Blood pressure measurement in research and in clinical practice: recent evidence
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: For over a century the technique of blood pressure measurement developed by Riva-Rocci and Korotkoff has provided most of the data on hypertension diagnosis and treatment. Its limitations, however, are becoming increasingly evident and therefore alternative solutions are under investigation. This paper is intended to provide an overview of important recent progress in this field, and to highlight future perspectives. RECENT FINDINGS: A major development in blood pressure measurement is the technical improvement of electronic manometers for use either in the clinic (with the auscultatory approach, as an alternative to use of mercury columns), or in automated oscillometric devices yielding blood pressure measurements devoid of observer-dependency, and allowing long-term blood pressure monitoring. In the latter case, blood pressure measurement is made possible in settings other than the physician's office, either through ambulatory blood pressure monitoring or through self blood pressure measurement at home. These methods are growing in clinical importance, but further studies are needed to define their indications more precisely in the clinical evaluation of hypertensive patients. Recently, important steps towards better standards of blood pressure measurement have been taken, as summarized in the guidelines jointly issued by the European Society of Hypertension (ESH) and the European Society of Cardiology (ESC), in the 7th Joint National Committee Report and (in even more detail) in the Blood Pressure Measurement Guidelines published by the ESH Working Group on Blood Pressure Monitoring. SUMMARY: Blood pressure measurement is a rapidly developing field, the importance of which is increasingly acknowledged in the light of the growing awareness of the impact of hypertension on public health. Despite remarkable progress, many methodological issues still remain to be properly addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Kario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Self blood pressure monitoring at home by wrist devices: a reliable approach?
Parati, G., Asmar, R., & Stergiou, G. S. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00005 · Cited by 53
Self-citationHome or self blood pressure measurement? What is the correct term?
Stergiou, G. S., Efstathiou, S. P., Alamara, C. V., Mastorantonakis, S. E., & Roussias, L. G. (2003) · Journal of Hypertension · doi:10.1097/00004872-200312000-00013 · Cited by 45
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationFlynn, J. T., Mitsnefes, M., Pierce, C., Cole, S. R., Parekh, R. S., Furth, S. L., & Warady, B. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.110635 · Cited by 311
Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115
“Because of the frequent need for prolonged monitoring of blood pressure among critically ill patients, automated oscillometric NIBP measurements are commonly used in the ICU [3,4].”
MethodInfluentialRecommendations for blood pressure measuring devices for office/clinic use in low resource settings
Parati, G., Mendis, S., Abegunde, D., Asmar, R., Mieke, S., Murray, A., Shengelia, B., Steenvoorden, G., Van Montfrans, G., & O??Brien, E. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200502000-00002 · Cited by 60
“Although the auscultatory technique has remained essentially unchanged for over a century, there is now widespread acknowledgement that it is an inherently inaccurate method [4, 16 ,17].”
MethodSelf-citation
Metadata
- Authors
- Parati, G., Bilo, G., & Mancia, G.
- Venue
- Current Opinion in Nephrology and Hypertension
- Published
- 2004-05
- Volume
- 13
- Issue
- 3
- Pages
- 343-357
- ISSN
- 1062-4821 (ISSN-L)
- OpenAlex
- W1983533286
- Cited by
- 75
- References
- 6
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood pressure measurement in research and in clinical practice: recent evidence. https://app.cochat.ai/papers/10.1097/00041552-200405000-00013
- The paper
- Parati, G., Bilo, G., & Mancia, G. (2004). Blood pressure measurement in research and in clinical practice: recent evidence. Current Opinion in Nephrology and Hypertension. https://doi.org/10.1097/00041552-200405000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.