CoChat

Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The Third Sonography Outcomes Assessment Program (SOAP-3) Trial*

Milling, Truman J., Rose, John, Briggs, William M., Birkhahn, Robert, Gaeta, Theodore J., Bove, Joseph J., Melniker, Lawrence A. · 2005 · Critical Care Medicine
Cited by 334

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

CONTEXT: A 2001 Agency for Healthcare Research and Quality Evidence Report on patient safety addressed point-of-care limited ultrasonography guidance for central venous cannulation and strongly recommended real-time, dynamic guidance for all central cannulas. However, on the basis of one limited study, the report dismissed static assistance, a "quick look" with ultrasound to confirm vein location before preparing the sterile field, as unhelpful. OBJECTIVE: The objective of this trial was to compare the overall success rate of central cannula placement with use of dynamic ultrasound (D), static ultrasound (S), and anatomical landmarks (LM). DESIGN AND SETTING: A concealed, randomized, controlled, clinical trial conducted from September 2003 to February 2004 in a U.S. urban teaching hospital. PATIENTS: Two-hundred one patients undergoing internal jugular vein central venous cannulation. INTERVENTIONS: Patients were randomly assigned to three groups: 60 to D, 72 to S, and 69 to LM. An iLook25 SonoSite was used for all imaging. MEASUREMENTS AND MAIN RESULTS: Cannulation success, first-attempt success, and number of attempts were noted. Other measures were vein size and clarity of LM. Results, controlled for pretest difficulty assessment, are stated as odds improvement (95% confidence interval) over LM for D and S. D had an odds 53.5 (6.6-440) times higher for success than LM. S had an odds 3 (1.3-7) times higher for success than LM. The unadjusted success rates were 98%, 82%, and 64% for D, S, and LM. For first-attempt success, D had an odds 5.8 (2.7-13) times higher for first success than LM, and S had an odds 3.4 (1.6-7.2) times higher for first success than LM. The unadjusted first-attempt success rates were 62%, 50%, and 23% for D, S, and LM. CONCLUSIONS: Ultrasound assistance was superior to LM techniques. D outperformed S but may require more training and personnel. All central cannula placement should be conducted with ultrasound assistance. The 2001 Agency for Healthcare Research and Quality Evidence Report dismissing static assistance was incorrect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000171533.92856.e5

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A.
Venue
Critical Care Medicine
Published
2005-08
Volume
33
Issue
8
Pages
1764-1769
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1997383824
Cited by
334
References
18
FWCI
14.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.