Intracytoplasmic tagging of cells with ferumoxides and transfection agent for cellular magnetic resonance imaging after cell transplantation: methods and techniques
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Superparamagnetic iron oxides (SPIO) are being used to label cells for in vivo monitoring by magnetic resonance imaging (MRI). The purpose of this study is to present protocols using SPIO and a polycationic transfection agent for magnetic labeling of cells as a basis for cellular MRI. METHODS: Various concentrations of ferumoxides (FE)-poly-l-lysine (PLL) complexes were used to magnetically label cells. Iron incorporation into cells along with cell viability and short- and long-term toxicity were evaluated. RESULTS: Rapidly growing cell suspension and adherent cells were effectively labeled by means of endocytosis into endosomes at low concentrations of FE (25 microg/mL media) and PLL (0.75 microg/mL media). Hematopoietic stem cells and lymphocytes required higher concentrations of PLL (1.5 microg/mL) in serum-free media during initial FE-PLL complex formation before labeling the cells in culture. Total iron concentration in cells depended on the cell type, concentration of FE-PLL complexes in media, cellular density, and incubation time. Iron concentrations after overnight incubation with given FE at 25 microg/mL media resulted in, for example, T cells being labeled with 1 to 3 pg/cell of intracytoplasmic endosomal iron and 15 to 20 pg/cell of intracytoplasmic iron in mesenchymal stem cells compared with 0.01 to 0.1 pg/cell for unlabeled cells. Protocols developed for this study demonstrated no adverse effect on the cell viability, functional capacity, or toxicity. CONCLUSION: This technique can be used to label cells for in vivo MRI tracking of stem cells and lymphocytes. FE at a concentration of 25 to 50 microg/mL with a ratio of SPIO to PLL of 1:0.03 to 1:0.06 would be sufficient to label cells for cellular MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage potential of adult human mesenchymal stem cells
Pittenger, M. F., Mackay, A. M., Beck, S. C., Jaiswal, R. K., Douglas, R., Mosca, J. D., Moorman, M. A., Simonetti, D. W., Craig, S., & Marshak, D. R. (1999) · Science · doi:10.1126/science.284.5411.143 · Cited by 21,052
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Derivation of pluripotent stem cells from cultured human primordial germ cells
Shamblott, M. J., Axelman, J., Wang, S., Bugg, E. M., Littlefield, J. W., Donovan, P. J., Blumenthal, P. D., Huggins, G. R., & Gearhart, J. D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13726 · Cited by 1,420
Deans, R. J., & Moseley, A. B. (2000) · Experimental Hematology · doi:10.1016/s0301-472x(00)00482-3 · Cited by 1,412
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Self-citationHigh-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
In vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Hoehn, M., Küstermann, E., Blunk, J., Wiedermann, D., Trapp, T., Wecker, S., Föcking, M., Arnold, H., Hescheler, J., Fleischmann, B. K., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.242435499 · Cited by 707
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Self-citation
Cited by
Interaction of Nanoparticles with Cells
Mailänder, V., & Landfester, K. (2009) · Biomacromolecules · doi:10.1021/bm900266r · Cited by 576
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
Self-citationLiu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Kostura, L., Kraitchman, D. L., Mackay, A. M., Pittenger, M. F., & Bulte, J. W. M. (2004) · NMR in Biomedicine · doi:10.1002/nbm.925 · Cited by 429
Self-citationNanotechnology, nanotoxicology, and neuroscience
Suh, W. H., Suslick, K. S., Stucky, G. D., & Suh, Y.-H. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.09.009 · Cited by 406
Arbab, A. S., Wilson, L. B., Ashari, P., Jordan, E. K., Lewis, B. K., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.970 · Cited by 347
Self-citationIron-Oxide Labeling and Outcome of Transplanted Mesenchymal Stem Cells in the Infarcted Myocardium
Amsalem, Y., Mardor, Y., Feinberg, M. S., Landa, N., Miller, L., Daniels, D., Ocherashvilli, A., Holbova, R., Yosef, O., Barbash, I. M., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.680231 · Cited by 324
Song, H.-T., Choi, J.-S., Huh, Y.-M., Kim, S., Jun, Y.-W., Suh, J.-S., & Cheon, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja051833y · Cited by 304
Arbab, A. S., Yocum, G. T., Rad, A. M., Khakoo, A. Y., Fellowes, V., Read, E. J., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.991 · Cited by 297
“on iron-sensitive T2-weighted and T2*-weighted gradient echo images [2,3,5–14].”
