Time-domain cross-correlation baroreflex sensitivity: performance on the EUROBAVAR data set
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To test a new method (cross-correlation baroreflex sensitivity, xBRS) for the computation of time-domain baroreflex sensitivity on spontaneous blood pressure and heart interval variability using the EUROBAVAR data set. METHODS: We applied xBRS to the 42 records in the EUROBAVAR data set, obtained from 21 patients in the lying and standing positions. One patient had a recent heart transplant and one was diabetic with evident cardiac autonomic neuropathy. xBRS computes the correlation between beat-to-beat systolic blood pressure and R-R interval, resampled at 1 Hz, in a sliding 10 s window, with delays of 0-5 s for interval. The delay with the greatest positive correlation is selected and, when significant at P = 0.01, slope and delay are recorded as one xBRS value. Each 1 s of the recording is the start of a new computation. Non-parametric tests are used. RESULTS: With patients in the lying position, xBRS yielded a value of 12.4 ms/mmHg compared with the EUROBAVAR sequential 16.2 ms/mmHg, and for the standing positions the respective values were 6.2 and 6.7 ms/mmHg, giving lying to standing ratios of 1.96 and 2.10, respectively. xBRS yielded results for all files, with 20 values per minute on average at a lower within-patient variance. Best delays were 0, 1 and 2 s, and the delay increased by 102 ms when the patient was in the standing position. The xBRS method was successful in the patients with diabetes and the heart transplant. CONCLUSION: The xBRS method should be considered for experimental and clinical use, because it yielded values that correlated strongly with and were close to the EUROBAVAR averages, yielded more values per minute, had lower within-patient variance and measured baroreflex delay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snedecor, G. W., & Cochran, W. G. (1967) · Cited by 6,573
SMYTH, H. S., SLEIGHT, P., & PICKERING, G. W. (1969) · Circulation Research · doi:10.1161/01.res.24.1.109 · Cited by 1,282
Hamming, R. W., & Stearns, S. D. (1977) · Cited by 1,275
Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model
deBoer, R. W., Karemaker, J. M., & Strackee, J. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.3.h680 · Cited by 851
Self-citationAssessment of baroreceptor reflex sensitivity by means of spectral analysis.
Robbe, H. W., Mulder, L. J., Rüddel, H., Langewitz, W. A., Veldman, J. B., & Mulder, G. (1987) · Hypertension · doi:10.1161/01.hyp.10.5.538 · Cited by 746
La Rovere, M. T., Specchia, G., Mortara, A., & Schwartz, P. J. (1988) · Circulation · doi:10.1161/01.cir.78.4.816 · Cited by 631
Eckberg, D. L. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.037192 · Cited by 431
Laude, D., Elghozi, J.-L., Girard, A., Bellard, E., Bouhaddi, M., Castiglioni, P., Cerutti, C., Cividjian, A., Di Rienzo, M., Fortrat, J.-O., et al. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00709.2002 · Cited by 402
Self-citationSpontaneous Cardiac Baroreflex in Humans: Comparison With Drug-Induced Responses
Parlow, J., Viale, J.-P., Annat, G., Hughson, R., & Quintin, L. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1058 · Cited by 392
Evaluation of baroreceptor reflex by blood pressure monitoring in unanesthetized cats
Bertinieri, G., DiRienzo, M., Cavallazzi, A., Ferrari, A. U., Pedotti, A., & Mancia, G. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.255.6.1-a · Cited by 300
Evaluation of baroreceptor reflex by blood pressure monitoring in unanesthetized cats
Bertinieri, G., Di Rienzo, M., Cavallazzi, A., Ferrari, A. U., Pedotti, A., & Mancia, G. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.2.h377 · Cited by 241
Time delays in the human baroreceptor reflex
Borst, C., & Karemaker, J. M. (1983) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(83)90004-8 · Cited by 153
Self-citationSteptoe, A., & Vogele, C. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.8.627 · Cited by 133
Modulation of carotid baroreflex responsiveness in man: effects of posture and propranolol
Eckberg, D. L., Abboud, F. M., & Mark, A. L. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.3.383 · Cited by 129
Bernardi, L., Valenti, C., Wdowczyk‐Szulc, J., Frey, A. W., Rinaldi, M., Spadacini, G., Passino, C., Martinelli, L., Viganò, M., & Finardi, G. (1998) · Circulation · doi:10.1161/01.cir.97.14.1368 · Cited by 88
Baroreflex sensitivity in the elderly: influence of age, breathing and spectral methods
GERRITSEN, J., TenVoorde, B. J., DEKKER, J. M., Kostense, P. J., Bouter, L. M., & Heethaar, R. M. (2000) · Clinical Science · doi:10.1042/cs0990371 · Cited by 69
Katsube, Y., Sato, H., Naka, M., Kim, B. H., Kinoshita, N., Koretsune, Y., & Hori, M. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00525-5 · Cited by 67
CASTIGLIONI, P., PARATI, G., OMBONI, S., MANCIA, G., IMHOLZ, B. P. M., WESSELING, K. H., & DI RIENZO, M. (1999) · Clinical Science · doi:10.1042/cs0970129 · Cited by 60
Self-citationContinuous cardiac baroreceptor measurement during tilt in healthy elderly subjects
Youde, J., Panerai, R. B., Gillies, C., & Potter, J. F. (2002) · Clinical Autonomic Research · doi:10.1007/s10286-002-0049-3 · Cited by 11
Cited by
Heart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820
“[137] have proposed a cross-correlation baro-flex sensitivity (xBRS) technique for the computation of time-domain baroreflex sensitivity on spontaneous BP and HRV using EUROBAVAR data set.”
MethodChildhood Obesity and Cardiovascular Dysfunction
Cote, A. T., Harris, K. C., Panagiotopoulos, C., Sandor, G. G. S., & Devlin, A. M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.042 · Cited by 454
Guzik, P., Piskorski, J., Krauze, T., Schneider, R., Wesseling, K. H., Wykretowicz, A., & Wysocki, H. (2007) · The Journal of Physiological Sciences · doi:10.2170/physiolsci.rp005506 · Cited by 232
“However, the cross-correlation method was shown to be reliable in persons with a wide range of BRS values and needs no interventions producing non physiological increases of blood pressure over a short time [25].”
MethodSelf-citationMattace-Raso, F. U., van den Meiracker, A. H., Bos, W. J., van der Cammen, T. J., Westerhof, B. E., Elias-Smale, S., Reneman, R. S., Hoeks, A. P., Hofman, A., & Witteman, J. C. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32811d6a07 · Cited by 202
Self-citationNeuroprosthetic baroreflex controls haemodynamics after spinal cord injury
Squair, J. W., Gautier, M., Mahe, L., Soriano, J. E., Rowald, A., Bichat, A., Cho, N., Anderson, M. A., James, N. D., Gandar, J., et al. (2021) · Nature · doi:10.1038/s41586-020-03180-w · Cited by 174
Metadata
- Authors
- Westerhof, B. E., Gisolf, J., Stok, W. J., Wesseling, K. H., & Karemaker, J. M.
- Venue
- Journal of Hypertension
- Published
- 2004-07
- Volume
- 22
- Issue
- 7
- Pages
- 1371-1380
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2153245171
- Cited by
- 258
- References
- 19
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.