The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES
Abstract
OBJECTIVE: Device-related infection is a common complication of deep brain stimulator (DBS) implantation. We reviewed the incidence and management of early hardware-related infections in a large series. METHODS: All patients undergoing DBS implantation surgery between 1998 and 2006 at a single institution were entered into a prospectively designed database. After database verification by cross-referencing manufacturer implantation records, a query was performed to include all new Medtronic (Minneapolis, MN) implantations performed with standard operating room technique. Hardware-related infections requiring further surgery were identified, and charts were reviewed to assess the success of lead-sparing partial hardware removal in this group. RESULTS: Four hundred twenty patients received 759 new DBS electrodes and 615 new internal pulse generators for the treatment of movement disorders or pain. Nineteen patients (4.5%) had an early (<6 mo) hardware-related infection requiring further surgery. There were no intracranial infections. Four patients presented with extensive cellulitis or wound dehiscence and were treated with total hardware removal. Fourteen patients presented with more localized infections and were treated by removal of the involved components only, followed by intravenously administered antibiotics. In nine of these patients, partial hardware removal successfully resolved the infection without requiring removal of the DBS electrodes. Wound washout alone was attempted in one patient and failed. CONCLUSION: In a large series of new DBS hardware implantations, the incidence of postoperative hardware-related infection requiring further surgery was 4.5%. When only one device component was involved, partial hardware removal was often successful.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Research works printed but not linked: 32
- Aggarwal, 1995, Early complications of permanent pacemaker implantation: No difference between dual and single chamber systems., Br Heart J, 73, 571, 10.1136/hrt.73.6.571 · DOI · Paper page
- Beric, 2001, Complications of deep brain stimulation surgery., Stereotact Funct Neurosurg, 77, 73, 10.1159/000064600 · DOI · Paper page
- Blomstedt, 2005, Hardware-related complications of deep brain stimulation: A ten year experience., Acta Neurochir (Wien), 147, 1061, 10.1007/s00701-005-0576-5 · DOI · Paper page
- Constantoyannis, 2005, Reducing hardware-related complications of deep brain stimulation., Can J Neurol Sci, 32, 194, 10.1017/S0317167100003966 · DOI
- Coubes, 2002, Deep brain stimulation for dystonia. Surgical technique., Stereotact Funct Neurosurg, 78, 183, 10.1159/000068962 · DOI
- Darouiche, 2004, Treatment of infections associated with surgical implants., N Engl J Med, 350, 1422, 10.1056/NEJMra035415 · DOI · Paper page
- Haines, 1994, Antibiotic prophylaxis for cerebrospinal fluid shunts: A metanalysis., Neurosurgery, 34, 87
- Ido, 1996, Suction/irrigation for deep wound infection after spinal instrumentation: A case study., Eur Spine J, 5, 345, 10.1007/BF00304351 · doi:10.1007/bf00304351
- Koller, 1997, High-frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor., Ann Neurol, 42, 292, 10.1002/ana.410420304 · DOI · Paper page
- Kondziolka, 2002, Hardware-related complications after placement of thalamic deep brain stimulator systems., Stereotact Funct Neurosurg, 79, 228, 10.1159/000070836 · DOI
- Kumar, 1997, Deep brain stimulation for intractable pain: A 15-year experience., Neurosurgery, 40, 736, 10.1097/00006123-199704000-00015 · DOI · Paper page
- Levy, 1987, Treatment of chronic pain by deep brain stimulation: Long term follow-up and review of the literature., Neurosurgery, 21, 885, 10.1227/00006123-198712000-00017 · DOI · Paper page
- Limousin, 1999, Multicentre European study of thalamic stimulation in parkinsonian and essential tremor., J Neurol Neurosurg Psychiatry, 66, 289, 10.1136/jnnp.66.3.289 · DOI · Paper page
- Lyons, 2001, Surgical and device-related events with deep brain stimulation (abstract)., Neurology, 56, A146
