Oscillometric blood pressure measurement: progress and problems
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Oscillometric blood pressure measurement has become very popular, but although a number of devices have now passed both the Association for the Advancement of Medical Instrumentation and British Hypertension Society criteria, complacency with the state of the technique is as yet premature. In individual subjects, a substantial number of readings may deviate more than a clinically relevant 5 mmHg in devices that have earned a British Hypertension Society grade A rating. The marketing of pressure-wave-simulating devices is a welcome development as monitors can now be tested for reproducibility; an intra-device standard deviation of less than 2 mmHg has been proposed as the limit. Authors suggest that these simulators are currently better suited to intra- than between-device testing since they are not yet fully confident that the simulated waveforms are indistinguishable from the man-made pressure waves. Simulators should, however, be incorporated into our standard validation protocols in order eventually to obviate the human, fallible, factor in the validation protocols. The currently employed maximal amplitude algorithm has many drawbacks as the parameter identification points for systolic and diastolic pressure depend on many factors, for example pulse pressure, heart rate and arterial stiffness. These errors have now been demonstrated in clinical studies. Modern pattern recognition algorithms are being constructed but have not yet produced convincing results. As repeatedly stated, the development of a more robust and more widely applicable algorithm than the maximal amplitude approach should be allocated a high priority.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E. (2000) · BMJ · doi:10.1136/bmj.320.7242.1128 · Cited by 452
van der Heijden-Spek, J. J., Staessen, J. A., Fagard, R. H., Hoeks, A. P., Boudier, H. A. S., & Van Bortel, L. M. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.637 · Cited by 388
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287
van Popele, N. M., Bos, W. J. W., de Beer, N. A. M., van der Kuip, D. A. M., Hofman, A., Grobbee, D. E., & Witteman, J. C. M. (2000) · Hypertension · doi:10.1161/01.hyp.36.4.484 · Cited by 170
Blood pressure monitoring: Automated oscillometric devices
Ramsey, M. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01617900 · Cited by 155
Baker, P. D., Westenskow, D. R., & Kück, K. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02530049 · Cited by 154
A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring
Staessen, J. A., Fagard, R., Thijs, L., & Amery, A. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.912 · Cited by 119
Comparative accuracy of six ambulatory devices according to blood pressure levels
Brien, E. O., Atkins, N., Mee, F., & O??Malley, K. (1993) · Journal of Hypertension · doi:10.1097/00004872-199306000-00012 · Cited by 63
van Ittersum, F. J., Wijering, R. M. J., Lambert, J., Donker, A. J. M., & Stehouwer, C. D. A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816080-00007 · Cited by 52
The relative accuracies of two automated noninvasive arterial pressure measurement devices
Gorback, M. S., Quill, T. J., & Lavine, M. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01617893 · Cited by 52
Narus, S. P., Egbert, T. P., Lee, T.-K., Lu, J. Z., & Westenskow, D. R. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01616986 · Cited by 35
Jn, A., & Dh, S. (2000) · PubMed · Cited by 30
Ursino, M., & Cristalli, C. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2792259 · Cited by 29
Goonasekera, C. D. A. (1998) · Blood Pressure · doi:10.1080/080370598437268 · Cited by 20
Standard algorithm for blood pressure measurement by sphygmo-oscillographic method
Sapiński, A. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02637026 · Cited by 16
Amoore, J., Geake, W. B., & Scott, D. H. T. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534143 · Cited by 14
A simulation-based evaluation of nine oscillometric blood pressure monitors for self-measurement
Ng, K.-G. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200010000-00008 · Cited by 7
Indirect Measurement of Eye-Level Arterial Pressure by the Volume Oscillometric Method
Kobayashi, H., Shimazu, H., KAWARADA, A., Ito, H., & Mizumoto, C. (1990) · Journal of Clinical Engineering · doi:10.1097/00004669-199005000-00007 · Cited by 5
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Aboyans, V., Criqui, M. H., Abraham, P., Allison, M. A., Creager, M. A., Diehm, C., Fowkes, F. G. R., Hiatt, W. R., Jönsson, B., Lacroix, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276fbcb · Cited by 1,703
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J. W., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · The Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2005.04377.x · Cited by 436
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2015) · 2015 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2015.7168806 · Cited by 333
Metadata
- Authors
- van Montfrans, G. A.
- Venue
- Blood Pressure Monitoring
- Published
- 2001-12
- Volume
- 6
- Issue
- 6
- Pages
- 287-290
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W85997425
- Cited by
- 175
- References
- 19
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.