Validation of the Omron 705 IT oscillometric device for home blood pressure measurement in children and adolescents: The Arsakion School Study
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Limited evidence exists on the accuracy of oscillometric devices for blood pressure measurement in children. This study validated the Omron 705 IT monitor (Omron Healthcare Europe BV, Hoofddorp, The Netherlands) in normotensive children and adolescents. METHODS: Simultaneous blood pressure measurements were taken by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements by using the tested device. Absolute device-observer blood pressure differences were classified into three zones (within 5, 10 and 15 mmHg) and assessed using the European Society of Hypertension International Protocol criteria. The number of readings with a difference within 5 mmHg was calculated for each individual. The American Association for the Advancement of Medical Instrumentation criterion (mean difference+ or -SD <5+ or -8 mmHg) was also applied. RESULTS: A total of 197 study participants (591 readings) were included (99 boys, mean age+ or -SD 10.6+ or -2.4 years (range 6-16 years). The device produced 378 (64%), 532 (90%) and 579 (98%) measurements within 5, 10 and 15 mmHg, respectively, for systolic blood pressure, and 415 (70%), 525 (89%) and 577 (98%) measurements, respectively, for diastolic blood pressure. In all, 136 study participants (69%) had at least two systolic blood pressure differences within 5 mmHg and 16 (8%) had no differences within 5 mmHg (for diastolic blood pressure 147 (75%) and nine (5%) participants, respectively). Mean systolic blood pressure difference was 4.0+ or -4.8 mmHg and diastolic blood pressure -2.1+ or -5.9 mmHg and was <5+ or -8 mmHg in quartiles of participants divided by age, height, body mass index, arm circumference, blood pressure or pulse rate. CONCLUSIONS: The Omron 705 IT appears to be an accurate device for blood pressure measurement in normotensive children and adolescents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National High Blood Pressure Education Program Working Group on High Blood Pressure in Children and Adolescents (2004) · PEDIATRICS · doi:10.1542/peds.114.2.s2.555 · Cited by 6,938
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationTrends in Blood Pressure Among Children and Adolescents
Muntner, P. (2004) · JAMA · doi:10.1001/jama.291.17.2107 · Cited by 884
OʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
El Assaad, M. A., Topouchian, J. A., & Asmar, R. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00006 · Cited by 224
Prevalence and consequence of systolic hypertension in children
SOROF, J. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02303-2 · Cited by 63
Reporting bias in self-measurement of blood pressure
Myers, M. G. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200108000-00003 · Cited by 57
Measurement of blood pressure at home: survey among pediatric nephrologists
Bald, M., & Hoyer, P. F. (2001) · Pediatric Nephrology · doi:10.1007/s004670100027 · Cited by 56
White-coat hypertension and masked hypertension in children
Stergiou, G. S., Yiannes, N. J., Rarra, V. C., & Alamara, C. V. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200512000-00002 · Cited by 55
Self-citationAccuracy of the SpaceLabs 90207 ambulatory blood pressure monitor in children and adolescents.
Belsha, C., Wells, T., Bowe Rice, H., Neaville, W., & Berry, P. (1996) · PubMed · Cited by 55
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationSmeets, T., Cornelisse, S., Quaedflieg, C. W. E. M., Meyer, T., Jelicic, M., & Merckelbach, H. (2012) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2012.04.012 · Cited by 376
“SBP and DBP were measured using an Omron 705IT (HEM-759-E; Omron Healthcare Europe BV, Hoofddorp, the Netherlands), a fully automated upper-arm oscillometric blood pressure monitoring device clinically validated by the Association for the Advancement of Medical Instruments, the European Society of Hypertension, and th…”
Reference Values of Pulse Wave Velocity in Healthy Children and Teenagers
Reusz, G. S., Cseprekal, O., Temmar, M., Kis, E., Cherif, A. B., Thaleb, A., Fekete, A., Szabó, A. J., Benetos, A., & Salvi, P. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.152686 · Cited by 302
ERICA: prevalences of hypertension and obesity in Brazilian adolescents
Bloch, K. V., Klein, C. H., Szklo, M., Kuschnir, M. C. C., Abreu, G. D. A., Barufaldi, L. A., Veiga, G. V. D., Schaan, B., Silva, T. L. N. D., Moraes, A. J. P., et al. (2016) · Revista de Saúde Pública · doi:10.1590/s01518-8787.2016050006685 · Cited by 266
Bloch, K. V., Szklo, M., Kuschnir, M. C. C., Abreu, G. D. A., Barufaldi, L. A., Klein, C. H., de Vasconcelos, M. T., da Veiga, G. V., Figueiredo, V. C., Dias, A., et al. (2015) · BMC Public Health · doi:10.1186/s12889-015-1442-x · Cited by 220
“This model has been validated for adolescents [24] and it has been chosen due to its ease of use and the minimization of observer bias or digit preference (which are the common errors associated with the auscultatory method) [25].”
