Ultrasound for “Lung Monitoring” of Ventilated Patients
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In the intensive care unit, patient lung ultrasound provides accurate information on lung morphology with diagnostic and therapeutic relevance. It enables clinicians easy, rapid, and reliable evaluation of lung aeration and its variations at the bedside. Supplemental Digital Content is available in the text.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Self-citationLung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548
Lichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
Clinical review: Bedside lung ultrasound in critical care practice.
Bouhemad, B., Zhang, M., Lü, Q., & Rouby, J. (2007) · Critical Care · doi:10.1186/cc5668 · Cited by 768
Self-citationGheorghiade, M., Follath, F., Ponikowski, P., Barsuk, J. H., Blair, J. E. A., Cleland, J. G., Dickstein, K., Drazner, M. H., Fonarow, G. C., Jaarsma, T., et al. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq045 · Cited by 739
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736
Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
Self-citationUltrasound diagnosis of occult pneumothorax*
Lichtenstein, D. A., Mezière, G., Lascols, N., Biderman, P., Courret, J.-P., Gepner, A., Goldstein, I., & Tenoudji-Cohen, M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000164542.86954.b4 · Cited by 632
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Copetti, R., Soldati, G., & Copetti, P. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-16 · Cited by 555
Cited by
Spectrum of Cardiac Manifestations in COVID-19: A Systematic Echocardiographic Study
Szekely, Y., Lichter, Y., Taieb, P., Banai, A., Hochstadt, A., Merdler, I., Gal Oz, A., Rothschild, E., Baruch, G., Peri, Y., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.047971 · Cited by 590
Lung Ultrasound for Critically Ill Patients
Mojoli, F., Bouhemad, B., Mongodi, S., & Lichtenstein, D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0236ci · Cited by 513
Self-citationChiumello, D., Mongodi, S., Algieri, I., Vergani, G. L., Orlando, A., Via, G., Crimella, F., Cressoni, M., & Mojoli, F. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003340 · Cited by 308
Self-citationLung ultrasound predicts clinical course and outcomes in COVID-19 patients
Lichter, Y., Topilsky, Y., Taieb, P., Banai, A., Hochstadt, A., Merdler, I., Gal Oz, A., Vine, J., Goren, O., Cohen, B., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06212-1 · Cited by 251
Quantitative Lung Ultrasound: Technical Aspects and Clinical Applications
Mongodi, S., De Luca, D., Colombo, A., Stella, A., Santangelo, E., Corradi, F., Gargani, L., Rovida, S., Volpicelli, G., Bouhemad, B., et al. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003757 · Cited by 242
“As a mirror of the air/fluid ratio in the pulmonary parenchyma, lung ultrasound can also help guide fluid resuscitation, avoiding the risks of harmful fluid overload on lung function.(4,44,46,47) Heart failure signs and symptoms become evident late, and their disappearance is not always linked to real improvement.”
BackgroundSelf-citationLung Ultrasonography for the Assessment of Perioperative Atelectasis: A Pilot Feasibility Study
Monastesse, A., Girard, F., Massicotte, N., Chartrand-Lefebvre, C., & Girard, M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001603 · Cited by 181
Modified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration
Mongodi, S., Bouhemad, B., Orlando, A., Stella, A., Tavazzi, G., Via, G., Iotti, G., Braschi, A., & Mojoli, F. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-120260 · Cited by 178
“Schlussfolgerung In nicht selektierten ICU-Patienten ist die Abweichung der Pleuralänge in Longitudinalschnitten hoch und eine fokale Koaleszenz tritt häufig auf.”
MethodInfluentialSelf-citationRecruitment Maneuvers and PEEP Titration
Hess, D. R. (2015) · Respiratory Care · doi:10.4187/respcare.04409 · Cited by 168
Metadata
- Authors
- Bouhemad, B., Mongodi, S., Via, G., & Rouquette, I.
- Venue
- Anesthesiology
- Published
- 2015-02
- Volume
- 122
- Issue
- 2
- Pages
- 437-447
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2089724159
- Cited by
- 317
- References
- 24
- FWCI
- 7.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.