Oscillometric blood pressure measurement: progress and problems

van Montfrans, Gert A.·2001·Blood Pressure Monitoring

Abstract

Oscillometric blood pressure measurement has become very popular, but although a number of devices have now passed both the Association for the Advancement of Medical Instrumentation and British Hypertension Society criteria, complacency with the state of the technique is as yet premature. In individual subjects, a substantial number of readings may deviate more than a clinically relevant 5 mmHg in devices that have earned a British Hypertension Society grade A rating. The marketing of pressure-wave-simulating devices is a welcome development as monitors can now be tested for reproducibility; an intra-device standard deviation of less than 2 mmHg has been proposed as the limit. Authors suggest that these simulators are currently better suited to intra- than between-device testing since they are not yet fully confident that the simulated waveforms are indistinguishable from the man-made pressure waves. Simulators should, however, be incorporated into our standard validation protocols in order eventually to obviate the human, fallible, factor in the validation protocols. The currently employed maximal amplitude algorithm has many drawbacks as the parameter identification points for systolic and diastolic pressure depend on many factors, for example pulse pressure, heart rate and arterial stiffness. These errors have now been demonstrated in clinical studies. Modern pattern recognition algorithms are being constructed but have not yet produced convincing results. As repeatedly stated, the development of a more robust and more widely applicable algorithm than the maximal amplitude approach should be allocated a high priority.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200112000-00004

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 175

Metadata

Authors
van Montfrans, G. A.
Venue
Blood Pressure Monitoring
Published
2001-12
Volume
6
Issue
6
Pages
287-290
ISSN
1359-5237 (ISSN-L)
OpenAlex
W85997425
Cited by
175
References
5
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oscillometric blood pressure measurement: progress and problems. https://app.cochat.ai/papers/10.1097/00126097-200112000-00004
The paper
van Montfrans, G. A. (2001). Oscillometric blood pressure measurement: progress and problems. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200112000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.