Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure: A Systematic Review and Meta-analysis

Open access
Kim, Sang-Hyun, Lilot, Marc, Sidhu, Kulraj S., Rinehart, Joseph, Yu, Zhaoxia, Canales, Cecilia, Cannesson, Maxime · 2014 · Anesthesiology
Cited by 207

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

Background: Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. Methods: The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. Results: Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were −1.6 ± 12.2 mmHg (95% limits of agreement −25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (−11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (−13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were −1.8 ± 12.4 mmHg (−26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (−10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (−13.1 to 21.0 mmHg) for mean arterial pressure. Conclusions: The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000000226

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Cited by

See all 207

Metadata

Authors
Kim, S.-H., Lilot, M., Sidhu, K. S., Rinehart, J., Yu, Z., Canales, C., & Cannesson, M.
Venue
Anesthesiology
Published
2014-05
Volume
120
Issue
5
Pages
1080-1097
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2083960157
Cited by
207
References
59
FWCI
16.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1097/aln.0000000000000226
The paper
Kim, S.-H., Lilot, M., Sidhu, K. S., Rinehart, J., Yu, Z., Canales, C., & Cannesson, M. (2014). Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure: A Systematic Review and Meta-analysis. Anesthesiology. https://doi.org/10.1097/aln.0000000000000226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.