Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time

Kachuee, Mohamad, Kiani, Mohammad Mahdi, Mohammadzade, Hoda, Shabany, Mahdi·2015·2015 IEEE International Symposium on Circuits and Systems (ISCAS)

Abstract

Recently a few methods have been proposed in the literature for non-invasive cuff-less estimation of systolic and diastolic blood pressures. One of the most prominent methods is to use the Pulse Transit Time (PTT). Although it is proven that PTT has a strong correlation with the systolic and diastolic blood pressures, this relation is highly dependent to each individuals physiological properties. Therefore, it requires per person calibration for accurate and reliable blood pressure estimation from PTT, which is a big drawback. To alleviate this issue, in this paper, a novel method is proposed for accurate and reliable estimation of blood pressure that is calibration-free. This goal is accomplished by extraction of several physiological parameters from Photoplethysmography (PPG) signal as well as utilizing signal processing and machine learning algorithms. The results show that the accuracy of the proposed method achieves grade B for the estimation of the diastolic blood pressure and grade C for the estimation of the mean arterial pressure under the standard British Hypertension Society (BHS) protocol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iscas.2015.7168806

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 333

Metadata

Authors
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M.
Venue
2015 IEEE International Symposium on Circuits and Systems (ISCAS)
Publisher
IEEE
Published
2015-05
Pages
1006-1009
ISSN
0271-4302 (ISSN-L)
OpenAlex
W1528687555
Cited by
333
References
9
FWCI
23.58
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. https://app.cochat.ai/papers/10.1109/iscas.2015.7168806
The paper
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2015). Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. 2015 IEEE International Symposium on Circuits and Systems (ISCAS). https://doi.org/10.1109/iscas.2015.7168806

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.