Load Sharing Between the Shell and Centrum in the Lumbar Vertebral Body
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: A finite element parametric analysis to investigate the relative load carrying roles of the shell and centrum in the lumbar vertebral body. OBJECTIVE: To address the issue of the structural role of the vertebral shell and clarify some of the contradictions raised by previous studies. SUMMARY OF BACKGROUND DATA: A number of experimental and finite element studies have attempted to quantify the relative structural roles of the shell and centrum, but these studies support no consensus on the relative contribution of the shell to vertebral body strength. METHODS: The authors developed finite element models to predict the fraction of the total compressive force acting on the lumbar vertebral body that is carried by the shell. Parametric variations were investigated to determine how the fraction of shell force was affected by changes in shell thickness, shell and centrum modulus, centrum anistropy, and loading conditions. RESULTS: The fraction of compressive force carried by the shell increased from approximately 0 at the endplate to approximately 0.2 at the mid-transverse plane for a typical case. The shell force was highly sensitive to the degree of anisotropy of the trabecular centrum but was relatively insensitive to changes in shell thickness and the ratio of shell-to-centrum elastic modulus. CONCLUSIONS: The conflicting conclusions of previous studies about the structural roles of the vertebral shell and centrum can be explained by differences in their methods. Our findings support the claims that the shell accounts for only approximately 10% of vertebral strength in vivo and that the trabecular centrum is the dominant structural component of the vertebral body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Riggs, B. L., & Melton, L. J. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606263142605 · Cited by 1,915
Classification of vertebral fractures
Eastell, R., Cedel, S. L., Wahner, H. W., Riggs, B. L., & Dr. Melton, L. J. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060302 · Cited by 610
The Load on Lumbar Disks in Different Positions of the Body
NACHEMSON, A. (1966) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-196600450-00014 · Cited by 570
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Lumbar Intradiscal Pressure: Experimental Studies on Post-Mortem Material
Nachemson, A. (1960) · Acta Orthopaedica Scandinavica · doi:10.3109/ort.1960.31.suppl-43.01 · Cited by 494
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Schultz, A., Andersson, G., Ortengren, R., Haderspeck, K., & Nachemson, A. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264050-00008 · Cited by 453
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Self-citationElastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae
Rockoff, S. D., Sweet, E., & Bleustein, J. (1969) · Calcified Tissue Research · doi:10.1007/bf02058659 · Cited by 372
Internal Intervertebral Disc Mechanics as Revealed by Stress Profilometry
McNALLY, D. S., & ADAMS, M. A. (1992) · Spine · doi:10.1097/00007632-199201000-00011 · Cited by 369
Variations in strength of vertebrae with age and their relation to osteoporosis
Bell, G. H., Dunbar, O., Beck, J. S., & Gibb, A. (1967) · Calcified Tissue Research · doi:10.1007/bf02008077 · Cited by 347
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationA 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Self-citationPhysical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
Mosekilde, L., & Mosekilde, L. (1986) · Bone · doi:10.1016/8756-3282(86)90019-0 · Cited by 247
Biologically meaningful determinants of the in vitro strength of lumbar vertebrae
Vesterby, A., Mosekilde, L., Gundersen, H. J. G., Melsen, F., Mosekilde, L., Holme, K., & Sørensen, S. (1991) · Bone · doi:10.1016/8756-3282(91)90044-j · Cited by 233
A comparison of morphometric definitions of vertebral fracture
Smith-Bindman, R., Cummings, S. R., Steiger, P., & Genant, H. K. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060106 · Cited by 221
Faulkner, K. G., Cann, C. E., & Hasegawa, B. H. (1991) · Radiology · doi:10.1148/radiology.179.3.2027972 · Cited by 215
Silva, M. J., Wang, C., Keaveny, T. M., & Hayes, W. C. (1994) · Bone · doi:10.1016/8756-3282(94)90817-6 · Cited by 210
Self-citationFracture of the Vertebral End-Plate in the Lumbar Spine: An Experimental Biomechanical Investigation
Perey, O. (1957) · Acta Orthopaedica Scandinavica · doi:10.3109/ort.1957.28.suppl-25.01 · Cited by 190
The clinical biomechanics award paper 1993 Posture and the compressive strength of the lumbar spine
Adams, M. A., McNally, D. S., Chinn, H., & Dolan, P. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90052-3 · Cited by 164
Vertebral structure and strengthIn vivo andIn vitro
Mosekilde, L. (1993) · Calcified Tissue International · doi:10.1007/bf01673420 · Cited by 158
Correlations Between Vertebral Regional Bone Mineral Density (rBMD) and Whole Bone Fracture Load
CODY, D. D., GOLDSTEIN, S. A., FLYNN, M. J., & BROWN, E. B. (1991) · Spine · doi:10.1097/00007632-199102000-00009 · Cited by 152
Mosekilde, L., Viidik, A., & Mosekilde, L. (1985) · Bone · doi:10.1016/8756-3282(85)90317-5 · Cited by 136
Theoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136
Self-citationKurowski, P., & Aizoh, K. U. B. O. (1986) · Spine · doi:10.1097/00007632-198609000-00012 · Cited by 132
Fracture risk: A role for compact bone
Mazess, R. B. (1990) · Calcified Tissue International · doi:10.1007/bf02555918 · Cited by 128
Tensile testing of rodlike trabeculae excised from bovine femoral bone
Ryan, S. D., & Williams, J. L. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90049-3 · Cited by 118
Finite-Element Stress Analysis of the Normal and Osteoporotic Lumbar Vertebral Body
Mizrahi, J., Silva, M. J., Keaveny, T. M., Edwards, W. T., & Hayes, W. C. (1993) · Spine · doi:10.1097/00007632-199310001-00028 · Cited by 93
Self-citationFunctional biomechanics of the thoracolumbar vertebral cortex
Yoganandan, N., Mykiebust, J. B., Cusick, J. F., Wilson, C. R., & Sances, A. (1988) · Clinical Biomechanics · doi:10.1016/0268-0033(88)90119-2 · Cited by 88
The apparent elastic modulus of the juxtaricular subchondral bone of the femoral head
Brown, T. D., & Vrahas, M. S. (1984) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100020106 · Cited by 79
Effects of porous coating and collar support on early load transfer for a cementless hip prosthesis
Keaveny, T. M., & Bartel, D. L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90068-p · Cited by 55
Self-citation
Cited by
Cortical and Trabecular Load Sharing in the Human Vertebral Body
Eswaran, S. K., Gupta, A., Adams, M. F., & Keaveny, T. M. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2006.21.2.307 · Cited by 307
Self-citationPolikeit, A., Ferguson, S. J., Nolte, L. P., & Orr, T. E. (2003) · European Spine Journal · doi:10.1007/s00586-002-0505-8 · Cited by 287
Biomechanics of the aging spine
Ferguson, S. J., & Steffen, T. (2003) · European Spine Journal · doi:10.1007/s00586-003-0621-0 · Cited by 257
Toward Strong and Tough Glass and Ceramic Scaffolds for Bone Repair
Fu, Q., Saiz, E., Rahaman, M. N., & Tomsia, A. P. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201301121 · Cited by 247
Nazarian, A., von Stechow, D., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 244
Metadata
- Authors
- Silva, M. J., Keaveny, T. M., & Hayes, W. C.
- Venue
- Spine
- Published
- 1997-01
- Volume
- 22
- Issue
- 2
- Pages
- 140-150
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2167665629
- Cited by
- 195
- References
- 33
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.