A speedy solution for balance and gait analysis: angular velocity measured at the centre of body mass
Abstract
PURPOSE OF REVIEW: Falls are a serious problem for the elderly and others prone to fall. In particular, those over 65 years of age will suffer at least one fall a year and as a result will need cost-intensive medical treatment. Under these circumstances, an optimal clinical pathway should first identify those with a tendency to fall, second, pinpoint the disease-specific deficits in balance control and walking patterns, and third, offer the possibility through focused biofeedback training to reduce the number of falls suffered. This review describes new methods of assessing balance control in both static and dynamic balance conditions and their applications for balance rehabilitation. RECENT FINDINGS: Technological advances and applied research have shown that body-worn sensors measuring angular velocity (gyroscopes) or the acceleration of the trunk can effectively quantify balance during stance and gait tasks, and can be used to detect potential fallers and discriminate between different balance disorders. Standing on foam support reveals balance deficits regardless of the underlying disease. Disease-specific balance deficits can be characterized by the pattern of trunk movements between various semi-stance and gait tasks. Angular velocity sensors have recently been shown to provide highly relevant information for use as biofeedback, or as an ambulatory device to record balance and gait performance over long periods of time in both clinical and natural living conditions. SUMMARY: Angular velocity sensors can provide balance-relevant information directly to the clinician, and provide an important improvement on the complicated and time/cost-intensive techniques of traditional balance measurement systems.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Body-worn gyroscopes measuring angular velocity, sensors to measure the acceleration of the trunk, and inertial sensors may detect when a fall occurs, along with the causes of the fall.
“Body-worn gyroscopes measuring angular velocity, sensors to measure the acceleration of the trunk, and inertial sensors may detect when a fall occurs, along with the causes of the fall (276–279).”
From The Multidisciplinary Approach to Alzheimer’s Disease and Dementia. A Narrative Review of Non-Pharmacological Treatment (2018) · cites this paper as [277]
Cites
“Stops walking when talking” as a predictor of falls in elderly people
Lundin‐Olsson, L., Nyberg, L., & Gustafson, Y. (1997) · The Lancet · doi:10.1016/s0140-6736(97)24009-2 · Cited by 960 · see citing works
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 828 · see citing works
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P. F., & Robert, P. A. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 816 · see citing works
Najafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Büla, C., & Robert, P. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812189 · Cited by 760 · see citing works
Center of mass velocity-position predictions for balance control
Pai, Y., & Patton, J. L. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00165-0 · Cited by 758 · see citing works
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 658 · see citing works
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655 · see citing works
Pfeifer, M. A., Begerow, B., Minne, H. W., Abrams, C., Nachtigall, D., & Hansen, C. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.6.1113 · Cited by 591 · see citing works
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · see citing works
Najafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800763 · Cited by 435 · see citing works
Trunk Sway Measures of Postural Stability During Clinical Balance Tests: Effects of Age
Gill, J., Allum, J. H. J., Carpenter, M. G., Held‐Ziółkowska, M., Adkin, A. L., Honegger, F., & Pierchała, K. (2001) · The Journals of Gerontology Series A · doi:10.1093/gerona/56.7.m438 · Cited by 323 · see citing works
Self-citationAssessment of spatio-temporal parameters during unconstrained walking
Zijlstra, W. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1041-5 · Cited by 296 · see citing works
Jeka, J. J., Kiemel, T., Creath, R. A., et al. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00983.2003 · Cited by 295 · see citing works
Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 282 · see citing works
Trunk accelerometry as a measure of balance control during quiet standing
Moe‐Nilssen, R., & Helbostad, J. L. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00200-4 · Cited by 270 · see citing works
Standing balance evaluation using a triaxial accelerometer
Mayagoitia, R. E., Lötters, J. C., Veltink, P. H., & Hermens, H. J. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00199-0 · Cited by 249 · see citing works
Allum, J. H. J., Adkin, A. L., Carpenter, M. G., Held‐Ziółkowska, M., Honegger, F., & Pierchała, K. (2001) · Gait & Posture · doi:10.1016/s0966-6362(01)00132-1 · Cited by 182 · see citing works
Self-citationThe effect of gait speed on lateral balance control during walking in healthy elderly
Helbostad, J. L., & Moe‐Nilssen, R. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00197-2 · Cited by 168 · see citing works
Detecting Balance Deficits in Frequent Fallers Using Clinical and Quantitative Evaluation Tools
Cho, C., & Kamen, G. (1998) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1998.tb02461.x · Cited by 138 · see citing works
AGE‐RELATED DECLINE OF GAIT CONTROL UNDER A DUAL‐TASK CONDITION
Beauchet, O., Kressig, R. W., Najafi, B., Aminian, K., Dubost, V., & Mourey, F. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51385.x · Cited by 133 · see citing works
Allum, J. H. J., & Adkin, A. L. (2003) · Audiology and Neurotology · doi:10.1159/000071999 · Cited by 118 · see citing works
Self-citationSjöström, H., Allum, J. H. J., Carpenter, M. G., Adkin, A. L., Honegger, F., & Ettlin, T. M. (2003) · Spine · doi:10.1097/01.brs.0000083170.34304.a3 · Cited by 106 · see citing works
Self-citationde Hoon, E. W., Allum, J. H. J., Carpenter, M. G., et al. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04951-1 · Cited by 101 · see citing works
Self-citationParaschiv-Ionescu, A., Buchser, E., Rutschmann, B., et al. (2003) · Gait & Posture · doi:10.1016/j.gaitpost.2003.07.005 · Cited by 99 · see citing works
Clinical assessment of postural stability.
Weber, P. C., & Cass, S. P. (1993) · PubMed · Cited by 82 · see citing works
Vestibular prostheses: The engineering and biomedical issues
Wall, C., Merfeld, D. M., RAUCH, S., et al. (2003) · Journal of Vestibular Research · doi:10.3233/ves-2003-122-305 · Cited by 69 · see citing works
Elevated heels and adaptation to new shoes in frail elderly women
Lindemann, U., Scheible, S., Sturm, E., et al. (2003) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-003-0133-x · Cited by 32 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489 · see citing works
Zucchella, C., Sinforiani, E., Tamburin, S., Federico, A., Mantovani, E., Bernini, S., Casale, R., & Bartolo, M. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.01058 · Cited by 297 · see citing works
- Authors
- Allum, J. H., & Carpenter, M. G.
- Affiliations
- University Hospital of Basel (CH)
- Corresponding author
- Allum, John HJ
- Venue
- Current Opinion in Neurology
- Published
- 2005-02
- Volume
- 18
- Issue
- 1
- Pages
- 15-21
- ISSN
- 1350-7540 (ISSN-L)
- OpenAlex
- W2052215988
- Cited by
- 133
- References
- 27
- Citations by year
- 2025: 5 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 5 · 2018: 4 · 2017: 9 · 2016: 6 · 2015: 5 · 2014: 8 · 2013: 11 · 2012: 17
- FWCI
- 21.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Opinion in Neurology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- balance assessment, gait analysis, angular velocity sensor, gyroscope, wearable sensors, fall risk detection, balance rehabilitation, biofeedback, trunk acceleration, balance disorders, falls in older adults, ambulatory monitoring
- MeSH terms
- Acceleration, Accidental Falls, Aged, Biofeedback, Psychology, Postural Balance, Gait, Humans, Posture, Proprioception
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review