BackgroundSelf-citation19F MRI for quantitative in vivo cell tracking
Srinivas, M., Heerschap, A., Ahrens, E. T., Figdor, C. G., & Vries, I. J. M. D. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.04.002 · Cited by 285
Terrovitis, J., Stuber, M., Youssef, A., Preece, S., Leppo, M., Kizana, E., Schär, M., Gerstenblith, G., Weiss, R. G., Marbán, E., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.732073 · Cited by 268
Barrett, T., Brechbiel, M., Bernardo, M., & Choyke, P. L. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20991 · Cited by 266
Anderson, S. A., Glod, J., Arbab, A. S., Noel, M., Ashari, P., Fine, H. A., & Frank, J. A. (2005) · Blood · doi:10.1182/blood-2004-06-2222 · Cited by 254
Self-citationTargeted contrast agents for magnetic resonance imaging and ultrasound
Morawski, A. M., Lanza, G. A., & Wickline, S. A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.11.001 · Cited by 224
Arbab, A. S., Yocum, G. T., Wilson, L. B., Parwana, A., Jordan, E. K., Kalish, H., & Frank, J. A. (2004) · Molecular Imaging · doi:10.1162/15353500200403190 · Cited by 214
“Cell Proliferative Activity and Viability Proliferative activity and viability of FE/TA labeled or TA treated cells were evaluated using an MTT (3-[4,5-2yl]-2,5-diphenyl tetrazolium bromide) assay (Roche Molecular Biochemicals, Indianapolis, IN) and Trypan blue dye exclusion test, respectively, as described previously…”
MethodSelf-citationQuantitative analysis of the protein corona on FePt nanoparticles formed by transferrin binding
Jiang, X., Weise, S., Hafner, M., Röcker, C., Zhang, F., Parak, W. J., & Nienhaus, G. U. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0272.focus · Cited by 212
In Vivo Trafficking and Targeted Delivery of Magnetically Labeled Stem Cells
Arbab, A. S., Jordan, E. K., Wilson, L. B., Yocum, G. T., Lewis, B. K., & Frank, J. A. (2004) · Human Gene Therapy · doi:10.1089/104303404322959506 · Cited by 176
“The iron concentration in the solution was measured by NMR relaxometry and normalized to standard as described previously (Bulte et al ., 2001; Frank et al ., 2003; Arbab et al ., 2003a,b).”
InfluentialSelf-citationPreparation of Magnetically Labeled Cells for Cell Tracking by Magnetic Resonance Imaging
Bulte, J. W. M., Arbab, A. S., Douglas, T., & Frank, J. A. (2004) · Methods in Enzymology · doi:10.1016/s0076-6879(04)86013-0 · Cited by 175
Self-citationArbab, A. S., Frenkel, V., Pandit, S. D., Anderson, S. A., Yocum, G. T., Bur, M., Khuu, H. M., Read, E. J., & Frank, J. A. (2006) · Stem Cells · doi:10.1634/stemcells.2005-0017 · Cited by 167
Self-citationDaldrup-Link, H. E., Meier, R., Rudelius, M., Piontek, G., Piert, M., Metz, S., Settles, M., Uherek, C., Wels, W., Schlegel, J., et al. (2005) · European Radiology · doi:10.1007/s00330-004-2526-7 · Cited by 167
“This is in accordance with data from the literature (17, 20, 22, 25, 40-42).”
ResultSynthesis and characterization of magnetite nanoparticles coated with lauric acid
Mamani, J. B., Costa-Filho, A. J., Cornejo, D. R., Vieira, E. D., & Gamarra, L. F. (2013) · Materials Characterization · doi:10.1016/j.matchar.2013.04.001 · Cited by 116
“[49] Arbab AS, Bashaw LA, Miller BR, Jordan EK, Bulte JW, Frank JA.”
BackgroundSchmidtke-Schrezenmeier, G., Urban, M., Musyanovych, A., Mailänder, V., Rojewski, M., Fekete, N., Menard, C., Deak, E., Tarte, K., Rasche, V., et al. (2011) · Cytotherapy · doi:10.3109/14653249.2011.571246 · Cited by 34
Wang, Y. J., Leung, K. C., Cheung, W., Wang, H., Shi, L., Wang, D., Qin, L., & Ahuja, A. T. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22173 · Cited by 29
Metadata
- Authors
- Arbab, A. S., Bashaw, L. A., Miller, B. R., Jordan, E. K., Bulte, J. W. M., & Frank, J. A.
- Venue
- Transplantation
- Published
- 2003-10-15
- Volume
- 76
- Issue
- 7
- Pages
- 1123-1130
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2031783970
- Cited by
- 253
- References
- 25
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.