registration techniques in head surgery
Eggers, G., Mühling, J., & Marmulla, R. (2006) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2006.09.015 · Cited by 214
The Insular Lobe: Physiopathological and Surgical Considerations
Duffau, H., Capelle, L., Lopes, M., Faillot, T., Sichez, J.-P., & Fohanno, D. (2000) · Neurosurgery · doi:10.1097/00006123-200010000-00001 · Cited by 206
Computer-aided navigation in neurosurgery
Grunert, P., Darabi, K., Espinosa, J., & Filippi, R. (2003) · Neurosurgical Review · doi:10.1007/s10143-003-0262-0 · Cited by 192
Theta Oscillations in the Human Medial Temporal Lobe during Real-World Ambulatory Movement
M. Aghajan, Z., Schuette, P., Fields, T. A., Tran, M. E., Siddiqui, S. M., Hasulak, N. R., Tcheng, T. K., Eliashiv, D., Mankin, E. A., Stern, J., et al. (2017) · Current Biology · doi:10.1016/j.cub.2017.10.062 · Cited by 186
Laser Surface Scanning for Patient Registration in Intracranial Image-guided Surgery
Raabe, A., Krishnan, R., Wolff, R., Hermann, E., Zimmermann, M., & Seifert, V. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00021 · Cited by 185
Krishnan, R., Raabe, A., Hattingen, E., Szelényi, A., Yahya, H., Hermann, E., Zimmermann, M., & Seifert, V. (2004) · Neurosurgery · doi:10.1227/01.neu.0000137331.35014.5c · Cited by 174
Willems, P. W. A., Taphoorn, M. J. B., Burger, H., van der Sprenkel, J. W. B., & Tulleken, C. A. F. (2006) · Journal of Neurosurgery · doi:10.3171/jns.2006.104.3.360 · Cited by 163
Rasmussen, I.-A., Lindseth, F., Rygh, O. M., Berntsen, E. M., Selbekk, T., Xu, J., Nagelhus Hernes, T. A., Harg, E., Håberg, A., & Unsgaard, G. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-006-1110-0 · Cited by 163
“Neuronavigation systems are continuously being refined in order to minimize invasiveness and post-surgical morbidity at the same time as the radicality is maximized [7, 12, 38].”
BackgroundEichhammer, P., Langguth, B., Marienhagen, J., Kleinjung, T., & Hajak, G. (2003) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01896-6 · Cited by 162
Bayesian Characterization of Uncertainty in Intra-subject Non-rigid Registration
Risholm, P., Janoos, F., Norton, I., Golby, A. J., & Wells, W. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.002 · Cited by 62
“Current image guided navigation systems use rigid registration to map between the pre-and intra-operative space (Shamir et al., 2009; Gumprecht et al., 1999), and researchers have focused on estimating the distribution of errors in rigid registration, especially in fiducial-based registration where…”
Background
Metadata
- Authors
- Gumprecht, H. K., Widenka, D. C., & Lumenta, C. B.
- Venue
- Neurosurgery
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 1
- Pages
- 97-104
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2025258633
- Cited by
- 264
- References
- 7
- FWCI
- 14.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.