The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
Abstract
Recently a few methods have been proposed in the literature for non-invasive cuff-less estimation of systolic and diastolic blood pressures. One of the most prominent methods is to use the Pulse Transit Time (PTT). Although it is proven that PTT has a strong correlation with the systolic and diastolic blood pressures, this relation is highly dependent to each individuals physiological properties. Therefore, it requires per person calibration for accurate and reliable blood pressure estimation from PTT, which is a big drawback. To alleviate this issue, in this paper, a novel method is proposed for accurate and reliable estimation of blood pressure that is calibration-free. This goal is accomplished by extraction of several physiological parameters from Photoplethysmography (PPG) signal as well as utilizing signal processing and machine learning algorithms. The results show that the accuracy of the proposed method achieves grade B for the estimation of the diastolic blood pressure and grade C for the estimation of the mean arterial pressure under the standard British Hypertension Society (BHS) protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Blood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E., Waeber, B., Parati, G., Staessen, J., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 903
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
Oscillometric blood pressure measurement: progress and problems
van Montfrans, G. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00004 · Cited by 175
Pulse transit time: Relationship to blood pressure
Obrist, P. A., Light, K. C., McCubbin, J. A., Hutcheson, J. S., & Hoffer, J. L. (1978) · Behavior Research Methods · doi:10.3758/bf03205360 · Cited by 41
Cited by
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Self-citationFlexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 294
PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133
Metadata
- Authors
- Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M.
- Venue
- 2015 IEEE International Symposium on Circuits and Systems (ISCAS)
- Publisher
- IEEE
- Published
- 2015-05
- Pages
- 1006-1009
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W1528687555
- Cited by
- 333
- References
- 9
- FWCI
- 23.58
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. https://app.cochat.ai/papers/10.1109/iscas.2015.7168806
- The paper
- Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2015). Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. 2015 IEEE International Symposium on Circuits and Systems (ISCAS). https://doi.org/10.1109/iscas.2015.7168806
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.