CoChat

Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients

Bur, Andreas, Herkner, Harald, Vlcek, Marianne, Woisetschläger, Christian, Derhaschnig, Ulla, Delle Karth, Georg, Laggner, Anton N., Hirschl, Michael M. · 2003 · Critical Care Medicine
Cited by 123

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Comparison of oscillometric blood pressure measurement with two different devices (M3000A using a new algorithm and M1008A using an established algorithm, both Hewlett Packard) and evaluation of current recommendations concerning the relation between cuff size and upper arm circumference in critically ill patients. DESIGN: Prospective data collection. SETTING: Emergency department in a 2000-bed inner-city hospital. PATIENTS: A total of 30 patients categorized into three groups according to their upper arm circumference (I, 18-25 cm; II, 25.1-33 cm; III, 33.1-47.5 cm) were enrolled in the study protocol. INTERVENTIONS In each patient, two noninvasive blood pressure devices with three different cuff sizes were used to perform oscillometric blood pressure measurement. Invasive mean arterial blood pressure measurement was done by cannulation of the radial artery. MEASUREMENT AND MAIN RESULTS: Overall, 1,011 pairs of simultaneous oscillometric and invasive blood pressure measurements were collected in 30 patients (group I, n = 10; group II, n = 10; group III, n = 10). The overall discrepancy between both methods with the M3000A was -2.4 +/- 11.8 mm Hg (p <.0001) and, with the M1008A, -5.3 +/- 11.6 mm Hg (p <.0001) if the recommended cuff size according to the upper arm circumference was used (352 measurements). If smaller cuff sizes than recommended were used (308 measurements performed in group II and III), the overall discrepancy between both methods with the M3000A was 1.3 +/- 13.4 mm Hg (p <.024) and, with the M1008A, -2.3 +/- 11.5 mm Hg (p <.0001). CONCLUSION: The new algorithm reduced the overall bias of the oscillometric method but still showed a significant discrepancy between both methods of blood pressure measurement, primarily due to the mismatch between upper arm circumference and cuff size. The improvement of the algorithm alone could not result in a sufficient improvement of oscillometric blood pressure measurement. A reevaluation of the recommendations concerning the relation between upper arm circumference and cuff size are urgently required if oscillometric blood pressure measurement should become a reasonable alternative to intra-arterial blood pressure measurement in critically ill patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000053650.12025.1a

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 123

Metadata

Authors
Bur, A., Herkner, H., Vlcek, M., Woisetschläger, C., Derhaschnig, U., Delle Karth, G., Laggner, A. N., & Hirschl, M. M.
Venue
Critical Care Medicine
Published
2003-03
Volume
31
Issue
3
Pages
793-799
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1969276775
Cited by
123
References
4
FWCI
3.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients. https://app.cochat.ai/papers/10.1097/01.ccm.0000053650.12025.1a
The paper
Bur, A., Herkner, H., Vlcek, M., Woisetschläger, C., Derhaschnig, U., Delle Karth, G., Laggner, A. N., & Hirschl, M. M. (2003). Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000053650.12025.1a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.