- Lyons, 2004, Surgical and hardware complications of subthalamic stimulation: A series of 160 procedures., Neurology, 63, 612, 10.1212/01.WNL.0000134650.91974.1A · DOI · Paper page
- Martin, 2005, Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging., Magn Reson Med, 54, 1107, 10.1002/mrm.20675 · DOI
- Masterson, 1984, Bacteriologic evaluation of electric clippers for surgical hair removal., Am J Surg, 148, 301, 10.1016/0002-9610(84)90458-6 · doi:10.1016/0002-9610(84)90458-6
- Merello, 2001, Delayed intracerebral electrode infection after bilateral STN implantation for Parkinsons disease. Case report., Mov Disord, 16, 168, 10.1002/1531-8257(200101)16:1<168::AID-MDS1032>3.0.CO;2-N · doi:10.1002/1531-8257(200101)16:1<168::aid-mds1032>3.0.co;2-n
- Oh, 2002, Long-term hardware-related complications of deep brain stimulation., Neurosurgery, 50, 1268
- Schuurman, 2000, A comparison of continuous thalamic stimulation and thalamotomy for suppression of severe tremor., N Engl J Med, 342, 461, 10.1056/NEJM200002173420703 · DOI · Paper page
- Seal, 2004, A systems approach to preoperative surgical patient skin preparation., Am J Infect Control, 32, 57, 10.1016/j.ajic.2003.11.001 · doi:10.1016/j.ajic.2003.11.001
- Starr, 2002, Implantation of deep brain stimulators into the subthalamic nucleus: Technical approach and magnetic resonance imaging-verified lead locations., J Neurosurg, 97, 370, 10.3171/jns.2002.97.2.0370 · DOI · Paper page
- Temel, 2004, Management of hardware infections following deep brain stimulation., Acta Neurochir (Wien), 146, 355, 10.1007/s00701-004-0219-2 · DOI
- Tulipan, 2006, Effect of an intraoperative double-gloving strategy on the incidence of cerebrospinal fluid shunt infection., J Neurosurg, 104, 5
- Vingerhoets, 2002, : Results and adverse events in 50 consecutive patients treated by STN-DBS., Mov Disord, 17, 666
- Voges, 2006, Deep-brain stimulation: Long-term analysis of complications caused by hardware and surgeryexperiences from a single centre., J Neurol Neurosurg Psychiatry, 77, 868, 10.1136/jnnp.2005.081232 · DOI · Paper page
- Constantoyannis, 2005, Reducing hardware-related complications of deep brain stimulation., Can J Neurol Sci, 32, 194, 10.1017/S0317167100003966 · DOI
- Hamani, 2006, Hardware-related complications of deep brain stimulation: A review of the published literature., Stereotact Funct Neurosurg, 84, 248, 10.1159/000096499 · DOI · Paper page
- Oh, 2002, Long-term hardware-related complications of deep brain stimulation., Neurosurgery, 50, 1268
- Temel, 2004, Management of hardware infections following deep brain stimulation., Acta Neurochir (Wien), 146, 355, 10.1007/s00701-004-0219-2 · DOI
- Voges, 2007, Thirty days complication rate following surgery performed for deep-brain-stimulation., Mov Disord, 22, 1486, 10.1002/mds.21481 · DOI · Paper page
- Voges, 2006, Deep-brain stimulation: Long-term analysis of complications caused by hardware and surgeryExperiences from a single centre., J Neurol Neurosurg Psychiatry, 77, 868, 10.1136/jnnp.2005.081232 · DOI · Paper page
Cited by
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Deep-Brain Stimulation for Parkinson's Disease
Okun, M. S. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1208070 · Cited by 541
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Review: Deep brain stimulation in Parkinson’s disease
Groiss, S. J., Wojtecki, L., Südmeyer, M., & Schnitzler, A. (2009) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756285609339382 · Cited by 280
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Metadata
- Authors
- Sillay, K. A., Larson, P. S., & Starr, P. A.
- Venue
- Neurosurgery
- Published
- 2008-02
- Volume
- 62
- Issue
- 2
- Pages
- 360-367
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1964469897
- Cited by
- 225
- References
- 1
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES. https://app.cochat.ai/papers/10.1227/01.neu.0000316002.03765.33
- The paper
- Sillay, K. A., Larson, P. S., & Starr, P. A. (2008). DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES. Neurosurgery. https://doi.org/10.1227/01.neu.0000316002.03765.33
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.