MethodHome blood pressure normalcy in children and adolescents: the Arsakeion School study
Stergiou, G. S., Yiannes, N. G., Rarra, V. C., & Panagiotakos, D. B. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e328122d3fc · Cited by 119
Self-citationStergiou, G. S., Nasothimiou, E., Giovas, P., Kapoyiannis, A., & Vazeou, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328301c411 · Cited by 114
Self-citationStergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74
Self-citationAccuracy of Automated Blood Pressure Measurement in Children: Evidence, Issues, and Perspectives
Stergiou, G. S., Boubouchairopoulou, N., & Kollias, A. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08553 · Cited by 72
Self-citationResponse rate in the study of cardiovascular risks in adolescents–ERICA.
Silva, T. L. N. D., Klein, C. H., Souza, A. D. M., Barufaldi, L. A., Abreu, G. D. A., Kuschnir, M. C. C., Vasconcellos, M. T. L. D., & Bloch, K. V. (2016) · Revista de Saúde Pública · doi:10.1590/s01518-8787.2016050006730 · Cited by 63
Staessen, J. A., Thijs, L., Ohkubo, T., Kikuya, M., Richart, T., Boggia, J., Adiyaman, A., Dechering, D. G., Kuznetsova, T., Thien, T., et al. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283108f93 · Cited by 56
Home Blood Pressure Monitoring in Children: How Many Measurements are Needed?
Stergiou, G. S., Christodoulakis, G., Giovas, P., Lourida, P., Alamara, C., & Roussias, L. G. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.38 · Cited by 40
Self-citationStergiou, G. S., Karpettas, N., Panagiotakos, D. B., & Vazeou, A. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.59 · Cited by 36
Self-citationHome blood pressure normalcy in non-European adolescents
Jardim, T. V., de Souza Carneiro, C., Morais, P., Mendonça, K. L., Póvoa, T. I. R., Nascente, F. M., Roriz, V., Barroso, W. K. S., Sousa, A. L. L., & Jardim, P. C. V. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001495 · Cited by 20
“The use of a validated automated oscillometric device for home BP monitoring in adolescents [11] is one of the strengths of this study.”
MethodInfluentialMethodology and Applicability of Home Blood Pressure Monitoring in Children and Adolescents
Stergiou, G. S., & Ntineri, A. (2018) · Pediatric Hypertension · doi:10.1007/978-3-319-31107-4_45 · Cited by 7
Self-citationHome blood pressure monitoring in children, pregnancy, and chronic kidney disease
Kollias, A., Shennan, A., Agarwal, R., Ntineri, A., & Stergiou, G. S. (2020) · Updates in Hypertension and Cardiovascular Protection · doi:10.1007/978-3-030-23065-4_13 · Cited by 5
Self-citation
Metadata
- Authors
- Stergiou, G. S., Yiannes, N. G., & Rarra, V. C.
- Venue
- Blood Pressure Monitoring
- Published
- 2006-08
- Volume
- 11
- Issue
- 4
- Pages
- 229-234
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W1975069589
- Cited by
- 192
- References
- 12
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›