Multichannel Cochlear Implants: Relation of Histopathology to Performance
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Objectives: To determine the relationship of surviving neural elements to auditory function in multichannel cochlear implant temporal bones. Study Design: Case series of all 14 existing multichannel cochlear implants in our temporal bone collection. Methods: Devices included Nucleus 22 (n = 11), Nucleus 24 (n = 1), Ineraid (n = 1), and Clarion (n = 1). Morphologic evaluation of structural elements including spiral ligament, stria vascularis, hair cells, peripheral processes, and spiral ganglion cells was performed. Clinical performance data were obtained from patient charts. For eight patients, nonimplanted contralateral temporal bones were available and paired comparisons were made. Results: Despite frequent absence of hair cells and peripheral processes, all bones had at least some remaining spiral ganglion cells. Percent of normal remaining structures were unrelated to auditory performance with the implant for any of the structural elements. Ganglion cell count in segment III showed significant negative correlations to speech discrimination scores for words and sentences (Rhos = −.687 and −.661, P ≤ .03 and .04) as did segment IV and total ganglion cell count with word score (Rhos = −.632 and −.638; P ≤ .05). Spiral ganglion cell survival did not differ between implanted and nonimplanted ears, with the exception of segment I, which had fewer cells in the implanted ear (P ≤ .028). Conclusions: Performance variability of cochlear implants cannot be explained on the basis of cochlear neuronal survival. Although hair cells and peripheral processes were frequently absent or greatly diminished from normal, all subjects had at least some spiral ganglion cells. And, in this series, there was an inverse relationship between survival of ganglion cells and performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods for the Counting of Neurons
Konigsmark, B. W. (1970) · Contemporary Research Methods in Neuroanatomy · doi:10.1007/978-3-642-85986-1_14 · Cited by 763
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Otte, J., Schuknecht, H. F., & Kerr, A. G. (1978) · The Laryngoscope · doi:10.1288/00005537-197808000-00004 · Cited by 486
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
NADOLJR, J. (1997) · Otolaryngology - Head and Neck Surgery · doi:10.1016/s0194-5998(97)70178-5 · Cited by 359
Clinical differentiation of conductive hearing loss
Stroud, M. H. (1978) · The Laryngoscope · doi:10.1288/00005537-197808000-00002 · Cited by 293
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs
Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003) · The Laryngoscope · doi:10.1097/00005537-200303000-00005 · Cited by 257
Xu, J., Shepherd, R. K., Millard, R. E., & Clark, G. M. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00193-1 · Cited by 242
Skinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 223
Ketten, D. R., Skinner, M. W., Wang, G., Vannier, M. W., Gates, G. A., & Neely, J. G. (1998) · PubMed · Cited by 222
Adunka, O., Kiefer, J., Unkelbach, M. H., Lehnert, T., & Gstoettner, W. (2004) · The Laryngoscope · doi:10.1097/00005537-200407000-00018 · Cited by 184
PYMAN, B., BLAMEY, P., LACY, P., CLARK, G., & DOWELL, R. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80076-9 · Cited by 165
Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea
Frijns, J. H. M., de Snoo, S. L., & ten Kate, J. H. (1996) · Hearing Research · doi:10.1016/0378-5955(96)00004-4 · Cited by 161
Cochlear implant histopathology.
Linthicum, F. H., Fayad, J. N., Otto, S. R., Galey, F. R., & House, W. F. (1991) · PubMed · Cited by 143
Self-citationComparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112
Pattern of degeneration of the spiral ganglion cell and its processes in the C57BL/6J mouse
White, J. A., Burgess, B. J., Hall, R. D., & Nadol, J. B. (2000) · Hearing Research · doi:10.1016/s0378-5955(99)00204-x · Cited by 110
Clark, G. M., Shepherd, R. K., Franz, B. K.-H. G., Dowell, R. C., Tong, Y. C., Blamey, P. J., Webb, R. L., Pyman, B. C., McNaughtan, J., Bloom, D. M., et al. (1988) · Acta Oto-Laryngologica · doi:10.3109/00016488809098972 · Cited by 80 · cited 1×
“Only one subject (5) had hair cells remaining in the TABLE III.”
BackgroundInsertional trauma of multichannel cochlear implants
Welling, D. B., Hinojosa, R., Gantz, B. J., & Lee, J. (1993) · The Laryngoscope · doi:10.1288/00005537-199309000-00010 · Cited by 75
Multielectrode Intracochlear Implants
Schindler, R. A., Merzenich, M. M., White, M. W., & Bjorkroth, B. (1977) · Archives of Otolaryngology · doi:10.1001/archotol.1977.00780290027001 · Cited by 75
Histopathology of human cochlear implants: Correlation of psychophysical and anatomical measures
Khan, A. M., Whiten, D. M., Nadol, J. B., & Eddington, D. K. (2005) · Hearing Research · doi:10.1016/j.heares.2005.03.003 · Cited by 59
The Clarion electrode positioner: Temporal bone studies
Fayad, J. N., Luxford, W. M., & Linthicum, F. H. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80013-7 · Cited by 47
Self-citation
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons
Richardson, R. T., Wise, A. K., Thompson, B. C., Flynn, B. O., Atkinson, P. J., Fretwell, N. J., Fallon, J. B., Wallace, G. G., Shepherd, R. K., Clark, G. M., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.015 · Cited by 304
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“6) of the dynamics of insertion, helped to improve the surgical techniques used by the surgeons to improve the design of the CI electrodes (Roland et al., 2000; Balkany et al., 2003; Eshraghi et al., 2004; Fayad and Linthicum, 2006).”
MethodPathophysiological mechanisms and functional hearing consequences of auditory neuropathy
Rance, G., & Starr, A. (2015) · Brain · doi:10.1093/brain/awv270 · Cited by 212
“…form of auditory neuropathy have consistently shown good cochlear implant outcomes, reflecting the fact that direct electrical stimulation up to the level of the spiral ganglion bypasses the peripheral sensory system (Clopton et al ., 1980; Linthicum et al ., 1991; Fayad and Linthicum, 2006).”
Metadata
- Authors
- Fayad, J. N., & Linthicum, F. H.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2006-08
- Volume
- 116
- Issue
- 8
- Pages
- 1310-1320
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2029973746
- Cited by
- 222
- References
- 23
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.