CoChat

Randomized Radiostereometric Study Comparing Osteogenic Protein-1 (BMP-7) and Autograft Bone in Human Noninstrumented Posterolateral Lumbar Fusion: 2002 Volvo Award in Clinical Studies

Johnsson, Ragnar, Strömqvist, Björn, Aspenberg, Per · 2002 · Spine
Cited by 202

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

STUDY DESIGN: Randomized efficacy trial comparing two types of noninstrumented posterolateral fusion between L5 and S1 in patients with L5 spondylolysis and vertebral slip less than 50%, as evaluated by radiostereometric analysis. OBJECTIVE: To determine whether osteogenic protein-1 (BMP-7) in the OP-1 Implant yields better stabilizing bony fusion than autograft bone. SUMMARY OF BACKGROUND DATA: Animal studies of osteoinductive proteins in noninstrumented posterolateral fusions have shown high fusion rates. No similar conclusive study on humans has been performed. METHODS: For this study, 20 patients were randomized to fusion with either OP-1 Implant or autograft bone from the iliac crest, 10 in each group. The patients were instructed to keep the trunk straight for 5 months after surgery with the aid of a soft lumbar brace. At surgery 0.8-mm metallic markers were positioned in L5 and the sacrum, enabling radiostereometric follow-up analysis during 1 year. The three-dimensional vertebral movements, as measured by radiostereometric analysis induced by positional change from supine posture to standing and sitting, were calculated with an accuracy of 0.5 to 0.7 mm and 0.5 degrees to 2.0 degrees. Conventional radiography was added. RESULTS: No significant difference was noted between the radiostereometric and radiographic results of fusion with the OP-1 Implant and fusion with autograft bone. There was a significant relation between reduced vertebral movements and better bone formation. No adverse effects of the OP-1 Implant occurred. Persistent minor pain at the iliac crest was noticed in one patient. CONCLUSIONS: There was no significant difference between the two fusion versions. Thus, the OP-1 Implant did not yield better stabilizing bony fusion than autograft bone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-200212010-00004

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 202

Metadata

Authors
Johnsson, R., Strömqvist, B., & Aspenberg, P.
Venue
Spine
Published
2002-12
Volume
27
Issue
23
Pages
2654-2661
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2068833139
Cited by
202
References
8
FWCI
10.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.