Complications of Lumbar Spinal Fusion with Transpedicular Instrumentation
The DOI matches its Crossref record.
Abstract
Transpedicular screw fixation systems are coming into wide use as an adjunct to lumbar spinal fusion procedures. This 5-year series included 486 patients who underwent 533 variable screw placement procedures for discal, degenerative, and spondylolytic problems. The wound infection rate was 2.6%: 0.6% deep, 0.9% graft, and 1.1% superficial. The neural injury rate was 1.1% overall: 0.6% related to posterior lumbar interbody fusion and 0.6% related to instrumentation. Technical problems per procedure included 8.1% difficult screw placement, 5.6% nut loosening, and 4.3% screw breakage (1.1% per screw placed). Device modifications have reduced the incidence of screw breakage and nut loosening. No device-related neural injuries occurred in the last 333 procedures. With experience, the device can be applied safely without significantly increasing the risk of neural injury or morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kuslich, S. D., Ulstrom, C. L., Griffith, S. L., Ahern, J. W., & Dowdle, J. D. (1998) · Spine · doi:10.1097/00007632-199806010-00019 · Cited by 508
Threaded Titanium Cages for Lumbar Interbody Fusions
Ray, C. D. (1997) · Spine · doi:10.1097/00007632-199703150-00019 · Cited by 452
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
Complications associated with single-level transforaminal lumbar interbody fusion
Rihn, J. A., Patel, R., Makda, J., Hong, J., Anderson, D. G., Vaccaro, A. R., Hilibrand, A. S., & Albert, T. J. (2009) · The Spine Journal · doi:10.1016/j.spinee.2009.04.004 · Cited by 286
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Worldwide Survey on the Use of Navigation in Spine Surgery
Härtl, R., Lam, K. S., Wang, J., Korge, A., Kandziora, F., & Audigé, L. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2012.03.011 · Cited by 270
Christensen, F. B., Hansen, E. S., Eiskjær, S. P., Høy, K., Helmig, P., Neumann, P., Niedermann, B., & Bünger, C. E. (2002) · Spine · doi:10.1097/00007632-200212010-00006 · Cited by 202
“When performed by experienced surgeons, pedicle screw insertion is a relatively safe procedure.(12,13,18,28,49) Deep vein thrombosis, vascular injury, retrograde ejaculation, and other complications have been reported with the anterior approach.”
BackgroundFusion for low-grade adult isthmic spondylolisthesis: a systematic review of the literature
Jacobs, W. C. H., Vreeling, A., & De Kleuver, M. (2006) · European Spine Journal · doi:10.1007/s00586-005-1021-4 · Cited by 194
“Davne [8] reported 4.”
InfluentialA Randomized Study of Closed Wound Suction Drainage for Extensive Lumbar Spine Surgery
Brown, M. D., & Brookfield, K. F. W. (2004) · Spine · doi:10.1097/00007632-200405150-00003 · Cited by 173
Nottmeier, E. W., Seemer, W., & Young, P. M. (2009) · Journal of Neurosurgery: Spine · doi:10.3171/2008.10.spi08383 · Cited by 160
Metadata
- Authors
- Davne, S. H., & Myers, D. L.
- Venue
- Spine
- Published
- 1992-06
- Volume
- 17
- Issue
- Supplement
- Pages
- S184-S189
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1964365374
- Cited by
- 248
- References
- 0
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.