The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With Glaucoma
Abstract
OBJECTIVE: To determine whether intraocular pressure (IOP) monitoring outside of normal office hours adds clinically useful information. METHODS: We reviewed the records of all patients with glaucoma who were admitted for 24-hour IOP monitoring during 3 years. Applanation IOP was recorded in the sitting position from 7 am until midnight and in the supine position at 6 am. RESULTS: Thirty-two patients (22 women and 10 men) were enrolled (mean +/- SD age, 67.3 +/- 12.1 years). Mean +/- SD 24-hour IOP was 13.0 +/- 2.2 mm Hg. Mean +/- SD peak 24-hour IOP (16.8 +/- 3.2 mm Hg) was significantly higher than peak office IOP (14.7 +/- 3.2 mm Hg) (P<.001). Peak IOP was recorded outside of office hours in at least 1 eye in 22 patients (69%). Mean IOP fluctuation during 24-hour monitoring (6.9 +/- 2.9 mm Hg) was significantly greater than that during office hours (3.8 +/- 2.3 mm Hg) (P<.001). Peak 24-hour IOP was higher than the peak IOP noted during previous office visits in 40 eyes (62%). Results of 24-hour IOP monitoring led to immediate treatment change in 23 eyes (36%). CONCLUSIONS: In glaucoma patients with advanced disease or progression that are disproportionate to known IOP measurements, 24-hour monitoring of IOP may reveal a greater role for pressure-related risk for glaucoma progression than previously suspected and may alter treatment strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Factors for Glaucoma Progression and the Effect of Treatment: The Early Manifest Glaucoma Trial
Leske, M. C. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.1.48 · Cited by 2,030
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 901
Nouri-Mahdavi, K., Hoffman, D., Coleman, A. L., Liu, G., Li, G., Gaasterland, D., & Caprioli, J. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.017 · Cited by 704
Twenty-four-Hour Intraocular Pressure Pattern Associated with Early Glaucomatous Changes
Liu, J. H. K., Zhang, X., Kripke, D. F., & Weinreb, R. N. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0666 · Cited by 444
Compliance with Topical Pilocarpine Treatment
Kass, M. A., Meltzer, D. W., Gordon, M., Cooper, D., & Goldberg, J. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90939-6 · Cited by 341
Twenty-four-hour pattern of intraocular pressure in the aging population.
Liu, J. H., Kripke, D. F., Twa, M. D., Hoffman, R. E., Mansberger, S. L., Rex, K. M., Girkin, C. A., & Weinreb, R. N. (1999) · PubMed · Cited by 293
Nocturnal elevation of intraocular pressure in young adults.
Liu, J. H., Kripke, D. F., Hoffman, R. E., Twa, M. D., Loving, R. T., Rex, K. M., Gupta, N., & Weinreb, R. N. (1998) · PubMed · Cited by 285
Cited by
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
Normal-tension glaucoma: is it different from primary open-angle glaucoma?
Shields, M. B. (2008) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e3282f3919b · Cited by 255
Fogagnolo, P., Orzalesi, N., Ferreras, A., & Rossetti, L. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2889 · Cited by 75
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Metadata
- Authors
- Barkana, Y.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2006-06-01
- Volume
- 124
- Issue
- 6
- Pages
- 793
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2098477882
- Cited by
- 278
- References
- 27
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With Glaucoma. https://app.cochat.ai/papers/10.1001/archopht.124.6.793
- The paper
- Barkana, Y. (2006). Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With Glaucoma. Archives of Ophthalmology. https://doi.org/10.1001/archopht.124.6.793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.