Accuracy of Transthoracic Lung Ultrasound for Diagnosing Anesthesia-induced Atelectasis in Children
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Background: The aim of this study was to test the accuracy of lung sonography (LUS) to diagnose anesthesia-induced atelectasis in children undergoing magnetic resonance imaging (MRI). Methods: Fifteen children with American Society of Anesthesiology’s physical status classification I and aged 1 to 7 yr old were studied. Sevoflurane anesthesia was performed with the patients breathing spontaneously during the study period. After taking the reference lung MRI images, LUS was carried out using a linear probe of 6 to 12 MHz. Atelectasis was documented in MRI and LUS segmenting the chest into 12 similar anatomical regions. Images were analyzed by four blinded radiologists, two for LUS and two for MRI. The level of agreement for the diagnosis of atelectasis among observers was tested using the κ reliability index. Results: Fourteen patients developed atelectasis mainly in the most dependent parts of the lungs. LUS showed 88% of sensitivity (95% CI, 74 to 96%), 89% of specificity (95% CI, 83 to 94%), and 88% of accuracy (95% CI, 83 to 92%) for the diagnosis of atelectasis taking MRI as reference. The agreement between the two radiologists for diagnosing atelectasis by MRI was very good (κ, 0.87; 95% CI, 0.72 to 1; P < 0.0001) as was the agreement between the two radiologists for detecting atelectasis by LUS (κ, 0.90; 95% CI, 0.75 to 1; P < 0.0001). MRI and LUS also showed good agreement when data from the four radiologists were pooled and examined together (κ, 0.75; 95% CI, 0.69 to 0.81; P < 0.0001). Conclusion: LUS is an accurate, safe, and simple bedside method for diagnosing anesthesia-induced atelectasis in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068
A trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Lichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Pulmonary Densities during Anesthesia with Muscular Relaxation—A Proposal of Atelectasis
Brismar, B., Hedenstierna, G., Lundquist, H., Strandberg, Å., Svensson, L., & Tokics, L. (1985) · Anesthesiology · doi:10.1097/00000542-198504000-00009 · Cited by 582 · cited 2×
“As LUS provides regional information, we repeated the following examination sequence in each hemithorax and in all patients: (1) anterior, (2) lateral, and (3) posterior regions starting from the diaphragm (caudal lung) and moving toward the apex (cranial lung).”
MethodUltrasound diagnosis of alveolar consolidation in the critically ill
Lichtenstein, D. A., Lascols, N., Mezière, G., & Gepner, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2075-6 · Cited by 512
Lung ultrasound in critically ill patients: comparison with bedside chest radiography
Xirouchaki, N., Magkanas, E., Vaporidi, K., Kondili, E., Plataki, M., Patrianakos, A., Akoumianaki, E., & Georgopoulos, D. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2317-y · Cited by 474
Lichtenstein, D., Mezière, G., & Seitz, J. (2009) · Chest · doi:10.1378/chest.08-2281 · Cited by 429
Ultrasound assessment of antibiotic-induced pulmonary reaeration in ventilator-associated pneumonia*
Bouhemad, B., Liu, Z., Arbelot, C., Zhang, M., Ferarri, F., Guen, M. L., Girard, M., Lü, Q., & Rouby, J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b08cdb · Cited by 386
The “lung pulse”: an early ultrasound sign of complete atelectasis
Lichtenstein, D. A., Lascols, N., Prin, S., & Mezière, G. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1930-9 · Cited by 372
Lung Ultrasound in Respiratory Distress Syndrome: A Useful Tool for Early Diagnosis
Copetti, R., Cattarossi, L., Macagno, F., Violino, M., & Furlan, R. (2008) · Neonatology · doi:10.1159/000113059 · Cited by 287
The ‘Double Lung Point’: An Ultrasound Sign Diagnostic of Transient Tachypnea of the Newborn
Copetti, R., & Cattarossi, L. (2007) · Neonatology · doi:10.1159/000097454 · Cited by 260
INFLUENCE OF AGE ON ATELECTASIS FORMATION AND GAS EXCHANGE IMPAIRMENT DURING GENERAL ANAESTHESIA
GUNNARSSON, L., TOKICS, L., GUSTAVSSON, H., & HEDENSTIERNA, G. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/66.4.423 · Cited by 253
The Reliability of Dichotomous Judgments: Unequal Numbers of Judges per Subject
Fleiss, J. L., & Cuzick, J. (1979) · Applied Psychological Measurement · doi:10.1177/014662167900300410 · Cited by 191
Hauser, G. J., Ben‐Ari, J., Colvin, M. P., Dalton, H. J., Hertzog, J. H., Bearb, M. E., Hopkins, R. A., & Walker, S. M. (1998) · Intensive Care Medicine · doi:10.1007/s001340050600 · Cited by 97
Pediatric pulmonary CT-scanning: Anaesthesia-induced changes
Damgaard-Pedersen, K., & Qvist, T. (1980) · Pediatric Radiology · doi:10.1007/bf01464308 · Cited by 81
Atelectasis on pediatric chest CT: comparison of sedation techniques
Sargent, M. A., McEachern, A. M., Jamieson, D. H., & Kahwaji, R. (1999) · Pediatric Radiology · doi:10.1007/s002470050632 · Cited by 56
Using sonography to assess lung recruitment in patients with acute respiratory distress syndrome
Gardelli, G., Feletti, F., Gamberini, E., Bonarelli, S., Nanni, A., & Mughetti, M. (2008) · Emergency Radiology · doi:10.1007/s10140-008-0734-1 · Cited by 36
Cited by
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Gargani, L., & Volpicelli, G. (2014) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-12-25 · Cited by 381
Quantitative Lung Ultrasound: Technical Aspects and Clinical Applications
Mongodi, S., De Luca, D., Colombo, A., Stella, A., Santangelo, E., Corradi, F., Gargani, L., Rovida, S., Volpicelli, G., Bouhemad, B., et al. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003757 · Cited by 242
“lung sliding with the presence of the lung pulse) accurately identified anesthesia-induced atelectasis, assessed by magnetic resonance imaging.(77) Although randomized clinical trials have given variable results, it has been suggested that to limit volutrauma and reduce atelectrauma and thus prevent postoperative comp…”
BackgroundPerioperative Pulmonary Atelectasis: Part II. Clinical Implications
Lagier, D., Zeng, C., Fernandez-Bustamante, A., & Vidal Melo, M. F. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004009 · Cited by 182
Lung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001603 · Cited by 181
Metadata
- Authors
- Acosta, C. M., Maidana, G. A., Jacovitti, D., Belaunzarán, A., Cereceda, S., Rae, E., Molina, A., Gonorazky, S., Bohm, S. H., & Tusman, G.
- Venue
- Anesthesiology
- Published
- 2014-06
- Volume
- 120
- Issue
- 6
- Pages
- 1370-1379
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1965665085
- Cited by
- 190
- References
- 21
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.