Influence of Diurnal Variation on the Intraocular Pressure Measurement of Treated Primary Open-Angle Glaucoma During Office Hours
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: Intraocular pressure has been shown in past studies to vary diurnally. The purpose of this study was to establish whether patients treated with timolol maleate for primary open-angle glaucoma should be reviewed at a specific time of day, within normal clinical hours (9 a.m. to 5 p.m.). It is normal practice to schedule review appointments into either morning or afternoon clinic sessions. This may result in abnormally high intraocular pressure values being missed. METHODS: The intraocular pressure of 28 people with primary open-angle glaucoma was measured by means of a Goldmann applanator on an hourly basis between the hours of 9 a.m. and 5 p.m. All subjects continued their antiglaucoma therapy of timolol maleate throughout the measurement period. RESULTS: The intraocular pressure increased significantly (p = 0.0008) throughout the measurement period, with maximal intraocular pressure values occurring at 5 p.m. in the afternoon. CONCLUSION: Although monitoring intraocular pressure values should not be the only consideration in glaucoma management, undetected rises in pressure may precede the development of optic disc cupping or visual field loss. The variability of intraocular pressure values has important implications in the scheduling of glaucoma intraocular pressure review measurements for the purposes of continuing treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
“Numerous recent prospective and retrospective articles (Rota-Bartelink et al. 1996; Graham & Drance 1999; Pointer 1999; Asrani et al. 2000; Liu 2001; Wax et al. 2002; Hughes et al. 2003; Denis 2004; Wilensky 2004; Blaise & Guillaume 2005; Barkana et al. 2006) have pointed out that 24-hr IOP…”
BackgroundBarkana, Y. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.6.793 · Cited by 278
First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244
Laukhin, V., Sánchez, I., Moya, A., Laukhina, E., Martin, R., Ussa, F., Rovira, C., Guimera, A., Villa, R., Aguiló, J., et al. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.05.021 · Cited by 57
Metadata
- Authors
- Rota-Bartelink, A. M., Pitt, A., & Story, I.
- Venue
- Journal of Glaucoma
- Published
- 1996-12
- Volume
- 5
- Issue
- 6
- Pages
- 410???415
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2051231120
- Cited by
- 35
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Diurnal Variation on the Intraocular Pressure Measurement of Treated Primary Open-Angle Glaucoma During Office Hours. https://app.cochat.ai/papers/10.1097/00061198-199612000-00009
- The paper
- Rota-Bartelink, A. M., Pitt, A., & Story, I. (1996). Influence of Diurnal Variation on the Intraocular Pressure Measurement of Treated Primary Open-Angle Glaucoma During Office Hours. Journal of Glaucoma. https://doi.org/10.1097/00061198-199612000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.