Preservation of Hearing in Cochlear Implant Surgery: Advantages of Combined Electrical and Acoustical Speech Processing
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVES/HYPOTHESIS: This study documents the importance of preserving residual low-frequency acoustic hearing as those with more residual hearing are selected for cochlear implantation. Surgical strategies used for hearing preservation with a short hybrid cochlear implant are outlined. The benefits of preserved residual low-frequency hearing, improved word understanding in noise, and music appreciation are described. STUDY DESIGN: Multicenter, prospective, single-subject design. METHODS: Records were reviewed of 21 individuals participating in an Food and Drug Administration (FDA) feasibility clinical trial who have received an Iowa/Nucleus 10 mm electrode. A second group of subjects receiving implants at the University of Iowa that have used the 10 mm device between 2 years and 6 months were also reviewed. Outcome measures included standardized tests of monosyllabic word understanding, spondees in noise, and common melody recognition. RESULTS: Low-frequency hearing was maintained in all individuals immediately postoperative. One subject lost hearing at 2.5 months postoperative after a viral infection. The group has averaged a loss of -9 dB low-frequency acoustic hearing between 125 and 1,000 Hz. Monosyllabic word understanding scores at 6 months for a group being followed for an FDA clinical trial using the implant plus hearing aids was 69% correct. For the long-term group receiving implants at Iowa, monosyllabic word understanding in those who have used the device between 6 months and 2 years is 79%. Other important findings include improved recognition of speech in noise (9 dB improvement) as compared with standard cochlear implant recipients who were matched for speech recognition in quiet and near normal recognition of common melodies. CONCLUSION: The surgical strategies outlined have been successful in preservation of low-frequency hearing in 96% of individuals. Combined electrical and acoustical speech processing has enabled this group of volunteers to gain improved word understanding as compared with their preoperative hearing with bilateral hearing aids and a group of individuals receiving a standard cochlear implant with similar experience with their device. The improvement of speech in noise and melody recognition is attributed to the ability to distinguish fine pitch differences as the result of preserved residual low-frequency acoustic hearing. Preservation of low-frequency acoustic hearing is important for improving speech in noise and music appreciation for the hearing impaired, both of which are important in real-life situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A cochlear frequency-position function for several species—29 years later
Greenwood, D. D. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399052 · Cited by 1,890
Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Fu, Q., Shannon, R. V., & Wang, X. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423941 · Cited by 388
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Self-citationMusic Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Self-citationCochlear implant speech recognition with speech maskers
Stickney, G. S., Zeng, F.-G., Litovsky, R., & Assmann, P. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1772399 · Cited by 340
Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant
Gantz, B. J., & Turner, C. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016423 · Cited by 204
Self-citation
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“the same ear, particularly in the presence of noise [129], [132], [133].”
BackgroundCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Self-citationImpact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
Metadata
- Authors
- Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2005-05
- Volume
- 115
- Issue
- 5
- Pages
- 796-802
- ISSN
- 0023-852X (ISSN-L)
- OpenAlex
- W2149904637
- Cited by
- 502
- References
- 9
- FWCI
- 14.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.