CoChat

Variation of Arterial and Central Venous Catheter Use in United States Intensive Care Units

Open access
Gershengorn, Hayley B., Garland, Allan, Kramer, Andrew, Scales, Damon C., Rubenfeld, Gordon, Wunsch, Hannah · 2014 · Anesthesiology
Cited by 121

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Arterial catheters (ACs) and central venous catheters (CVCs) are common in intensive care units (ICUs). Few data describe which patients receive these devices and whether variability in practice exists. Methods: The authors conducted an observational cohort study on adult patients admitted to ICU during 2001–2008 by using Project IMPACT to determine whether AC and CVC use is consistent across U.S. ICUs. The authors examined trends over time and patients more (mechanically ventilated or on vasopressors) or less (predicted risk of hospital mortality ≤2%) likely to receive either catheter. Results: Our cohort included 334,123 patients across 122 hospitals and 168 ICUs. Unadjusted AC usage rates remained constant (36.9% [2001] vs. 36.4% [2008]; P = 0.212), whereas CVC use increased (from 33.4% [2001] to 43.8% [2008]; P < 0.001 comparing 2001 and 2008); adjusted AC usage rates were constant from 2004 (35.2%) to 2008 (36.4%; P = 0.43 for trend). Surgical ICUs used both catheters most often (unadjusted rates, ACs: 56.0% of patients vs. 22.4% in medical and 32.6% in combined units, P < 0.001; CVCs: 46.9% vs. 32.5% and 36.4%, P < 0.001). There was a wide variability in AC use across ICUs in patients receiving mechanical ventilation (median [interquartile range], 49.2% [29.9–72.3%]; adjusted median odds ratio [AMOR], 2.56), vasopressors (51.7% [30.8–76.2%]; AMOR, 2.64), and with predicted mortality of 2% or less (31.7% [19.5–49.3%]; AMOR, 1.94). There was less variability in CVC use (mechanical ventilation: 63.4% [54.9–72.9%], AMOR, 1.69; vasopressors: 71.4% (59.5–85.7%), AMOR, 1.93; predicted mortality of 2% or less: 18.7% (11.9–27.3%), AMOR, 1.90). Conclusions: Both ACs and CVCs are common in ICU patients. There is more variation in use of ACs than CVCs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000000008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 121

Metadata

Authors
Gershengorn, H. B., Garland, A., Kramer, A., Scales, D. C., Rubenfeld, G., & Wunsch, H.
Venue
Anesthesiology
Published
2014-03
Volume
120
Issue
3
Pages
650-664
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2061149030
Cited by
121
References
2
FWCI
5.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variation of Arterial and Central Venous Catheter Use in United States Intensive Care Units. https://app.cochat.ai/papers/10.1097/aln.0000000000000008
The paper
Gershengorn, H. B., Garland, A., Kramer, A., Scales, D. C., Rubenfeld, G., & Wunsch, H. (2014). Variation of Arterial and Central Venous Catheter Use in United States Intensive Care Units. Anesthesiology. https://doi.org/10.1097/aln.0000000000000008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.