Abstract
Background: The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. Methods: Forty consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a Macintosh (n = 20) or Airtraq (n = 20) laryngoscope. All patients were intubated by one of four anesthesiologists experienced in the use of both laryngoscopes. Results: No significant differences in demographic or airway variables were observed between the groups. All but one patient, in the Macintosh group, were successfully intubated on the first attempt. The Airtraq reduced the duration of intubation attempts (mean ± SD: 13.2 ± 5.5 vs. 20.3 ± 12.2 s), the need for additional maneuvers, and the intubation difficulty scale score (0.1 ± 0.5 vs. 2.7 ± 2.5). Tracheal intubation with the Airtraq caused fewer alterations in blood pressure and heart rate. Conclusions: These findings demonstrate the utility of the Airtraq laryngoscope for tracheal intubation in patients with cervical spine immobilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new variant of Creutzfeldt-Jakob disease in the UK
Will, R. G., Ironside, J. W., Zeidler, M., Estibeiro, K., Cousens, S. N., Smith, P. G., Alperovitch, A., Poser, S., Pocchiari, M., & Hofman, A. (1996) · The Lancet · doi:10.1016/s0140-6736(96)91412-9 · Cited by 2,707 · cited 1×
“transmission of prions, which are thought to be responsible for causing variant Creutzfeldt–Jakob disease.(25,26)”
BackgroundDifficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471 · cited 1×
“Additional endpoints included the number of intubation attempts and the number of optimization maneuvers required (use of a bougie, BURP, second assistant) to aid tracheal intubation, and the Cormack and Lehane grade at laryngoscopy.(19)”
MethodAdverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995 · cited 1×
“Failure to successfully intubate the trachea and secure the airway remains a leading cause of morbidity and mortality, in the operative and emergency settings.(11,12) The Airtraq (Prodol Ltd.”
BackgroundManagement of the Difficult Airway: A Closed Claims Analysis
Peterson, G. N., Domino, K. B., Caplan, R. A., Posner, K. L., Lee, L. A., & Cheney, F. W. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00009 · Cited by 852
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703 · cited 2×
“The primary endpoints were the duration of the tracheal intubation procedure and the IDS score.(18) The duration of the intubation attempt was defined as the time taken from insertion of the blade between the teeth until the ETT was placed through the vocal cords, as evidenced by visual confirmation by the anesthesiol…”
BackgroundMethodCheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199908000-00030 · Cited by 329
Nolan, J. P., & Wilson, M. E. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb07133.x · Cited by 271 · cited 1×
“immobilization are consistently poorer, compared with nonimmobilized controls.(5,6) MIAS prevents head exten-”
BackgroundThe effect on laryngoscopy of different cervical spine immobilization techniques
HEATH, K. J. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb04254.x · Cited by 236 · cited 1×
“decreased interincisor distance and cervical spine immobility.(7) The adequacy of the laryngeal view obtained is a major factor in determining the difficulty of intubation.”
BackgroundLennarson, P. J., Smith, D. W., Sawin, P. D., Todd, M. M., Sato, Y., & Traynelis, V. C. (2001) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2001.94.2.0265 · Cited by 156 · cited 1×
“In anatomical studies, after complete C4–C5 ligamentous injury, MIAS did reduce segmental angular rotation and distraction, although it did increase subluxation, compared with nonimmobilization.(3) In a case series of 150 patients with traumatic cervical spine injuries with well-preserved neurologic”
ResultAgrò, F. E., Barzoi, G., & Montecchia, F. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg560 · Cited by 153
Neurologic Deterioration Associated with Airway Management in a Cervical Spine-injured Patient
Hastings, R. H., & Kelley, S. D. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00022 · Cited by 147 · cited 2×
“FAILURE to adequately immobilize the neck during tracheal intubation in patients with cervical spine injuries can result in a devastating neurologic outcome.(1) A widely used approach to neck immobilization during tracheal intubation is manual in-line axial stabilization (MIAS).”
BackgroundMethodElective oral tracheal intubation in cervical spine-injured adults
Suderman, V. S., Crosby, E. T., & Lui, A. C. P. (1991) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03008461 · Cited by 112 · cited 3×
“the patient awake, did not result in any neurologic complications.(4) It is therefore an accepted practice in many”
BackgroundInfluentialMort, T. C. (2005) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2005.02.004 · Cited by 95 · cited 1×
“Failure to successfully intubate the trachea and secure the airway remains a leading cause of morbidity and mortality, in the operative and emergency settings.(11,12) The Airtraq (Prodol Ltd.”
BackgroundSmith, C. E., Pinchak, A. B., Sidhu, T. S., Radesic, B. P., Pinchak, A. C., & Hagen, J. F. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00015 · Cited by 75 · cited 3×
“, Burnaby, BC, Canada),(31) and WuScope (Pentax Precision Instruments, Orangeburg, NY).(6) Further comparative studies are needed to determine the relative efficacies of these devices.”
BackgroundCosan, T. E., Gücüyener, D., Dündar, E., Arslantas, A., Vural, M., Uzuner, K., & Tel, E. (2001) · Journal of neurosurgery · doi:10.3171/jns.2001.94.2.0265 · Cited by 60
Hirsch, N. P., Beckett, A. A. J., Collinge, J., Scaravilli, F., Tabrizi, S. J., & Berry, S. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04221.x · Cited by 54 · cited 1×
“reusable laryngoscope blades during cleaning and sterilization.(27,28) In recognition of these concerns, the guide-”
BackgroundKihara, S., Yaguchi, Y., Taguchi, N., Brimacombe, J. R., & Watanabe, S. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018590 · Cited by 31 · cited 1×
“Previous studies have used this model of simulated cervical spine to assess optimal intubation technique in similar patient populations.(20,21) All intubations in this study were performed by one of four experienced anesthesiologists in patients deemed on clinical assessment to be at low risk for difficult tracheal in…”
MethodGeneral Anesthesia: Management Considerations in the Trauma Patient
Stene, J. K., & Grande, C. M. (1990) · Critical Care Clinics · doi:10.1016/s0749-0704(18)30392-0 · Cited by 29
Cited by
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Video‐laryngoscopes in the adult airway management: a topical review of the literature
NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02285.x · Cited by 316
Malik, M. A., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen231 · Cited by 229
Self-citationKleine-Brueggeney, M., Greif, R., Schoettker, P., Savoldelli, G. L., Nabecker, S., & Theiler, L. G. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew058 · Cited by 216
“(25th; 75th percentile) [range]} 56 (45; 85) [20–177] 60 (48; 98) [17–180] 53 (42; 77) [20–179] 47 (36; 60) [18–175] 93 (54; 144) [33–180] 59 (46; 78) [31–180] <0.”
InfluentialMaharaj, C. H., Costello, J. F., Harte, B. H., & Laffey, J. G. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05316.x · Cited by 186
Self-citation
Metadata
- Authors
- Maharaj, C. H., Buckley, E., Harte, B. H., & Laffey, J. G.
- Venue
- Anesthesiology
- Published
- 2007-07
- Volume
- 107
- Issue
- 1
- Pages
- 53-59
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2126452543
- Cited by
- 192
- References
- 19
- FWCI
- 26.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.